Virtual machine creation fails with 'Can not find the most recent binary for emulator' message

Problem

When creating a virtual machine using the Charon Virtual Machine Manager interface, an error like the one below is reported:

Related products: Charon-AXP/VAX/PDP versions 4.8 and above for Windows

Solution

The software requires the correct "hw_model" parameter defined in the configuration file to find a match with the executable, in the example above the "as4000.exe" file.

The problem here is the hw_model value is incorrect as this value is case sensitive and the expected value is "AlphaServer_4000" and not "Alphaserver_4000". Solution is to update the configuration with the correct model name.

(info) These name are available from the user's guides, configuration details chapter then General settings.

Examples with Charon version 4.11:

Related articles



© Stromasys, 1999-2024  - All the information is provided on the best effort basis, and might be changed anytime without notice. Information provided does not mean Stromasys commitment to any features described.