Introduction

Contents

Description

When a Charon instance is stopped using the Charon tray icon, the Charon service management utility, Windows service management or the Virtual Machines Manager (depending on Charon version installed) or in case the Windows server is shutdown, it is like powering off a physical system without shutting it down first from the Charon emulated server point of view. In such a case, there is no clean shutdown of the legacy operating system (Tru64 or VMS). The services and applications are not stopped properly, and the file systems are not dismounted cleanly.

The Charon Instance Clean Shutdown Utility is designed to perform a clean shutdown of the emulated server before the Windows server power off occurs.

This document explains how to configure the utility and the methods that can be used to execute the remote shutdown. It relates to script versions 2.10 & 2.11.

Related products

  • CHARON-AXP on Windows, versions 4.8 and above
  • CHARON-VAX on Windows, versions 4.8 and above

Supported Guest Operating System versions

  • All VMS versions
  • All Tru64 versions

Supported Windows versions

This version of the utility has been validated on the following operating systems:

  • Windows Server 2008 R2
  • Windows Server 2012 R2
  • Windows Server 2016
  • Windows Server 2019
  • Windows 10

(info) PowerShell V5.1 or newer version is required.