Product Documentation and Knowledge Base - HomeDocumentation


Charon-VAXCharon-AXPCharon-PDPCharon-SSPCharon-PAR

Preferences

Description

This option allows the users to define the following settings:

  • Default editor for Character User Interface and Graphical User Interface with the selection mode, automatic or on demand. Automatic means the GUI will be preferred (if defined) if available otherwise the CUI editor will be used.
  • Continuous log view:
    • start or not when the virtual machine is started from the menu.
    • display or not a reminder to tell how to exit from the view (CTRL-C).
    • automatically stop the continuous log view when the virtual machine is started or stopped.
  • Out Of Memory killer settings. The following settings are used to prevent OOM Killer to kill the processes if the available memory is low.
    • Charon VM process killing prevention → if enabled, when displaying the list of Virtual Machines, a message will be displayed to confirm the running VM is protected against OOM Killer ("Protected/OOM Killer")
    • VM overcommit_memory value → we recommend settings this value to 2.
    • VM panic_on_oom:
      • if set to 0 / disabled (recommended) → the kernel will kill some rogue process, by calling oom_kill().
      • if set to 1 / enabled → the kernel panics when out-of-memory happens.
  • Semi-graphics enabled/disabled
  • Display guests separator: can be none, blank line or separation line (useful if more than one virtual machine is configured on the server)
  • Charon log monitoring (global):
    • if enabled (default), the Linux Toolkit will create a log monitoring service when adding a new virtual machine and will report warning & error messages plus messages related to license, etc...
    • if disabled, this service will not be created. This is useful if a monitoring software monitors the Charon log files and the license driver processes
  • Charon guest service: define the default start and stop timeout for newly created virtual machines (Red Hat Enterprise Linux/CentOS 7 & 8 only).

Example