Product Documentation and Knowledge Base - HomeDocumentation


Charon-VAXCharon-AXPCharon-PDPCharon-SSPCharon-PAR

Console

Table of Contents

Back to Table of Contents

General Description

CHARON-AXP offers a one- (OPA0) or two-port serial console, depending on the specified HP Alpha model. 

(info) The AlphaServer DS10, AlphaServer DS10L, AlphaServer DS15, AlphaServer 400, AlphaServer 800, AlphaServer 1000 and AlphaServer 1000A has an additional on-board serial line controller providing a serial line TTA0.

The regular console is already preloaded, so you need to specify just its mapping to the host resources, for example:

load physical_serial_line OPA0 line="COM1:"

In case of the TTA0 console the mapping looks like that:

load virtual_serial_line TTA0 port=10000
set COM2 line=TTA0

The first line specifies a mapping to a unique TCP/IP host port ("10000" in this example), while the second line connects this mapping (TTA0) to the on-board serial line controller having the name "COM2" in CHARON environment.

Refer to this section for details of mapping.

Back to Table of Contents

Console Parameters

CHARON-AXP console line TTA0 (COM2) has the following parameters:

(info) All the values in the following tables are case insensitive

communication

Parametercommunication
Type

Text string

Value
  • "ascii" - for connection to terminals  (default)

  • "binary" - for binary (packet) protocols, which are used mainly for communicating with PLCs

line

Parameterline
TypeIdentifier
Value

This parameter is used to connect a particular serial line mapping interface to the controller.

Example:

set COM2 line=TTA0

Example

set COM2 communication="binary"

 

Back to Table of Contents

Mapping Serial line controllers to system resources

Types of serial line mapping:

TypeFunction
physical_serial_line

This type of mapping associates a COM port on a host system with an emulated HP Alpha serial line controller virtual "line".

The COM port can be a physical hardware port or a logical COM port.

virtual_serial_lineThis type of mapping associates a network connection on the host system with an emulated HP Alpha serial line controller virtual "line"

Example:

load physical_serial_line TTA0


Back to Table of Contents

physical_serial_line

line

Parameterline
TypeText string
Value

A defined COM port on a host system in the form of "\\.\COMn" (or "COM<n>:")

Example:

set OPA0 line="\\.\COM1"

baud

Parameterbaud
TypeNumeric
Value

Forces the baud rate of the corresponding COM port to be a specified value.

The variety of supported values depends on the underlying physical communication resource (COM port). The most widely used values are: 300, 1200, 9600, 19200, 38400.

Example:

set OPA0 baud=38400

break_on

Parameterbreak_on
TypeText string
Value

Specifies what byte sequences received over the physical serial line will trigger a HALT command.

This parameter works only for the console line.

Specify the following values: "Ctrl-P", "Break" or "none" ("none" disables triggering a HALT condition).

If your guest operating system is OpenVMS in addition to "none" setting you have to set a specific console parameter "controlp" to "off" in the following way:

>>> set controlp off
>>> power off

The second line is to preserve the ROM settings.

Example:

set OPA0 break_on="Ctrl-P"

The default value is "Break".

(warning) This parameter can be specified only for COM1 (OPA0) console

stop_on

Parameterstop_on
TypeText string
Value

Specifies what byte sequences received over the physical serial line will trigger a STOP condition. The STOP condition causes CHARON-AXP to exit.

Specify the one of the following values: “F6” or “none” ("none" disables triggering a STOP condition).

Example:

set OPA0 stop_on="F6"

The default value is "none".

Setting "F6" triggers the STOP condition upon receipt of the "<ESC>[17~" sequence. Terminals usually send these sequences by pressing the F6 button

(warning) This parameter can be specified only for COM1 (OPA0) console

log

Parameterlog
TypeText string
Value

A string specifying a file name to store the content of the console sessions or a directory where the log files for each individual session will be stored.

If an existing directory is specified, CHARON-AXP automatically enables creation of individual log files, one for each session using the same scheme as used for the generation of the rotating log files. If the "log" parameter is omitted, CHARON-AXP does not create a console log.

Examples:

set OPA0 log="log.txt"
set OPA0 log="C:\Charon\Logs"

Only existing directory can be used as a value of the "log" parameter.

Example of mapping a console line to a host physical serial line

load physical_serial_line OPA0
set OPA0 line="\\.\COM1"

Back to Table of Contents

virtual_serial_line

host

Parameterhost
TypeText string
Value

A remote host’s IP address or hostname (and optionally a remote TCP/IP port number) for the virtual serial line connection. If omitted, the virtual serial line does not initiate a connection to the remote host and will listen for incoming connection requests.

Specify the value in the following form:

set OPA0 host="<host-name>[:<port-no>]"

If the "<port-no>" is not specified, the virtual serial line uses the TCP/IP port number specified by the "port" parameter (see below).

port

Parameterport
TypeNumeric
Value

The TCP/IP port number for the virtual serial line. A virtual serial line always listens on this port for incoming connection requests.

If multiple virtualized machines are running on a server, ensure the port number is unique across the platform.

application

Parameterapplication
TypeText string
Value

An application (a terminal emulator is assumed in most cases) to be started on initialization of this serial line emulation. The specified application startup string may contain all required parameters.

Example:

set OPA application = "putty.exe -load OPA0"

In this example the terminal emulator application: "putty" is started with the parameters "-load OPA0" telling it to load a specific saved session named "OPA0", (created separately) from the host registry.

The "application" parameter is often combined with a "port" parameter:

set TTA0 port = 10003 application = "putty.exe -load TTA1"

break_on

Parameterbreak_on
TypeText string
Value

Specifies what byte sequences received over a virtual serial line triggers a HALT command.

Specify one of the following values: "Ctrl-P", "Break" or "none" to disable triggering a HALT condition. The commands are case insensitive.

If your guest operating system is OpenVMS in addition to "none" setting you have to set a specific console parameter "controlp" to "off" in the following way:

>>> set controlp off
>>> power off 

The second line is to preserve the ROM settings.

Example:

set OPA0 break_on="Ctrl-P"

The default value is "Break".

(warning) This parameter can be specified only for COM1 (OPA0) console

stop_on

Parameterstop_on
TypeText string
Value

Specifies what byte sequences received over the virtual serial line will trigger a STOP condition. The STOP condition causes CHARON-AXP to exit.

Specify one of the following values: “F6” or “none” ("none" disables triggering a STOP condition). The commands are case insensitive.

Example:

set OPA0 stop_on="F6"

The default value is "none".

Setting "F6" triggers the STOP condition upon receipt of the "<ESC>[17~" sequence.

(warning) This parameter can be specified only for COM1 (OPA0) console

log

Parameterlog
TypeText string
Value

A string specifying the filename to store the content of the console sessions or a directory where log files for each individual session will be stored.

If an existing directory is specified, CHARON-AXP automatically enables the creation of individual log files, one for each session using the same scheme as used for the generation of the rotating log files. If the "log" parameter is omitted, CHARON-AXP does not create any console log.

Examples:

set OPA0 log="log.txt"
set OPA0 log="C:\Charon\Logs"

Only existing directory can be used as a value of the "log" parameter.

Example 1

Mapping a console line to a host TCP/IP port 10003 and starting a "Putty" terminal emulator with a configuration "OPA" directing it to connect to the port 10003:

load virtual_serial_line OPA0
set OPA port = 10003 application = "putty.exe -load OPA0"

Notes on "virtual_serial_line" options

 

  1. Use the combination of "port" and "host" parameters as follows to connect a 3rd party terminal emulator or similar program.

    load virtual_serial_line TTA0 host="192.168.1.1" port=10000

    In this example CHARON-AXP connects to port 10000 of a host with TCP/IP address "192.168.1.1" and at the same time it accepts connections on local port 10000.

         

  2. It is possible to specify a port on a remote host (note that CHARON always acts as a server). The syntax is:

    load virtual_serial_line TTA0 host="192.168.1.1:20000" port=10000

    In this example CHARON-AXP accepts connection on local port 10000 and connects to remote port 20000 of a host with TCP/IP address "192.168.1.1"

Note: the examples above are mainly used for inter-CHARON communications. They are used to connect CHARON-AXP to an application that communicates to CHARON-AXP as described below.

 

Example 2

Two CHARON systems connected to each other:

On host "A":

load virtual_serial_line TTA0 port=5500 host="B"

On host "B":

load virtual_serial_line TTA0 port=5500 host="A"

On these two hosts, executing CHARON-AXP, the two TTA0 lines connect to each other, thus creating a "serial" cable between the two emulated HP Alphas. The sequential order in which the instances of CHARON-AXP are started makes no difference.

Back to Table of Contents



© Stromasys, 1999-2024  - All the information is provided on the best effort basis, and might be changed anytime without notice. Information provided does not mean Stromasys commitment to any features described.