Problem
CHARON-AXP/SMA reports the following messages:
2015-08-27 06:00:03:251: CNA001: WARNING: failed to lock memory base=000000002D070000 size=0x3800000 2015-08-27 06:00:03:251: CNA001: reason: Insufficient quota to complete the requested service. [1453] 2015-08-27 06:00:03:283: CNA001: starting the emulator |
Solution
This bug is harmless: SMA tried to lock allocated memory to avoid Windows memory swapping for guaranteed performance in memory access, it may affect performance when swapping happens but doesn't affect emulator behavior.
Bug is solved starting with CHARON-AXP/SMA version 2.2.40. Upgrade is then required
Related articles
Readers/approval
- Your approval is needed for this document