Comment: add access option description

...

  • TCP raw: configure the console device as a network device (TCP socket) without any protocol enabled.

  • Telnet: configure the console device as a network device (TCP socket) with the telnet protocol enabled.

  • Physical: configure the console device as physical terminal directly attached to the host system. For an AWS instance, this could be a virtual serial line provided by a serial line server (terminal server).

  • Disabled: disable the virtual console device entirely.

Div
classpagebreak


Vconsole Network Configuration

...

(warning) Using a port that is already in use results in the following error messages in the virtual machine log file similar to the following.

Image RemovedImage Added

To access the console of a guest system across the network without, make sure the port configured for the console is permitted by any intermediate firewalls and/or security groups. If using the built-in console function of the Charon Manager in combination with the Charon Manager SSH tunnel, the console port is redirected through this SSH tunnel.

Console:

For Charon-SSP AWS, the value of this parameter is fixed to Built-in. The built-in console is displayed and accessible from the Console tab in the Charon Manager. The console process listens on TCP port 9000 by default.

...

To access the console of a guest system across the network, make sure the port configured for the console is permitted by any intermediate firewalls and/or security groups. If using the built-in console function of the Charon Manager in combination with the Charon Manager SSH tunnel, the console port is redirected through this SSH tunnel.

Console:

(info) Not applicable to Charon-SSP/4V. Please refer to the Vconsole section instead.

...

For Charon-SSP AWS, the value of this parameter is fixed to Built-in. The built-in console is displayed and accessible from the Console tab in the Charon Manager. The console process listens on TCP port 9000 by default.

Access:

Possible values:

Unlimited: Connection to the console is possible via a remote network connection.

Local only: Connection to the console is only possible from the local host.

Log:

When this box is checked, Charon-SSP writes a console log file.

...

To view or change the virtual machine TTYB configuration, select TTYB in the Device column of the left-hand pane of the configuration window. The virtual TTYB serial device can be configured as both a physical or network connected device. The configuration of this device is very similar to TTYA. For further details related to configuring this device, consult the section TTYA Configuration.