Problem

<CTRL-P> keys combination is still active even if the "set OPA0 break_on=none" is set in the configuration file

(warning) Affected CHARON products: CHARON-AXP and CHARON-VAX version 4.3 and up running OpenVMS. Tru64 virtual machines are not affected

Solution

Disable also <CTRL-P> at SRM level: shutdown your OpenVMS system if running, enter the commands described below, restart CHARON and boot your OpenVMS virtual machine.

P00>>> set controlp off

P00>>> power off

(info) The "power off" command is used to preserve the ROM settings



© Stromasys, 1999-2025  - All the information is provided on the best effort basis, and might be changed anytime without notice. Information provided does not mean Stromasys commitment to any features described. 