General Settings

General Settings

Table of Contents

Session

General settings that control execution of CHARON-VAX belong to an object called "session". It is a preloaded object; therefore, only "set" commands apply. 

Example:

set session <parameter>=<value>

 

The following tables describe all available "session" parameters, their meaning and examples of usage:

hw_model

Parameter

hw_model

Type

Text string

Value

Virtual VAX system hardware model to be emulated.

Use a default configuration template for each particular model as a starting point for a custom configuration. This would ensure that the parameter is set correctly.

Exampleset session hw_model="VAX_6610"

The models are:

MicroVAX_3100_Model_96
MicroVAX_3100_Model_98
MicroVAX_3600
MicroVAX_3900
MicroVAX_II
VAXserver_3600
VAXserver_3600
VAXserver_3600_128
VAXserver_3600_512
VAXserver_3900
VAXserver_3900_128
VAXserver_3900_512
VAX_4000_Model_106
VAX_4000_Model_108
VAX_4000_Model_700
VAX_4000_Model_705
VAX_6000_Model_310
VAXstation_4000_Model_90
VAX_6610
VAX_6620
VAX_6630
VAX_6640

VAX_6650

VAX_6660

configuration_name

Parameter

configuration_name

Type

Text string

Value

Name of CHARON-VAX instance (unique):

set session configuration_name="MSCDV1"

The value of this parameter is used as prefix to the event log file name when multiple log files are configured (see below). From the example above, the CHARON-VAX log file will have the following name: MSCDV1-YYYY-MM-DD-hh-mm-ss-xxxxxxxxx.log

xxxxxxxxx is an increasing decimal number starting from 000000000 to separate log files with the same time of creation (in case the log is being written faster than one log file per second).

log

Parameter

log

Type

Text string

Value

The log file or directory name is where the log file for each CHARON-VAX execution session is stored.

Log specified as a file name

It is possible to overwrite the existing log file or to extend it using the "log_method" parameter.

(info) The "log_method" parameter is effective only when a single log file is specified, not a directory.

Example:

set session log="/charon/vax4106prod.log"

Log specified as a directory

CHARON-VAX automatically creates individual log files for each CHARON-VAX execution session. If the log parameter is omitted, CHARON-VAX creates a log file for each CHARON-VAX execution session in the directory where the emulator was started. In these two cases, the log rotation mode is enabled, meaning a new log file is created each time the virtual machine is started and when the log file size exceeds the one specified (see log_file_size) and/or when the log file is older than a specified number of days (see log_rotation_period).

(info) A symbolic link located in the same directory will be created, pointing to the active log file. Its name is based on the hw_model parameter or the configuration_name parameter if specified.

If the "configuration_name" parameter of the session is specified, the log file name is composed as follows:

<configuration_name>-YYYY-MM-DD-hh-mm-ss-xxxxxxxxx.log

If the "configuration_name" parameter is omitted, the log file name will have the following format:

<hw_model>-YYYY-MM-DD-hh-mm-ss-xxxxxxxxx.log

where "xxxxxxxxx" is an increasing decimal integer, starting from 000000000 to separate log files with the same time of creation (in case the log is being created faster than one log file per second).

(warning) Only existing directory can be specified. If the directory specified does not exist, this will be considered as a flat file.

Example:

set session configuration_name="vax4106prod"

set session log="/charon/logs"

The execution of the virtual machine will create a log file, named /charon/logs/vax4106prod-2016-10-13-10-00-00-000000000.log (for example) and a symbolic link named /charon/logs/vax4106prod.log pointing to this file. The link will be updated when the log rotation will occur.

(info) Starting with version 4.11 build 204-11, log file numbering is implemented when log rotating is used: when starting the Charon emulator the first log file name will be like <configuration_name>-YYYY-MM-DD-hh-mm-ss-xxxxxxxxx.log where xxxxxxxxx will be 000000000, this number will increase with each log rotation to make it easier to find a log file set (1st log file at start + all its rotated files)n

log_method