Migration to CHARON-VAX for Linux
Table of Contents
Introduction
This section describes how to migrate your VAX system to CHARON-VAX. We will use a sample MicroVAX 3600 system to demonstrate the migration procedure. The process is similar for all CHARON-VAX models.
If the CHARON-VAX based virtual system needs to be created from scratch, refer to the appendix "Configuring devices on the Qbus of a VAX or CHARON-VAX" describing how to find proper Qbus addresses and Vectors for each virtual device.
Collecting information about the source VAX system
The first step is to determine the exact configuration of your VAX hardware in order to create the CHARON-VAX configuration file.
Turn on your source VAX system. At the ">>>" prompt, issue the "show qbus" and "show device" commands:
|
|
The source VAX configuration in this example is:
Controller | Address | Devices on controller |
|---|---|---|
RQDX3 | 772150 | -DUA0 (RZ23) |
RQDX3 | 760334 | -DUB2 (RZ25) |
TQK50 | 774500 | -MUA0 (TK50) |
TQK50 | 760444 | -MUB3 (TK50) |
DHQ11 | 760520 |
|
DHQ11 | 760500 |
|
DESQA | 774440 | -XQA0 |
© Stromasys, 1999-2025 - All the information is provided on the best effort basis, and might be changed anytime without notice. Information provided does not mean Stromasys commitment to any features described.
Need fast, reliable migration? We have done it countless times. Talk to an expert