Please note: All Linux and HP-UX sample commands in this section are performed as the root user (prompt = #). This may not be necessary for all commands in all environments depending on the local permission settings. The commands can be executed on the Charon host graphical console or via a non-graphical login (e.g., SSH). However, for accessing the running emulator, the use of PuTTY is strongly recommended because it works best with the emulator environment.
The Charon-PAR/PA9-32 functionality of Charon-PAR emulates historic 32-bit PA-RISC hardware. This section shows a sample installation of a 32-bit guest system.
Emulator Licensing Considerations
Insert excerpt Charon-PAR/PA3 Guest - Basic Configuration and Installation Charon-PAR/PA3 Guest - Basic Configuration and Installation name LicSectionPointer nopanel true
HP-UX ISO Installation Medium
...
The configuration file template must be adapted to the customer environment and the required guest system characteristics. This section describes the minimum number of changes required to configure a Charon-PAR/PA9-32 emulator instance. Please refer to Configuration File Reference for a detailed description of the configuration file options.
...
Step | Description | |
---|---|---|
1 | Create a copy of the configuration file template. | Example:
|
2 | Open the configuration file in a text editor. |
or
|
3 | Configure the system model. | model "720" Configured model must be covered by your license. |
4 | Configure the RAM for the emulated system (in MB). | memory 64 |
5 | Configure the serial console for telnet via PuTTY. | Use the method 2 of the serial line section in the configuration file and make sure the definition of the asp.uart0.device is:
|
6 | Configure disk 1 (system disk). | Change definition of DKA0 to:
|
7 | Add a definition for disk 2 (ISO file) or (if it already exists) modify the definition to point to your ISO installation file for the mini-system (the install disk). |
|
8 | Configure a network card based on a physical host NIC. This NIC is dedicated to the guest operating system and cannot be used for network communication by the host system. To share an interface, a virtual bridge would have to be used (see Ethernet configuration sections in this document). | In the configuration file template, comment out the dummy interface and the tap interface configuration. Then uncomment the interface configuration of the physical interface example. Change the definition of EWA0 to the interface that is assigned to the emulated system (example: eth1) and disable the offload parameters for the interface:
Please note: Depending on the capabilities of the Ethernet device, not all offload parameters maybe be available. This will create a warning message. The variable IFACE is set by the system before executing the initialize command. For cloud environments, please note:
|
9 | Save the configuration file. |
...
Starting the Emulated System and Installing the Guest System
...
Starting with Charon-PAR version 3.0.5 this will, by default, automatically stop the emulator when it detects that the operating system has been halted. See the system.stop_on_halt parameter in the Configuration File Reference. If the emulator is not stopped automatically, continue with step 2 below.
...
For more information about the Charon-PAR console, please refer to Charon-PAR Console. For more information about the Charon-PAR command-line options, please refer to Charon-PAR Command-Line Options.