Introduction
It is possible to run one or several instances of CHARON-VAX / CHARON-PDP at the same time if your license allows it.
In case of multiple instances, please use only absolute paths and unique names to all the files referenced in the configuration file of each CHARON-VAX / CHARON-PDP instance (log, toy clock, nvram files and all the other data such as disk images - all these objects to be discussed later in this document). Also, hardware devices (e.g., CD-ROM) may be used by only one instance at a time (not shared).
Example:
|
Please refer to the next chapters for more details concerning CHARON-VAX / CHARON-PDP configuration details.
Running from a Desktop shortcut
The CHARON installation procedure creates shortcuts on the desktop for so-called "default" VAX/PDP11 model and shortcuts under "Start" menu for all VAX/PDP11 models included during installation.
Desktop shortcut:
"Start" menu shortcuts:
To run a certain CHARON-VAX / CHARON-PDP model, double click the target model's desktop shortcut (or click on "Start" menu shortcut).
By default the CHARON sample configuration files do not contain any specification of disks and network; you need to update a copy of the sample configuration file to specify your specific disk and network configuration.
Depending on settings, Windows may display a Firewall warning dialog asking to confirm CHARON access to different networks.
Check the desired options and press "Allow access" button.
The CHARON icon will appear in the system tray menu:
Next, the VAX/PDP11 emulated console will appear:
If the CHARON icon in the system tray menu disappears, it means a critical error happened at run-time. In this case you have to analyze the CHARON log file, by default stored beside CHARON executables. The default location for log files is "C:\Program Files (x86)\CHARON\Build_XXX\x86" (x64) or "C:\Program Files\CHARON\Build_XXX\x86" (x86). The name of the log file depends on the model of emulated VAX/PDP11 and the date and time, for example "MicroVAX_3100_Model_98-2015-08-05-14-40-51-000000000.log"
The easiest way to find the needed log file is to sort all the files in the CHARON executables directory by date of modification.
Generally it is not recommended to use template (sample) configuration files (used in shortcuts) for your configuration since those files are part of the installation and may be deleted by the CHARON installation procedure on modifications or re-installation. It is a good practice to copy the required configuration template from "C:\Program Files (x86)\CHARON\Build_XXX\x86" (x64) or "C:\Program Files\CHARON\Build_XXX\x86" (x86) directory to some local file and build the configuration from there.
Once the sample configuration files are copied, the CHARON default shortcut (created by the installation procedure) can be changed to use your target configuration file:
- Right click on CHARON shortcut for target VAX/PDP11 model
- Choose "Properties"
- In the "Target" edit box, change the default template configuration file path and name to the local one. For example "C:\My configurations\my_mv3k6.cfg"
- Press "Apply" button
The next step is to install or copy a system disk for CHARON operation. This can be either installation of a new VMS, RSX11, RT11, etc. system using a distributive provided by HP or a transfer of data from an existing VAX/PDP11 system. These possibilities will be discussed in detail in the next chapters.
To exit from CHARON-VAX / CHARON-PDP emulator use the following methods:
- Configuration with no changes to the template configuration file
Right click on CHARON icon in the system tray menu, choose "Stop & Exit":
.
Configuration file updated to enable "F6" button in configuration file to trigger exit from CHARON:
#----------------------------------------------------------------------------
#
# Uncomment to allow 'F6' to terminate the running emulator.
#
#----------------------------------------------------------------------------
set OPA0 stop_on = F6
- To exit, press "F6" in the console window
- Use CHARON icon tray menu as shown above
Before stopping the CHARON-VAX / CHARON-PDP service, shutdown the operating system running in CHARON-VAX / CHARON-PDP.
Running from the Launcher utility
Running from the "CHARON Launcher" utility is very convenient during the debugging of your CHARON configuration. The utility shows CHARON log updates in real time. If RDP is used to connect to the CHARON host, the CHARON may not see the license; start CHARON as a Service instead. From the Launcher, CHARON runs as a User process which will terminate if the User logs off. The Service is a System process and will continue to run until stopped.
Start the Launcher:
In the Launcher main interface, click the "Browse" button to select the desired CHARON configuration file:
Select the desired configuration file:
The Launcher will display the CHARON model specified in the selected configuration file:
Now it is possible to run CHARON. Press "Run selected configuration" button.
Depending on system settings, Windows may display a Firewall warning dialog asking to confirm CHARON access to different networks.
Check the desired options and press "Allow access" button.
Next, the CHARON icon will appear in the system tray menu:
Right after that the VAX/PDP11 emulated console will appear (in the default configuration. Some configurations may not assume console startup):
The Launcher will display CHARON log file:
Log messages have the following colors:
- lightyellow means information
- cyan means warning
- red means error
It is possible to scroll the log file to analyze possible problems.
To exit from CHARON-VAX / CHARON-PDP emulator use the following methods:
- Configuration with no changes to the template configuration file
Right click on CHARON icon in the system tray menu, choose "Stop & Exit":
Using this menu, it is also possible to halt the virtual VAX/PDP11, reset it or show its console if it has been closed
Configuration file updated to enable "F6" button in configuration file to trigger exit from CHARON:
#----------------------------------------------------------------------------
#
# Uncomment to allow 'F6' to terminate the running emulator.
#
#----------------------------------------------------------------------------
set OPA0 stop_on = F6
- To exit, press "F6" in the console window
- Use CHARON icon tray menu as shown above
Before stopping the CHARON-VAX / CHARON-PDP service, shutdown the operating system running in CHARON-VAX / CHARON-PDP.
After CHARON exit press "Exit" button to quit from the Launcher.
Running as system service
It is possible to run CHARON-VAX / CHARON-PDP as a Windows service.
Follow the description below to establish and run CHARON-VAX / CHARON-PDP as Windows service
Installation and start of CHARON-VAX / CHARON-PDP service
Open the "CHARON Launcher" utility from "Start" menu:
In the "CHARON Launcher" main interface press "Browse" button to select CHARON configuration to be used by CHARON running as Windows service:
Choose the desired CHARON configuration file to be installed as service:
The Launcher will display the specific CHARON model name specified in the configuration file and enable management buttons:
Press "Edit CFG file" button and edit (with standard "Notepad" program) the chosen configuration file:
Use only absolute paths to log, toy clock, nvram files and all the other data such as disk images etc. The names of the references files must be unique too, for example
...
set session log="C:\My Services\my_mv3k6.log"
set toy container="C:\My Services\my_mv3k6.dat"
load RQDX3/RQDX3 DUA
set DUA container[0]="C:\My Services\mv3k6_daemon_boot_disk.vdisk"
...
- Make sure the same physical devices are not used by other CHARON-VAX / CHARON-PDP services
Save configuration file with "Notepad" save feature, exit from it.
Run the configuration to make sure that it is ready to be installed as Windows service; stop CHARON (see above how to do that).
Press "Install / Update service" button in the Launcher:
A special dialog for adding new CHARON service will appear:
Enter a new service name (in the example above it is "charon-3100") and press "Install" button. If the service has been installed correctly, a configration dialog box will appear:
Press "Ok" button, then exit from "Launcher" by pressing "Exit" button.
CHARON service is installed, now let's configure it. Start the "CHARON Service Manager" utility:
It is also possible to start the "CHARON Service Manager" utility from the system tray menu:
In the main window of the utility, select the target CHARON service ("charon-3100" in our example) and press the "Service" button (labeled with yellow on the screenshot below):
The "Service Management dialog" will appear:
The "Service Management dialog" shows the current status of the selected CHARON service and permits changes to its start up type and to start and stop it. The example screenshot above shows that the service "charon-3100" startup type is "MANUAL" (can be started / stopped only manually) and in the "Stopped" state - these are the default values.
Press the "Start" button to start the service:
CHARON will start and the Service status will be "Started". To stop the service, press the "Stop" button.
It is possible, and often desirable, to configure the selected CHARON service to start when host operating system starts. To enable this capability, select "AUTOMATIC" in the "Startup type" drop-down box and press the "Apply" button:
Note that a certain delay may occur before the Sentinel Run-time process finds the network license on CHARON-VAX/PDP11 host system startup. If the CHARON-VAX/PDP11 service is starting automatically on the host system, it may report a "License not found" error and exit.
This problem can be avoided by specifying "license_key_lookup_retry" parameter in the configuration file:
set session license_key_lookup_retry = "N [, T]" |
where:
- N - Number of retries looking for license key (or keys)
- T - Time between retries in seconds. If not specified 60 seconds is used
Example:
set session license_key_lookup_retry = 5 |
In this example, if the license key is not found during the initial scan, CHARON-VAX/PDP11 will scan 5 more times, waiting 60 seconds between them before it stops.
See the "General Settings" section for more details.
Management of CHARON-VAX / CHARON-PDP service
To see the execution log of a CHARON service, select the service ("charon-3100" in the example below) and the current log messages will be displayed in the right panel of the utility interface. You may need to scroll up to see startup/previous messages:
To control execution of CHARON services, open the "CHARON Service Manager" utility from the "Start" menu or use the system tray shortcut to manage the services w/o opening the main window of the utility:
Press the right button of the mouse to see a list of the installed CHARON services ("charon-3100" in our example):
Select the Service to see the list of the available operations:
Explanation:
Menu Item | Function |
---|---|
Start | Start CHARON service |
Show Console | Show CHARON service console if it has been closed or not active on the automatic service startup |
Halt | Halt VAX/PDP11 emulator associated with the selected CHARON service |
Reset | Reset the virtual VAX/PDP11 associated with the selected CHARON service |
Stop | Stop CHARON service |
Show Log | Show execution log of the selected CHARON service |
Choose the desired action and click on it.
Stopping CHARON-VAX / CHARON-PDP service
Open up "CHARON Service Manager" utility from the "Start" menu:
or from the system tray menu:
In the main window of the utility, select the target CHARON service ("charon-3100" in our example) and press the "Service" button (labeled with yellow on the screenshot below):
Press the "Stop" button in the resulting dialog box:
The CHARON Service can be Stopped using the shortcut on the Windows Task Bar.
Open up the "CHARON Service Manager" system tray menu, select the service you are going to stop and click on the "Stop" command:
Please note: before stopping the CHARON-VAX/PDP11 service, shutdown the operating system running in CHARON-VAX/PDP11.
Modification of CHARON-VAX / CHARON-PDP service
Note that it is not enough just to modify the CHARON configuration file associated with a given CHARON service to apply the changes. You must also update the CHARON service with the "Launcher" utility.
Update the CHARON-VAX / CHARON-PDP configuration file for the CHARON service.
Start up the "CHARON Launcher" utility:
In the "CHARON Launcher" utility, select the modified configuration file and run it as described above.
Make sure that the configuration starts without errors, then stop CHARON-VAX / CHARON-PDP as described above.
If errors appear, stop CHARON-VAX or CHARON-PDP, update its configuration file, start it again and make sure that the updated configuration works Ok this time, then stop CHARON-VAX / CHARON-PDP.
Once CHARON-VAX / CHARON-PDP has been completely stopped, press the "Install / Update service" button:
The install / update dialog will appear:
Press "Update existing service" button:
Select the service to update with the "Installed services list" drop-down box and press "Update" to apply.
Please note that before updating CHARON-VAX / CHARON-PDP service, one must stop it.
Removing CHARON-VAX / CHARON-PDP service
To remove the CHARON-VAX / CHARON-PDP service, open the "CHARON Service Manager" utility from the "Start" menu:
or from the system tray menu:
Please note: before stopping the CHARON-VAX / CHARON-PDP service, shutdown the operating system running in CHARON-VAX / CHARON-PDP.
In the main window of the utility, select the CHARON service to remove ("charon-3100" in our example) and press the button with an exclamation sign on it:
Confirm removal of the selected CHARON service by pressing the "Remove" button:
Please refer to the next chapters for more details concerning CHARON-VAX / CHARON-PDP configuration details