Console

Console

Table of Contents

General Description

CHARON-AXP offers two-port serial console on all supported AXP models.

Example for OPA0 console ("COM1" port):

set COM1 alias=OPA0

When using the TTA0 console ("COM2" port):

set COM2 alias=TTA0

Refer to Mapping Serial line controllers to system resources for details of mapping.

General parameters

CHARON-AXP console lines COM1 and COM2 have the following parameters:

All the values in the following tables are case insensitive.

alias

Parameter

alias

Type

Identifier

Value

This parameter is used to set an useful name for COM1 or COM2 ports.  It can be any name, for example "Console1", but usually it is "OPA0" for COM1 and "TTA0" for COM2.

This name is logged in CHARON log file, it can also be used for parametrization in CHARON configuration file along with "COM1" and "COM2" identifiers.

The main purpose of this parameter is migration from old CHARON systems (which do not have the described implementation of consoles) to the current design, since it allows retaining the original name used for parametrization, since the rest of the parameters stay the same in both implementations.

If the "alias" parameter is not specified CHARON log file will miss the name for the given console, for example " : Connected. Remote 127.0.0.1:63516" will be displayed instead of "OPA0 : Connected. Remote 127.0.0.1:63516". So it is always recommended to specify the "alias" parameter.

Example:

set COM2 alias=TTA0

communication

Parameter

communication

Type

Text string

Value

  • "ascii" - for connection to terminals  (default)

  • "binary" - for binary (packet) protocols, which are used mainly for communicating with PLCs

baud

Parameter

baud

Type

Numeric

Value

Forces the baud rate of the corresponding TTY port to a specified value.The variety of supported values depends on the underlying physical communication resource (TTY port). The most widely used values are: 300, 1200, 9600, 19200, 38400.

Example:

set OPA0 baud=38400

break_on

Parameter

break_on

Type

Text string

Value

Specifies what byte sequences received over the physical serial line will trigger a HALT command.

This parameter works only for the console line.

Specify the following values: "Ctrl-P" , "Break" or "none" ("none" disables triggering a HALT condition).

If your guest operating system is OpenVMS in addition to "none" setting you have to set a specific console parameter "controlp" to "off" in the following way:

The second line is to preserve the ROM settings.

Example:

set OPA0 break_on="Ctrl-P"

The default value is "Break".

This parameter can be specified only for COM1 (OPA0) console



© Stromasys, 1999-2025  - All the information is provided on the best effort basis, and might be changed anytime without notice. Information provided does not mean Stromasys commitment to any features described. 
Need fast, reliable migration? We have done it countless times. Talk to an expert