Table of Contents | ||||
---|---|---|---|---|
|
Sentinel/Gemalto
...
Tools not Applicable to the VE License Server
Any Sentinel/Gemalto-specific license tools provided with the emulator installation are not applicable to the VE license server configuration.
...
Actions that can Invalidate a VE License
Excerpt | |
---|---|
class | pagebreakFor cloud deployments: if supported by the cloud provider, the VE license server instance can be moved to a different subnet, as long as the original instance can be moved. It is also possible to backup and restore (to the same instance) the license server data. Please note: it is not possible to use such a backup to revert to a previous license version. However, the following actions will invalidate the license:
|
Div | |
|
Starting and Stopping the License Server
...
The licensed service logs information to its log file in /opt/license-server/license_log/license.log and to journalctl.
...
The example below shows the output of such a time-limited license:
Code Block | ||
---|---|---|
| ||
# /opt/license-server/license_viewer <<License Viewer>> Current license: KEYSEC K_FINGER=123db1ec91a1526c40da028b9e68e5abaadc70c62719af0f6ef1f2cfd2c85bba K_LICENSE_ID=License fingerprint: 07792211fc8ce3fdc085 <truncated> Customer name: Stromasys License ID: 01.00000001.002.045 K_TYPE=COUNTDOWN K_EXPIRED=100 K_CUSTOMER=Stromasys/Testing K_PLATFORM=amazon.aws K_R_DATE=1593308906 K_INTERVAL=60 KEYEND PRODSEC P_NAME=Charon-SSP/4U020 Key type: COUNTDOWN Expiration date: 100 hour(s) Platform: amazon.aws Release date: 2021-06-17 13:08:01 Grace period: 120 minutes License check interval: 60 minutes Virtual Hardware: Charon-SSP/4M,Charon-SSP/4U+, Product code: Charon-SSP/4V,Charon-SSP/4V+ P_CODE=test P_MAJV=4 P_MINV=2 P_CPU_NUM=4 P_MAX_MEM=4096MB P_INSTANCE=4 PRODEND PRODSEC P_NAME=Charon-SSP/4M P_CODE=test P_MAJV=4 P_MINV=2 P_CPU_NUM=4 P_MAX_MEM=512MB P_INSTANCE=4 PRODEND |
...
ALL
Expiration date: 2021-12-22 23:55:00
Major Version: 5
Minor Version: 3
Maximum CPU: 64
Maximum virtual memory: 1048576MB
Instances allowed: 3 |
The above sample is a backup license with 100 hours of emulator runtime. The remaining hours can be checked via the web interface.
...
Should the primary license server become unavailable, the emulator tries to connect to the backup license server. If this succeeds, the emulator continues to run without interruption. If no connection to a valid license can be established within 2 hours after the loss of the license has been detected, the emulator will stop. Please note: The grace period is defined on the license.
Please note: If you do not have a valid backup license and the primary license server is unavailable for more than 2 hoursthe grace period, make sure to shut down the guest operating system cleanly before the end of the grace period. Failure to do so may cause data loss or corruption.
If the primary license server becomes available again after the emulator has switched to the backup server, the emulator will automatically switch back to the primary server to avoid unnecessary depletion of the backup license runtime hours in VE license server mode.
Div | ||
---|---|---|
| ||
Log Files
...
License server log file /opt/license-server/license_log/license.log
At every license server start, a new version of the log file is created and the previous file is rotated to license.log.1. Other existing versions are rotated accordingly.
...
Please note: The output shows a 2 hour grace -period. This is applicable to Charon-SSP versions period. The grace period implementation changed several times. In VE versions before version 4.1.21 and later. In earlier versions , the grace - period was 24 hours. This is no longer needed because a backup license server can now be configured (since Charon-SSP version It was shortened to two hours after the introduction of the backup license server feature in 4.1.19). Since version 1.1.12, the grace period is determined by the corresponding license parameter. If a valid license has not become available before the end of the grace period, the emulator will be stopped.
...
License Server version mismatch:
The following message is logged in older versions. Newer versions may have a more descriptive error message.software checks for compatible protocol versions between license server and emulator software. It logs an error if the versions are not compatible.
The following messages may logged in older versions:
Code Block | ||
---|---|---|
| ||
2020-01-16 11:24:38 WARN VE Failed to get data from license server! |
...
Code Block | ||
---|---|---|
| ||
2021-08-10 17:03:42 FATAL VE License server is unavailable! |
Newer versions have a more descriptive error message:
Code Block | ||
---|---|---|
| ||
2021-08-10 17:16:41 ERROR VE License protocol version is invalid. |
Management GUI Web Server Log File
This log file contains errors encountered by the web server providing the management GUI of the VE license server.
Log file location: /opt/license-server/error.log
Sample content:
Code Block | ||
---|---|---|
| ||
$ cat /opt/license-server/error.log
<attempt to start the license server a second time>
[1636549131] [error] [client ] cannot bind to 80: 98 (Address already in use)
[1636549131] [error] [client ] cannot bind to 8084s: 98 (Address already in use)
[1636549131] [error] [client ] Failed to setup server ports
<restart of the license server>
[1636551531] [error] [client 192.168.2.80] SSL syscall error 104
[1636551532] [error] [client 192.168.2.80] SSL syscall error 104
|
Include Page | ||||
---|---|---|---|---|
|