Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: layout reviewed / PDF export

...

  • Dynamically allocation (retranslation) of new created SAN LUN to virtual Alpha configuration
  • Scan and translation of SAN LUN parameters to virtual Alpha’s KGPSA DGxx: virtual drive parameters
  • Propagation of SAN LUN size change to virtual Alpha’s KGPSA virtual drive parameters
  • Automatically deallocation from virtual Alpha deleted SAN LUN
Div
classpagebreak


Example of configuration:

...

The ID number specified in the example above is a storage (for example SAN) controller path ID. This ID can be obtained from the "Host Device Check" utility ("Storage Controllers" section):

...

...

Once specified, all the disks attached to the storage are automatically mapped as disk units to CHARON VM.

...

P00>>>fc show devices
     UDID:110 WWID:01000010:6000-1fe1-000b-6bf0-0009-9081-1283-0081 (ev:none)
                                               via adapter     via fc_port         con
[0]                   pga0.0.0.5.1    5000-1fe1-000b-6bf1 yes (ev:none)
[1]                   pga0.0.0.5.1    5000-1fe1-000b-6bf4 yes (ev:none)
     UDID:108 WWID:01000010:6000-1fe1-000b-6bf0-0009-0440-4014-0039 (ev:none)
                                               via adapter     via fc_port         con
[12]                  pga0.0.0.5.1    5000-1fe1-000b-6bf1 yes (ev:none)
[13]                  pga0.0.0.5.1    5000-1fe1-000b-6bf4 yes (ev:none)

...

Configuration steps using FCMGR utility

...