Console
Table of Contents
General Description
CHARON-AXP offers a one- (OPA0) or two-port serial console, depending on the specified HP Alpha model.
The AlphaServer DS10, AlphaServer DS10L, AlphaServer DS15, AlphaServer 400, AlphaServer 800, AlphaServer 1000 and AlphaServer 1000A has an additional on-board serial line controller providing a serial line TTA0.
The regular console is already preloaded, so you need to specify just its mapping to the host resources, for example:
load physical_serial_line OPA0 line="COM1:" |
In case of the TTA0 console the mapping looks like that:
|
The first line specifies a mapping to a unique TCP/IP host port ("10000" in this example), while the second line connects this mapping (TTA0) to the on-board serial line controller having the name "COM2" in CHARON environment.
Refer to this section for details of mapping.
CHARON emulated console supports only 80 symbols in one line.
Console Parameters
CHARON-AXP console line TTA0 (COM2) has the following parameters:
All the values in the following tables are case insensitive
communication
Parameter | communication |
---|---|
Type | Text string |
Value |
|
line
Parameter | line | |
---|---|---|
Type | Identifier | |
Value | This parameter is used to connect a particular serial line mapping interface to the controller. Example:
|
Example
set COM2 communication="binary" |
Mapping Serial line controllers to system resources
Types of serial line mapping:
Type | Function |
---|---|
physical_serial_line | This type of mapping associates a COM port on a host system with an emulated HP Alpha serial line controller virtual "line". The COM port can be a physical hardware port or a logical COM port. |
virtual_serial_line | This type of mapping associates a network connection on the host system with an emulated HP Alpha serial line controller virtual "line" |
Example:
load physical_serial_line TTA0 |
physical_serial_line
line
Parameter | line | |
---|---|---|
Type | Text string | |
Value | A defined COM port on a host system in the form of "\\.\COMn" (or "COM<n>:") Example:
|
baud
Parameter | baud | |
---|---|---|
Type | Numeric | |
Value | Forces the baud rate of the corresponding COM port to be a specified value. The variety of supported values depends on the underlying physical communication resource (COM port). The most widely used values are: 300, 1200, 9600, 19200, 38400. Example:
|
break_on
Parameter | break_on | ||
---|---|---|---|
Type | Text string | ||
Value | Specifies what byte sequences received over the physical serial line will trigger a HALT command. This parameter works only for the console line. Specify the following values: "Ctrl-P", "Break" or "none" ("none" disables triggering a HALT condition). If your guest operating system is OpenVMS in addition to "none" setting you have to set a specific console parameter "controlp" to "off" in the following way:
The second line is to preserve the ROM settings. Example:
The default value is "Break". This parameter can be specified only for COM1 (OPA0) console |
stop_on
Parameter | stop_on | |
---|---|---|
Type | Text string | |
Value | Specifies what byte sequences received over the physical serial line will trigger a STOP condition. The STOP condition causes CHARON Virtual Machine (VM) to exit. Specify the one of the following values: “F6” or “none” ("none" disables triggering a STOP condition). Example:
The default value is "none". Setting "F6" triggers the STOP condition upon receipt of the " This parameter can be specified only for COM1 (OPA0) console |
log
Parameter | log | ||
---|---|---|---|
Type | Text string | ||
Value | A string specifying a file name to store the content of the console sessions or a directory where the log files for each individual session will be stored. If an existing directory is specified, CHARON VM automatically enables creation of individual log files, one for each session using the same scheme as used for the generation of the rotating log files. If the "log" parameter is omitted, CHARON VM does not create a console log. Examples:
Only existing directory can be used as a value of the "log" parameter. |
log_file_size
Parameter | log_file_size | ||
---|---|---|---|
Type | Text string | ||
Value | If log rotation is enabled, the log_file_size parameter determines the log file size threshold at which the log is automatically rotated.
Examples:
Minimum log file size is 64K, maximum is 1G. Setting size less then 64K effectively makes the log file unlimited. |
Example of mapping a console line to a host physical serial line
|
virtual_serial_line
host
Parameter | host | |
---|---|---|
Type | Text string | |
Value | A remote host’s IP address or hostname (and optionally a remote TCP/IP port number) for the virtual serial line connection. If omitted, the virtual serial line does not initiate a connection to the remote host and will listen for incoming connection requests. Specify the value in the following form:
If the "<port-no>" is not specified, the virtual serial line uses the TCP/IP port number specified by the "port" parameter (see below). |
port
Parameter | port |
---|---|
Type | Numeric |
Value | The TCP/IP port number for the virtual serial line. A virtual serial line always listens on this port for incoming connection requests. If multiple virtualized machines are running on a server, ensure the port number is unique across the platform. |
application
Parameter | application | ||
---|---|---|---|
Type | Text string | ||
Value | An application (a terminal emulator is assumed in most cases) to be started on initialization of this serial line emulation. The specified application startup string may contain all required parameters. Example:
In this example the terminal emulator application: "putty" is started with the parameters "-load OPA0" telling it to load a specific saved session named "OPA0", (created separately) from the host registry. The "application" parameter is often combined with a "port" parameter:
|
break_on
Parameter | break_on | ||
---|---|---|---|
Type | Text string | ||
Value | Specifies what byte sequences received over a virtual serial line triggers a HALT command. Specify one of the following values: "Ctrl-P", "Break" or "none" to disable triggering a HALT condition. The commands are case insensitive. If your guest operating system is OpenVMS in addition to "none" setting you have to set a specific console parameter "controlp" to "off" in the following way:
The second line is to preserve the ROM settings. Example:
The default value is "Break". This parameter can be specified only for COM1 (OPA0) console |
stop_on
Parameter | stop_on | |
---|---|---|
Type | Text string | |
Value | Specifies what byte sequences received over the virtual serial line will trigger a STOP condition. The STOP condition causes CHARON VM to exit. Specify one of the following values: “F6” or “none” ("none" disables triggering a STOP condition). The commands are case insensitive. Example:
The default value is "none". Setting "F6" triggers the STOP condition upon receipt of the " This parameter can be specified only for COM1 (OPA0) console |
log
Parameter | log | ||
---|---|---|---|
Type | Text string | ||
Value | A string specifying the filename to store the content of the console sessions or a directory where log files for each individual session will be stored. If an existing directory is specified, CHARON VM automatically enables the creation of individual log files, one for each session using the same scheme as used for the generation of the rotating log files. If the "log" parameter is omitted, CHARON VM does not create any console log. Examples:
Only existing directory can be used as a value of the "log" parameter. |
log_file_size
Parameter | log_file_size | ||
---|---|---|---|
Type | Text string | ||
Value | If log rotation is enabled, the log_file_size parameter determines the log file size threshold at which the log is automatically rotated.
Examples:
Minimum log file size is 64K, maximum is 1G. Setting size less then 64K effectively makes the log file unlimited. |
Example 1
Mapping a console line to a host TCP/IP port 10003 and starting a "Putty" terminal emulator with a configuration "OPA" directing it to connect to the port 10003:
|
Notes on "virtual_serial_line" options
Use the combination of "port" and "host" parameters as follows to connect a 3rd party terminal emulator or similar program.
load virtual_serial_line TTA0 host="192.168.1.1" port=10000
In this example CHARON VM connects to port 10000 of a host with TCP/IP address "192.168.1.1" and at the same time it accepts connections on local port 10000.
It is possible to specify a port on a remote host (note that CHARON always acts as a server). The syntax is:
load virtual_serial_line TTA0 host="192.168.1.1:20000" port=10000
In this example CHARON VM accepts connection on local port 10000 and connects to remote port 20000 of a host with TCP/IP address "192.168.1.1"
Note: the examples above are mainly used for inter-CHARON communications. They are used to connect CHARON VM to an application that communicates to CHARON VM as described below.
Example 2
Two CHARON VMs connected to each other:
On host "A":
load virtual_serial_line TTA0 port=5500 host="B" |
On host "B":
load virtual_serial_line TTA0 port=5500 host="A" |
On these two hosts, executing CHARON VM, the two TTA0 lines connect to each other, thus creating a "serial" cable between the two emulated HP Alphas. The sequential order in which the CHARON VMs are started makes no difference.
© Stromasys, 1999-2024 - All the information is provided on the best effort basis, and might be changed anytime without notice. Information provided does not mean Stromasys commitment to any features described.