CHARON-AXP and CHARON-VAX for Windows - no log file present in the current configuration

Problem

The CHARON Launcher reports the following error:

WARNING: no log file present in the current configuration

(info) This does not prevent the emulator from running

Solution

  • Check the path you've specified in the log file name is correct and the folder exists.
    .
  • If you have enabled log rotation, the final component of the "session log" parameter must be a directory, and it must not end with a backslash.

    Affected products version: CHARON-VAX and CHARON-AXP for Windows starting with version 4.6.

    Example:

    Incorrect syntaxCorrect syntax
    set session log = "C:\CHARON\Logs\"set session log = "C:\CHARON\Logs"



© Stromasys, 1999-2024  - All the information is provided on the best effort basis, and might be changed anytime without notice. Information provided does not mean Stromasys commitment to any features described.