General Description

CHARON-AXP offers two-port serial console on all supported AXP models.

Example for OPA0 console ("COM1" port):

set COM1 alias=OPA0

When using the TTA0 console ("COM2" port):

set COM2 alias=TTA0

Refer to Mapping Serial line controllers to system resources for details of mapping.

General parameters

CHARON-AXP console lines COM1 and COM2 have the following parameters:

(info) All the values in the following tables are case insensitive.

alias

Parameteralias
TypeIdentifier
Value

This parameter is used to set an useful name for COM1 or COM2 ports.  It can be any name, for example "Console1", but usually it is "OPA0" for COM1 and "TTA0" for COM2.

This name is logged in CHARON log file, it can also be used for parametrization in CHARON configuration file along with "COM1" and "COM2" identifiers. 

If the "alias" parameter is not specified CHARON log file will miss the name for the given console, for example " : Connected. Remote 127.0.0.1:63516" will be displayed instead of "OPA0 : Connected. Remote 127.0.0.1:63516". So it is always recommended to specify the "alias" parameter.

Example:

set COM2 alias=TTA0

communication

Parametercommunication
Type

Text string

Value
  • "ascii" - for connection to terminals  (default)

  • "binary" - for binary (packet) protocols, which are used mainly for communicating with PLCs

baud

Parameterbaud
TypeNumeric
Value

Forces the baud rate of the corresponding TTY port to a specified value.The variety of supported values depends on the underlying physical communication resource (TTY port). The most widely used values are: 300, 1200, 9600, 19200, 38400.

Example:

set OPA0 baud=38400

break_on

Parameterbreak_on
TypeText string
Value

Specifies what byte sequences received over the physical serial line will trigger a HALT command.

This parameter works only for the console line.

Specify the following values: "Ctrl-P" , "Break" or "none" ("none" disables triggering a HALT condition).

If your guest operating system is OpenVMS in addition to "none" setting you have to set a specific console parameter "controlp" to "off" in the following way:

>>> set controlp off
>>> power off 

The second line is to preserve the ROM settings.

Example:

set OPA0 break_on="Ctrl-P"

The default value is "Break".

(warning) This parameter can be specified only for COM1 (OPA0) console


stop_on

Parameterstop_on
TypeText string
Value

Specifies what byte sequences received over the physical serial line will trigger a STOP condition. The STOP condition causes CHARON-AXP to exit.

Specify either “F6” or “none” ("none" disables triggering a STOP condition).

Example:

set OPA0 stop_on="F6"

The default value is "none".

Setting "F6" triggers the STOP condition upon receipt of the "<ESC>[17~" sequence. Terminals usually send these sequences by pressing the F6 button

(warning) This parameter can be specified only for COM1 (OPA0) console

log

Parameterlog
TypeText string
Value

A string specifying a file name to store the content of the console sessions or a directory where the log files for each individual session will be stored.

If an existing directory is specified, CHARON-AXP automatically enables creation of individual log files, one for each session using the same scheme as used for the generation of the rotating log files. If the "log" parameter is omitted, CHARON-AXP does not create a console log.

Examples:

set OPA0 log="log.txt"
set OPA0 log="/Charon/Logs"

Only existing directory can be used as a value of the "log" parameter.


log_file_size

Parameterlog_file_size
TypeText string
Value

If log rotation is enabled, the log_file_size parameter determines the log file size threshold at which the log is automatically rotated.

  • "unlimited" or "0" (default) - the feature is disabled
  • "default" - default size is used (4Mb)
  • <size>[KMG] - size of the current log file in bytes with additional multipliers:
    • K - Kilobyte - multiply by 1024

    • M - Megabyte - multiply by 1024*1024

    • G - Gigabyte - multiply by 1024*1024*1024

Examples:

set OPA0 log_file_size="default"

set OPA0 log_file_size=10M

(warning) Minimum log file size is 64K, maximum is 1G. Setting size less then 64K effectively makes the log file unlimited.

log_flush_period

Parameterlog_flush_period
TypeNumeric
Value
  • <period-in-seconds>

Defines a period of flushing log to disk.

Default period is 60 seconds (it means that every minute log file is flushed to disk)

Example:

set OPA0 log_flush_period=30

port

Parameterport
TypeNumeric
Value

The TCP/IP port number for the virtual serial line. A virtual serial line always listens on this port for incoming connection requests.

If multiple virtualized machines are running on a server, ensure the port number is unique across the platform.

application

Parameterapplication
TypeText string
Value

A command line for calling some host application for communication to Charon on a given COM line.

Typically this parameter is used for mapping COM1 or COM2 or some "xterm" terminal emulator

Example:

set OPA0 application = "xterm -title OPA0 -e telnet 127.0.0.1 10003"

Notes on "port" and "application" parameters

Use the combination of "port" and "application" parameters as follows to connect a 3rd party terminal emulator or similar program.

set COM1 alias=OPA0 port=10003 application="xterm -title OPA0 -e chterm -h 127.0.0.1:10003"


In this example CHARON-AXP OPA0 console connects to port 10003 of localhost ("127.0.0.1") and at the same time it starts "xterm" with parameters "-title OPA0 -e chterm -h 127.0.0.1:10003", instructs it to connect to the port 10003 of the host with TCP/IP address "127.0.0.1" (localhost)


Mapping Serial line controllers to system resources

line

Parameterline
TypeText string
Value

A defined TTY port on host system:

SyntaxDescription
"/dev/tty<N>"Virtual serial lines
"/dev/ttyS<N>"Onboard serial lines
"/dev/ttyUSB<N>"Modem or USB serial lines adapters
"/dev/tty<XXX>"Proprietary (depending on a driver) devices such as DIGI or MOXA cards

A specific account for running CHARON ("charon") does not allow usage of physical consoles "/dev/tty<N>" as CHARON consoles. If you plan to map CHARON console to "/dev/tty<N>" use only "root" account for CHARON running.

"ttyY" notation specifics

Note that the "ttyY" notation can have different forms depending on the nature of the device used:

MappingTypeCommentary

"/dev/tty<N>"

where N is from 0 to 11

Linux virtual tty

Those tty devices must be free from the Linux "getty/mgetty" and similar programs (specified in "/etc/inittab")

Example:

"/dev/tty1"


"/dev/ttyS<N>"

where N is a number

Onboard serial lines

Example:

"/dev/ttyS1"

"/dev/tty<XXX>"

where XXX is a complex letter/number notation

Proprietary (depending on a driver) devices 

Example for a first port of a MOXA card:

"/dev/ttyR01"

Example for a first port of a DIGI card:

"/dev/ttyaa"

"/dev/ttyUSB<N>"

where N is a number

Modem or USB serial lines adapters

Example:

"/dev/ttyUSB1"

  • No labels