Too many concurrent user sessions currently connected

Problem

When trying to start an emulator, the Charon log file reports a "Too many concurrent user sessions currently connected" message.

Solution

Steps

  1. Check the number of allowed sessions for this license from the license view utility and the ones actually used from the Sentinel Admin Control Center. To do so, open your browser and open the page http://localhost:1947/_int_/sessions.html
  2. Check that there is no running emulator process on the server using the license. This could be a background process.
  3. Check that the license is not used by another server. This can be the case for a network license (a network license can be a red USB dongle or a Software License).
  4. Check that the emulator is trying to access the correct license:
    • Define the license key id in the emulator parameters (configuration file) and/or
    • Restrict network license access by opening the Sentinel Admin Control Center and

Cloned software license

In case you have several network licenses on your network (reminder: Software Licenses are by default network licenses) and you have not restricted access to remote licenses either from the Sentinel Admin Control Center or by restricting the license key ids in the configuration file, Charon will try to connect to any available license on the network. If this license is already used (another emulator running on another server), the "Too many concurrent user sessions currently connected" message can be reported. This is logical but may not reflect the cause of the error. The problem can in fact come from the unavailability of the license installed locally on the server, either because it is not accessible (USB dongle) or because the software license is in cloned state.

(lightbulb) To check for cloned software licenses, open the Sentinel Admin Control Center/Sentinel Keys tab (http://localhost:1947/_int_/devices.html)

If the license is in cloned state, this means it has been invalidated following updates described in this article: Software Licensing restrictions

To solve the issue, you need to delete the software license as described here: Cloned Software License Removal, generate a new fingerprint and send us the C2V file and we will update your license.

Related articles



© Stromasys, 1999-2024  - All the information is provided on the best effort basis, and might be changed anytime without notice. Information provided does not mean Stromasys commitment to any features described.