The example below shows the serial console configuration of a Charon-SSP/4U and a Charon-SSP/4V system.
Charon-SSP/4U |
Charon-SSP/4V |
Only one connection to the console is possible at one time. If the Charon Manager is connected via the integrated SSH tunnel and you try to open a second connection to the console (e.g., via a remote terminal emulation program), Charon Manager will terminate the second connection and re-establish the built-in console connection. If the Charon Manager is not running or not connected via the integrated SSH tunnel, a console connection can be established via a remote terminal program and the built-in console tab will be disconnected.
If a second connection via Charon Manager is made to the same system, the current Charon-Manager connection is terminated.
Div | ||
---|---|---|
| ||
Console Access via the Emulated Graphics Device (Charon-SSP/4M/4U(+) only)
...
to configure the graphics device correctly in the Solaris guest system.
Div | ||
---|---|---|
| ||
After starting the emulated system, the graphics devices opens:
OPB console | Desktop after booting |
Please note:
The graphical performance depends on many parameters, for example, the performance of the host system, the emulated system, and the network.
One important requirement is that the round-trip time of the network connection between display device and emulated Solaris system running on the AWS instance should be less or equal to 20ms.
For every use case, a test is required to evaluate the suitability for the specific customer environment.
...