Finding the target "/dev/sg" device

Finding the target "/dev/sg" device

Table of Contents

General description

This section describes how to find proper "/dev/sg" device for CHARON mapping

Procedures of finding the target "/dev/sg" device

Method 1

Open a terminal console and issue:

# lsscsi -g

(info) If the "lsscsi" command is not installed on your system, use "yum install lsscsi" to make it available. If you cannot install "lsscsi", use method 2 or method 3 described below.

Output example1:

[0:0:0:0]    disk    VMware   Virtual disk     1.0   /dev/sda   /dev/sg0

[0:0:10:0]   tape    COMPAQ   SDLT320          5F5F  /dev/st0   /dev/sg9

[0:0:11:0]   tape    COMPAQ   SDLT320          5F5F  /dev/st1   /dev/sg10

[0:0:12:0]   mediumx COMPAQ   MSL5000 Series   0520  /dev/sch0  /dev/sg11

Output example2:

[0:0:0:0]    disk    VMware,  VMware Virtual S 1.0   /dev/sda   /dev/sg0

[4:0:0:0]    cd/dvd  NECVMWar VMware SATA CD01 1.00  /dev/sr0   /dev/sg1


Method 2

Open a terminal console and issue:

# cat /proc/scsi/sg/device_hdr; cat /proc/scsi/sg/devices

Output example:

host    chan    id      lun     type    opens   qdepth  bus    online
4       0       0       0       5       1       1       0      1
5       0       0       0       0       1       1       0      1

The fifth column ("type") value has the following correspondence:

ValueDevice
0Disk
1Tape
5CD-ROM
8Tape changer

The "N" in the "/dev/sgN" device is the line number (starting from 0) corresponding to the output provided by the commands above without taking the header into account so here "/dev/sg0" corresponds to the the CD-ROM.

Method 3

On a freshly booted system, issue the following command:

# dmesg | grep sg

The output will look like that:

[ 1.503622] sr 4:0:0:0: Attached scsi generic sg0 type 5
[ 1.780897] sd 5:0:0:0: Attached scsi generic sg1 type 0

(warning) This table lists all the devices, not only the real SCSI ones (SATA/IDE for example). CHARON supports only real SCSI devices.