Anchor | ||||
---|---|---|---|---|
|
Include Page | ||||
---|---|---|---|---|
|
Problem
The emulator fails to start when executed from the Charon CHARON Launcher utility on Windows.
...
Highlight | ||
---|---|---|
| ||
The configured node failed to initialize due to configuration errors. |
Example:
Solution
CHARON-VAX and -AXP version 4.3 for Windows and above are using Sentinel HASP protection mechanism, hence they cannot be started through RDP (Remote Desktop Protocol) connection.
...
- either to disconnect and connect directly from the server console
or to use remote management tools: HP ILO, VMware console, Teamviewer, and similar
- or to install the virtualized machine as a service (refer to Charon-AXP or Charon-VAX users guides)
Related articles
Filter by label (Content by label) | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
...