Setting up a Charon-SSP/4M OCI Instance
This chapter describes how to set up a basic Charon-SSP/4M for OCI instance.
Contents
Prerequisites
General Prerequisites
To access and use Charon-SSP/4M for OCI, you need an Oracle Cloud account.
Licensing
Charon-SSP/4M for OCI requires a license to run emulated SPARC systems. Such licenses can be software or network-enabled hardware licenses.
Please contact your Stromasys representative or your Stromasys VAR for information about the available licensing options. For contact information see About this Guide.
The user is responsible for any Solaris licensing obligations and has to provide the appropriate licenses.
OCI Shape Prerequisites (Hardware Prerequisites)
By selecting a shape in OCI, you select the virtual hardware that will be used for Charon-SSP. Therefore, the selection of an instance type determines the hardware characteristics of the Charon-SSP virtual host hardware (e.g., how many CPU cores and how much memory your virtual Charon host system will have).
Minimum requirements for Charon-SSP:
- Minimum number of host system CPU cores:
- At least one CPU core for the host operating system.
- For each emulated SPARC system:
- One CPU core for each emulated CPU of the instance.
- At least one additional CPU core for I/O. If server JIT optimization is used, add an additional I/O CPU for improved translation speed.
- Minimum memory requirements:
- At least 2GB of RAM for the host operating system.
- For each emulated SPARC system:
- The configured memory of the instance.
- 2GB of RAM (6GB of RAM if server JIT is used) to allow for DIT optimization, emulator requirements, run-time buffers, SMP and graphics emulation.
- One or more network interfaces, depending on customer requirements.
- Charon-SSP/4U+ and Charon-SSP/4V+ must run on hardware supporting VT-x (not applicable to Charon-SSP/4M).
Please note that the sizing guidelines above—in particular regarding number of host CPU cores and host memory—show the minimum requirements. Every use case has to be reviewed and the actual host sizing has to be adapted as necessary. For example, the number of I/O CPUs may have to be increased if the guest applications produce a high I/O load. Also take into consideration that a system with many emulated CPUs in general is also able to create a higher I/O load and thus the number of I/O CPUs may have to be raised.
OCI New Instance Launch
This section only shows a very basic example. Please refer to the Oracle Cloud documentation for more detailed information.
To start the creation of a new cloud instance using Charon-SSP/4M for OCI, perform the following steps:
Step 1: log in to your Oracle Cloud environment.
Step 2: go to the instance list in the compute section and select to create an instance.
This opens the Create Compute Instance window.
Step 3: on the first part of Create Compute Instance window, name your instance and select the Charon-SSP image for it.
To select the correct image, select Change Image Source. This will allow you to browse the different available categories for the Charon-SSP/4M image.
The image below shows an example:
Selecting the image and confirming your selection will take you back to the Create Compute Instance window.
Step 4: on the middle part of the Create Compute Instance window, select the appropriate shape (i.e., the virtual Charon host hardware) and the subnet membership.
To select an appropriate shape conforming to the hardware requirements of the emulated SPARC system, click on Change Shape.
This will open a window where you can select the correct system type.
Confirming you selection will take you back to the Create Compute Instance window.
Step 5: on the bottom of the Create Compute Instance window configure your boot device as required and upload the public SSH key of the key-pair you will use to access your instance.
Click on Create to create your instance.
Step 6: verify your instance is running.
Your instance should now be visible in the list of compute instances.
© Stromasys, 1999-2024 - All the information is provided on the best effort basis, and might be changed anytime without notice. Information provided does not mean Stromasys commitment to any features described.