CHARON-AXP/SMA reports the following messagemessages:
2015-08-27 |
...
06:00:03:251: |
...
CNA001: |
...
WARNING: |
...
failed |
...
to |
...
lock |
...
memory |
...
base=000000002D070000 |
...
size=0x3800000 |
...
2015-08-27 |
...
06:00:03:251: |
...
CNA001: |
...
reason: |
...
Insufficient |
...
quota |
...
to |
...
complete |
...
the |
...
requested |
...
service. |
...
[1453] |
...
2015-08-27 |
...
06:00:03:283: |
...
CNA001: |
...
starting |
...
the |
...
emulator |
"The problem reported below from customer, in fact was a bug in SMA. It is fixed in latest version (2.2.40) but not in the version that customer uses.
...
Solution
This bug is harmless: SMA tried to lock allocated memory to avoid Windows memory swapping for guaranteed performance in memory access, it may affect performance when swapping happens (most of cases won't, I believe) but doesn't affect emulator behavior.
We could simple tell them it's not harmful."
Solution
Bug is solved starting with CHARON-AXP/SMA version 2.2.40. Upgrade is then required
Related articles
Filter by label (Content by label) | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
...