Problem
<CTRL-P> keys combination is still active even if the "set OPA0 break_on=none
" is set in the configuration file
Affected CHARON products: CHARON-AXP and CHARON-VAX version 4.3 and up running OpenVMS. Tru64 virtual machines are not affected
Solution
Disable also <CTRL-P> at SRM level: shutdown your OpenVMS system if running, enter the commands described below, restart CHARON and boot your OpenVMS virtual machine.
|
The "power off" command is used to preserve the ROM settings
Related articles