Serial lines

Serial lines

Table of Contents

General Description

Before build 204-14

Configuration of the CHARON-VAX / CHARON-PDP serial lines is performed in 3 steps:

  1. Loading the virtual serial lines' controller, for example:

    In this example, an instance of a  "DHV11" serial line controller is loaded and named "TXA".

    Note that the VAX/PDP11 console adapters ("UART", "QUART") do not need to be loaded; they are preloaded.

  2. Mapping an object type to host resources. For example for the virtual serial lines (see below):

    In this example the object "virtual_serial_line" is loaded, named "TTA1", mapped to the "putty" terminal emulator and connected to this CHARON instance using the port 10003 (this setting is also specified via the partameter "-P". "CHTERM-VT100" parameter stands for the Putty terminal emulator specific settings. "-title" parameter is used for naming the terminal emulator window.

  3. Connect the loaded virtual line controller and the mapped object:

    In this example, the 6th line of the DHV11 controller, "TXA", loaded in step 1, is connected to the mapping object, "TTA1", loaded in step 2.

This syntax is still supported after build 204-14 but using it will not provide the new features provided by this build.

Starting with build 204-14

Configuration of the CHARON-VAX / CHARON-PDP serial lines is performed as detailed below:

Example for MicroVAX II, 3600, 3900, VAX 4000-700/705:

set UART alias=OPA0
set OPA0 port=10003 application="putty -load CHTERM-VT100 -title OPA0@myvax -P 10003"

 The first line above is optional as Charon-VAX/PDP presets UART's alias to OPA0

Example for MicroVAX 3100-96/98, VAX 4000-106/108, and VAXstation 4000-90:

set QUART alias[3] = OPA0
set OPA0 port=10003 application="putty -load CHTERM-VT100 -title OPA0@myvax -P 10003"

 The first line above is optional as Charon-VAX/PDP presets UART's alias to OPA0

 

Refer to Mapping Serial line controllers to system resources for details of mapping and examples provided in the configuration file templates located in the Charon installation folder.
Please note using the old method with "load virtual_serial_line OPA0" will invalidate some features detailed further.

Console

CHARON-VAX / CHARON-PDP offers a one- or four-port serial console, depending on the specified VAX/PDP11 model. The one port serial line controller is identified in CHARON-VAX / CHARON-PDP with the name UART. The four port serial lines controller is identified in CHARON-VAX with the name QUART.

UART is used in Qbus systems only (e.g. the MicroVAX/VAXserver 3600/3900, PDP11/93 and PDP11/94).

QUART is used in SCSI (e.g. MicroVAX 3100 model 96/98, VAXstation 4000 model 90) and SCSI/Qbus systems (e.g. VAX4000 model 106/108). The last QUART line (line[3]) is the console port (known in VAX/VMS as OPA0).

CHARON-VAX / CHARON-PDP console ports can be configured to connect to an external terminal via the host system COM port or can be connected via TCP/IP.

alias

This applies to new syntax only, not if "load ..." is used.

Parameter

alias

Type

Identifier

Value

The main purpose of this parameter is migration from old CHARON systems (which do not have the described implementation of consoles) to the current design, since it allows retaining the original name used for parametrization, since the rest of the parameters stay the same in both implementations. 

Exampleset UART alias=OPA0

 This parameter is optional as Charon-VAX/PDP presets UART's alias to OPA0

rts

Parameter

rts[<line>]

Type

Text string

Value

  1. "On" - assert the RTS (Request To Send) signal

  2. "Off" - clear the RTS signal (default)

  3. "DTR" - assert the RTS signal as soon as the DTR signal is asserted ( Applicable only for QUART )

dsr

Parameter

dsr[<line>]

Type

Text string

Value

  1. "On" - always reports DSR signal assertion

  2. "Off" - always reports DSR signal deassertion

  3. "DSR" - use the DSR signal of the physical serial line (if configured)

  4. "CD", "DCD", "RLSD" - use the CD (carrier detect) signal of the physical serial line (if configured)

This parameter is applicable only for line "2" of QUART. UART has no such parameter

communication

Parameter

communication[<line>]

Type

Text string

Value

  1. "ASCII" - for connection to terminals  (default)

  2. "BINARY" - for serial lines carrying binary (packet) protocols, which are used mainly for communicating with PLCs

line

Parameter

line[<line>]

Type

Identifier

Value

This parameter is used to connect a particular serial line interface to the controller. See below for details.

Note that the "line" parameter in the table above is applicable only in the case of QUART.

All the values in this table are case insensitive.

Example:

set QUART rts[2]="DTR"
set QUART dsr[2]="On"
set QUART communication[2]="binary"

    

Line 2 of the QUART is the only one which can be used for connecting modems. Therefore, the "DSR" parameter for that line (i.e. "dsr[2]") is internally set to the appropriate value ("CD") but can be changed from the configuration file. Values for the "rts" and "dsr" parameters for the lines other than 2 are not visible for any applications running on CHARON-VAX / CHARON-PDP.

Serial line controllers

Asynchronous serial line multiplexers are capable of serving up to 8 asynchronous serial lines (the DHW42-BA supports up to 16 lines).

The following asynchronous serial line multiplexers are supported:

 

VAX model

Asynchronous serial line emulation

VAX model

Asynchronous serial line emulation

PDP-11/93,
PDP-11/94,
MicroVAX II,
MicroVAX 3600,
MicroVAX 3900,
VAXserver 3600,
VAXserver 3900  (QBUS systems)

CXA16, CXB16, CXY08, DHQ11, DHV11, DZV11, DZQ11, DL11, DLV11, DZ11

MicroVAX 3100 - 96,
MicroVAX 3100 - 98 (SCSI systems)

DHW42-AA, DHW42-BA, DHW42-CA

VAX4000 - 106,
VAX4000 – 108,
VAX4000 – 700,
VAX4000 – 705 (QBUS/SCSI systems)

CXA16, CXB16, CXY08, DHQ11, DHV11, DZV11, DZQ11, DLV11, DHW42-AA, DHW42-BA, DHW42-CA

VAX6310, VAXstation 4090

N/A

The following names are used for the multiplexers:

 

Device name

Module name

Device name

Module name

DHV11

DHV11

DHQ11

DHV11

CXY08

DHV11

CXA16

DHV11

CXB16

DHV11

DHW42AA

DHV11

DHW42BA

DHV11

DHW42CA

DHV11

DZV11, DZ11

DZ11

DZQ11

DZ11

DL11, DLV11

DL11

The following example loads an instance of an asynchronous serial line multiplexer:

load DHQ11/DHV11 TXA

Only one instance of DHW42 can be loaded. There is no restriction on the number of the other multiplexers.

The multiplexers offer the following configuration parameters, specified with the "set" command:

address

Parameter

address

Type

Numeric

Value

Specifies CSR address. The address must be a valid QBUS 22-bit wide address in I/O space.

Default values are 017760440 for the DHV11-family controllers and 017760100 for the DZV11/DZQ11 family controllers, which are the factory settings for asynchronous serial line multiplexers.

This parameter is not applicable to DHW42-xx serial line controllers.

vector

Parameter

vector

Type

Numeric

Value

Specifies the interrupt vector.

The default value is 0300, which is the factory setting for asynchronous serial line multiplexers.

This parameter is not applicable to DHW42-xx serial line controllers.

line

Parameter

line[N]

N=0…3(7,15)

Type

Identifier

Value

Specifies the name of the serial line interface object in the configuration to which the N-th line of the multiplexer is connected. See below for details.

communication

Parameter

communication[N]

N=0…4(7,15)

Type

Text String

Value

  1. "ASCII" - for connection to terminals  (default)

  2. "BINARY" - for serial lines carrying binary (packet) protocols, which are used mainly for communicating with PLCs

rts

Parameter

rts[N]

N=0…3(7,15)

Type

Text String

Value

Controls the RTS signal of the Nth line of the multiplexer. 

  1. "On" - assert the RTS (Request To Send) signal

  2. "Off" - clear the RTS signal (default)

  3. "DTR" - assert the RTS signal as soon as DTR signal is asserted

When left blank (initial state), the level of the RTS signal is as requested by the VAX/PDP11 software.

dsr

Parameter

dsr[N]

N=0…3(7,15)

Type

Text String

Value

  1. "On" - always reports the DSR signal assertion

  2. "Off" - always reports the DSR signal deassertion

  3. "DSR" - use the DSR signal of the physical serial line (if configured)

  4. "CD", "DCD", "RLSD" - use the CD (carrier detect) signal of the physical serial line (if configured)

This parameter is applicable only to the DZV11 and DZQ11 serial lines controllers.

tx_q_max_depth

Parameter

tx_q_max_depth[N]

N=0…3(7,15)

Type

Numeric

Value

Specifies the depth of the TX FIFO for the N-th line of the multiplexer. Possible values are 1…1000, initially set to 1, to properly represent the hardware limitation of certain multiplexers. Values greater than 1 improve transmission rate of the corresponding lines, but break correspondence to the original hardware.

This parameter is applicable only to the DHV11 serial lines controllers.

 

Use the "address" and "vector" parameters to load several instances of the Qbus multiplexers. Both "address" and "vector" parameter values must be unique for every instance of a QBUS multiplexer.

Read the VAX/PDP11 hardware documentation and the VM system management documentation to understand how to correctly assign the "address" and "vector" parameters.

 

Example: loading 2 instances of DHV11

load DHV11/DHV11 TXA address=017760440 vector=0300
load DHV11/DHV11 TXB address=017760460 vector=0310

Example: loading DHW42CA

load DHW42CA/DHV11 TXA

Mapping Serial line controllers to system resources

Types of serial line mapping

Type

Function

Type

Function

physical_serial_line

This type of mapping associates a COM port on a host system with an emulated VAX/PDP11 serial line controller virtual "line".

The COM port can be a physical hardware port or a logical COM port.

virtual_serial_line

This type of mapping associates a network connection on the host system with an emulated VAX/PDP11 serial line controller virtual "line"

Example:

load physical_serial_line/chserial OPA0

physical_serial_line

line

Parameter

line

Type

Text string

Description

A defined COM port on a host system in the form of "\\.\COMn"

Example:

set OPA0 line="\\.\COM1"

baud

Parameter

baud

Type

Numeric

Description

Forces the baud rate of the corresponding COM port to be a specified value.

The variety of supported values depends on the underlying physical communication resource (COM port). The most widely used values are: 300, 1200, 9600, 19200, 38400.

Example:

set OPA0 baud=38400

break_on

Parameter

break_on

Type

Text string

Description

Specifies what byte sequences received over the physical serial line will trigger a HALT command.

This parameter works only for the console line (for the one UART line and "line[3]" of QUART).

Specify the following values: "Ctrl-P", "Break" or "none" ("none" disables triggering a HALT condition).

Example:

set OPA0 break_on="Ctrl-P"

The default value is "Break" for line 3 of QUART and "none" for other lines.

stop_on

Parameter

stop_on

Type

Text string

Description

Specifies what byte sequences received over the physical serial line will trigger a STOP condition. The STOP condition causes CHARON-VAX / CHARON-PDP to exit.

This parameter works only for the console line (for the one UART line and "line[3]" of QUART).

Specify the one of the following values: “F6” or “none” ("none" disables triggering a STOP condition).

Example:

set OPA0 stop_on="F6"

The default value is "none".

Setting "F6" triggers the STOP condition upon receipt of the "<ESC>[17~" sequence. Terminals usually send these sequences by pressing the F6 button

log

Parameter

log

Type

Text string

Description

A string specifying a file name to store the content of the console sessions or a directory where the log files for each individual session will be stored.

If an existing directory is specified, CHARON-VAX / CHARON-PDP automatically enables creation of individual log files, one for each session using the same scheme as used for the generation of the rotating log files. If the "log" parameter is omitted, CHARON-VAX / CHARON-PDP does not create a console log.

Example 1:

set OPA0 log="log.txt"

Example 2:

set OPA0 log="C:\Charon\Logs"

Notes:

  1. Specify only an existing directory.

  2. If you want to store the OPA0 log file in the Charon virtual machine home directory (default for virtual machine log file), use: set OPA0 log=".\."

log_file_size

Parameter

log_file_size

Type

Text string



© Stromasys, 1999-2025  - All the information is provided on the best effort basis, and might be changed anytime without notice. Information provided does not mean Stromasys commitment to any features described. 
Need fast, reliable migration? We have done it countless times. Talk to an expert