Introduction

This section describes how to migrate your Alpha system to Charon-AXP. We will use a sample AlphaServer ES40 system running OpenVMS to demonstrate the migration procedure. This chapter also contains some instructions for Tru64 UNIX, but it mainly concentrates on how to migrate OpenVMS hosts. The process is similar for all Charon-AXP models.

Collecting information about the source Alpha system

The first step is to determine the exact configuration of your Alpha hardware in order to create the Charon-AXP configuration file that will accurately mimic the hardware.

Turn on your source Alpha system. At the ">>>" prompt, issue a "show device" command:

>>>show device

sys0.0.0.0.0    SYS0     System ROOT Device
ewa0.0.0.1.1    EWA0     F8-D1-11-00-67-E6
pka0.0.0.2.1    PKA0     Q-Logic/ISP PCI SCSI HBA
pga0.0.0.3.1    PGA0     WWN 1000-0000-0248-C550
pqa0.0.0.15.0   PQA0     ALi 1553C Integrated IDE Controller
pqb0.0.1.15.0   PQB0     ALi 1553C Integrated IDE Controller
dqa0.0.0.15.0   DQA0     TSSTcorpCDDVDW SH-222BB
dka0.0.0.2.1    DKA0     DEC RZ28 (C)DEC
dka100.1.0.2.1  DKA100   DEC RZ22 (C)DEC
dka200.2.0.2.1  DKA200   DEC RZ23 (C)DEC
mka600.6.0.2.1  MKA600   Virtual SCSI Tape

>>>

 

To get more detailed information, boot OpenVMS and issue a "show device /full" command:

$ show device /full

Disk PFCAXP$DKA0:, device type RZ28, is online, mounted, file-oriented device,
shareable, available to cluster, error logging is enabled.
...

Disk PFCAXP$DKA100:, device type RZ22, is online, file-oriented device,
shareable, available to cluster, error logging is enabled.
...

Disk PFCAXP$DKA200:, device type RZ23, is online, file-oriented device,
shareable, available to cluster, error logging is enabled.
...

Disk PFCAXP$DQA0:, device type TSSTcorpCDDVDW SH-222BB, is online, file-oriented
device, shareable, available to cluster, error logging is enabled.
...

Disk $1$DGA0: (PFCAXP), device type RZ24, is online, file-oriented device,
shareable, available to cluster, error logging is enabled.
...

Magtape PFCAXP$MKA600:, device type Virtual SCSI Tape, is online, file-oriented
device, available to cluster, error logging is enabled, device supports
fastskip (per_io).
...

Terminal OPA0:, device type VT102, is online, record-oriented device, carriage
control.
...

Device EWA0:, device type DE500, is online, network device, device is a template
only.
...

Device FGA0:, device type KGPSA Fibre Channel, is online, shareable, error
logging is enabled.
...

Device PGA0:, device type SCSI FCP, is online, error logging is enabled.

...

Device PKA0:, device type Qlogic ISP1020 SCSI port, is online, error logging is
enabled.
...

Device $1$GGA32767:, device type Generic SCSI device, is online, shareable.

$

In case of Tru64 UNIX V5 running on the host system it is recommended to use the following commands to get information on the host configuration:

Please reference to the Tru64 UNIX User's Guide for more details.