General description

CHARON-AXP provides the following set of utilities:

to physical tapes.
UtilityDescription
mkdskcmd

Used to create CHARON virtual disk containers of custom or standard types.

This utility also may be used to transfer virtual disks of one type to virtual disks of another type.

hasp_srm_view

Used to display the CHARON license contents, to collect the host system fingerprint and to transfer software licenses from one host to another.

hasp_update

Sentinel standard utility used to retrieve Sentinel protection key information, detach a license from a Sentinel SL key and rehost a license from a Sentinel SL key

ncu

Used to dedicate a host interface to CHARON-AXP, to release it back to the host and to manage CHARON virtual interfaces (TAPs).

mtdUsed to create CHARON tape images from physical tapes and to write tape images back
CHARON Guest Utilities for OpenVMSUsed to manage virtual tapes and CHARON performance.

All these utilities are invoked from Linux console command line.

 Back to Table of Contents

...

Creating disk images

The "mkdskcmd" utility:

  • Creates empty disk images of a given standard disk type or a custom disk size
  • Transfers existing disk images of one type to disk images of another type.

The first step is to obtain the name of the disk that needs to be created:

$ mkdskcmd --list

This command results in a list of all supported disk types.

Choose the desired disk (for example "RZ22"), then use the "mkdskcmd" command  to create the virtual disk image as shown below:

...

A disk container "rz22.vdisk" will be created in the current directory.

Info

A file "rz22.avdisk" will also be created. This file helps CHARON accurately recognize a specific disk image type. It is recommended to put the ".avdisk" file in the same directory as the created disk image.

It is also possible to create custom disk images using "--blcount" (blocks count) and "--blsize" (blocks size) switches.

To get all the available parameters please use the "–help"switch:

...

mkdisk for CHARON utility v. 1.14
Copyright: STROMASYS, 2015

Usage:
mkdskcmd [Options]

Options:
--help - to see help screen
-h - to see help screen

--output <full name> - to specify output file name
-o <full name> - to specify output file name

--disk <disk name> - to specify the disk name from Disk table
-d <disk name> - to specify the disk name from Disk table

--blsize <number> - to specify the block size in bytes (custom disk image)
-z <number> - to specify the block size in bytes (custom disk image)

--blcount <number> - to specify number of the blocks (custom disk image)
-c <number> - to specify number of the blocks (custom disk image)

--avtable <full_name> - to specify AVDISK table file
-a <full_name> - to specify AVDISK table file

-t - please see the '--transform' options description
--transform <source_disk_name> <source_disk_params> - to transform the the disk image (change actual size)
<source_disk_name> - the file name of the disk image to be transformed
<source_disk_params> - the name of the disk from the list of available at the Disk table
The source disk size will changed accordingly the reach the specified parameters.
To specify the transform parameters manually, follow the option below:
--transform <source_disk_name> --blsize <number> --blcount <number>

--shrink - parameter which needs to be EXPLICITLY provided, if the disk size is to be decreased
-k - parameter which needs to be EXPLICITLY provided, if the disk size is to be decreased

--list <full_name> - to display AVDISK table
-l <full_name> - to display AVDISK table

--silent - silent mode running
-s - silent mode running

Return value:
0 - for Success
Non zero - in case of failure

Examples:
mkdskcmd -h
mkdskcmd -l
mkdskcmd -a /opt/charon/utils/mkdsk.vtable -o /etc/rk07.vdisk -d rk07
mkdskcmd -o /etc/custom.vdisk -z 512 -c 16384
mkdskcmd -t /etc/rz22.vdisk rz25 -a /opt/charon/utils/mkdsk.vtable
mkdskcmd -t /etc/rz22.vdisk rz25 -a /opt/charon/utils/mkdsk.vtable -z 512 -c 262134

The "--avtable" parameter is used to work with an alternative disk specification database (or to point to the standard database ("mkdsk.vtable") if it is in a location other than the current directory).

The "--blcount" (blocks count) and "--blsize" (blocks size) switches are used to create custom disk images.

Back to Table of Contents

Transferring disk images

The "mkdskcmd" utility is able to transfer (copy) disk images of one type to a disk image of another type.

This operation is needed, for example, to obtain more free space on a disk image that already contains data.

Note: it is not possible to add more free space dynamically. CHARON-AXP must be stopped before performing this operation.

Info

If a source disk image is larger than the target disk image, the extra data is lost. If the source disk image is smaller, it will be extended and padded with null bytes ('\0').

An example of the syntax follows:

...

where:

  • <source disk file name> - a file name of the disk image to be transferred

  • <source disk parameters> - the name of the disk from the list provided by the "mkdskcmd --list" command execution or the disk geometry specification (see below).

  • --shrink or -k - used in the case where the target disk is transferred to a smaller disk.

Example:

...

It is also possible to specify the disk parameters manually with "--blcount / -c" (blocks count) and "--blsize / -z" (blocks size) switches:

...

Example:

...

Warning

There is a certain delay between the moment when the utility reports that a disk image has been transferred and its actual availability to CHARON. This delay can reach to several minutes in case of very big disks transfers. It happens because the host operating systems needs some time for actual allocation of the enlarged file on HDD.

...

to

...

classpagebreak

...

The "mtd" utility is used to:

...

physical

...

Usage is the following:

...

where the options are:

...

Creates an execution log “file name”.

...

Directs to ignore bad blocks and continue processing without interruption. It implies "-r 0"

...

Enable verbose trace of data transfer (implies "-p")

Example:

...

Use the following syntax to write the content of a tape container to a physical tape:

...

Example:

$ mtd /charon//tape1vtape /dev/st5
tapes.

Back to Table of Contents

...

classpagebreak

...

...

The "hasp_srm_view" utility displays content of CHARON-AXP licenses.

Run the utility with one of the following parameters to see the license(-s) details:

  • "-l" (or without parameters) - CHARON default license details
  • "-all" - all available CHARON licenses details
  • "-key <key number>" - specific CHARON license (defined by its "key number") details

The "hasp_srm_view" utility provides the following functionality:

  • Display the CHARON-AXP licenses details. It is possible to view all available license or some specific one.
  • Collecting license status information
  • Collecting host fingerprint information

Run the utility without any options to display the license details.

...

# hasp_srm_view -help

CHARON Sentinel HASP utility
Copyright: STROMASYS, 2015

Options:
-? or -h or -help - to see help screen

-l - to see CHARON license details (for default key)
-all - to see CHARON license details (for all available keys)
-key <key number> - to see CHARON license details (for specific key)

-c2v <C2V file> - to collect the key status information (C2V file)
-fgp <C2V file> - to collect the host fingerprint information (C2V file)

The specific type of CHARON license defines what switches may be used in each case.

Collecting the "c2v" file can be done only from the CHARON host console.

Remote collection of status information

For remote collection of status information it is recommended to use "ssh" as shown in the following examples:

...

To see the license text on the console:

...

To collect license text to an output file on host server:

# ssh root@localhost /opt/charon/bin/hasp_srm_view > /opt/charon/bin/hasp_srm_view.txt

The "hasp_srm_view" utility always reports the ID and IP address of the host(s) where active licenses are found.

Back to Table of Contents

...

The "hasp_update" is a Sentinel standard utility for license management included in CHARON-AXP kit.

To invoke the "hasp_update" utility login as "root" and use the following syntax:

# hasp_update <option> [filename]

where:

...

Optional path to the C2V file when used with the 'i' option

Uses "stdout" if file name is not specified

Example:

...

# hasp_update u license_update.v2c

Info

We recommend to use this tool only for "Update a Sentinel protection key / attach a detached license" function ("u" option). For the rest use "hasp_srm_view" utility.

Back to Table of Contents

...

Used to display the CHARON license contents, to collect the host system fingerprint and to collect license data required for license updates.

hasp_update

Sentinel standard utility. Used with Charon to install and update licenses.

ncu

Used to dedicate a host interface to CHARON-AXP, to release it back to the host and to manage CHARON virtual interfaces (TAPs

...

)

...

.

Dedication of a host physical interface to CHARON

Login as root and enter "ncu". The following menu will appear:

...

# ncu
CHARON Network Configuration Utility, STROMASYS (c) 2016 Version 1.6 

Interfaces Dedicated to State
---------- ------------ ------------
eth0       host         connected to host
eth1       host         connected from host
lo         host         unmanaged from host

================================================================= 
bridge name bridge id STP enabled interfaces
========================== VLAN =================================
=================================================================

select action:

1 - Dedicate to CHARON 
2 - Release to host
3 - Create Bridge with TAPs
4 - Remove Bridge
5 - Add VLAN
6 - Remove VLAN
7 - Print status
8 - Exit

:> 8

The utility lists available network interfaces (both physical and virtual) and indicates whether they are dedicated to the host or to CHARON and whether they are currently in use by host operating system.

"ncu" offers several options:

  1. Dedicate interface to CHARON
  2. Release interface to host
  3. Create a bridge between a chosen physical network interface and the Linux virtual network and create a number of virtual network interfaces 
  4. Remove the Linux virtual network and all the created virtual network interfaces 
  5. Add VLAN interface
  6. Remove VLAN interface
  7. Print status  - use it to display status of network interfaces and the menu shown above
  8. Exit

In the example above we see 2 network interfaces - "eth0" and "eth1", both of them are dedicated to host, but host uses only the interface "eth0".

Let's dedicate the interface "eth1" to CHARON-AXP.

Enter "1", then type "eth1" and press Enter:

...

Specify the interface to dedicate to CHARON:eth1
Turning off offloading for eth1.. Please wait

select action:

1 - Dedicate to CHARON 
2 - Release to host
3 - Create Bridge with TAPs
4 - Remove Bridge
5 - Add VLAN
6 - Remove VLAN
7 - Print status
8 - Exit

:> 7

...

classpagebreak

Now the interface "eth1" is dedicated to CHARON-AXP:

...

Interfaces Dedicated to State
---------- ------------ ------------
eth0       host         connected to host
eth1       CHARON       disconnected from host
lo         host         unmanaged from host

================================================================= 
bridge name bridge id STP enabled interfaces
========================== VLAN =================================
=================================================================

select action:

1 - Dedicate to CHARON 
2 - Release to host
3 - Create Bridge with TAPs
4 - Remove Bridge
5 - Add VLAN
6 - Remove VLAN
7 - Print status
8 - Exit

Enter "8" to return to console prompt.

Now "eth1" can be used by CHARON-AXP.

Back to Table of Contents

Release of a host physical interface back to host

Login as root and enter "ncu". The following menu will appear:

...

# ncu
CHARON Network Configuration Utility, STROMASYS (c) 2016 Version 1.6  

Interfaces Dedicated to State
---------- ------------ ------------
eth0       host         connected to host
eth1       CHARON       disconnected from host
lo         host         unmanaged from host

================================================================= 
bridge name bridge id STP enabled interfaces
========================== VLAN =================================
=================================================================

select action:

1 - Dedicate to CHARON 
2 - Release to host
3 - Create Bridge with TAPs
4 - Remove Bridge
5 - Add VLAN
6 - Remove VLAN
7 - Print status
8 - Exit

:> 2

Let's say that we want to return the interface "eth1" (currently dedicated to CHARON) back to host. To do that enter "2" then "eth1":

...

Specify the interface to release to HOST:eth1
Connection successfully activated (D-Bus active path: /org/freedesktop/NetworkManager/ActiveConnection/3)

select action:

1 - Dedicate to CHARON 
2 - Release to host
3 - Create Bridge with TAPs
4 - Remove Bridge
5 - Add VLAN
6 - Remove VLAN
7 - Print status
8 - Exit

:> 8

Enter "8" to quit the "ncu" utility.

The interface "eth1" is released back to host system now.

Back to Table of Contents

Creation of a virtual network

Login as root and enter "ncu":

...

# ncu
CHARON Network Configuration Utility, STROMASYS (c) 2016 Version 1.6

Interfaces Dedicated to State
---------- ------------ ------------
eth0       host         connected to host
eth1       host         connected to host
lo         host         unmanaged from host

================================================================= 
bridge name bridge id STP enabled interfaces
========================== VLAN =================================
=================================================================

select action:

1 - Dedicate to CHARON 
2 - Release to host
3 - Create Bridge with TAPs
4 - Remove Bridge
5 - Add VLAN
6 - Remove VLAN
7 - Print status
8 - Exit

:> 3

Enter "3" to create a bridge between the host physical network adapter and the LINUX virtual network interfaces (TAP) and specify the physical network interface ("eth1" in our example) and the number of virtual network interfaces to be created (2 in our example):

Specify the interface to be used for BRIDGE:eth1
How many tap should be created:2
Forming the bridge: ..1..2..3..4..5.. addif tap0 .. addif tap1 ..7..8 done!
Formed bridge br0_eth1 attached over eth1...

select action:

1 - Dedicate to CHARON 
2 - Release to host
3 - Create Bridge with TAPs
4 - Remove Bridge
5 - Add VLAN
6 - Remove VLAN
7 - Print status
8 - Exit

...

 

...

classpagebreak

Now enter "7" to see the created virtual interfaces:

...

Interfaces   Dedicated to    State
----------   ------------    ------------

eth0           host            connected to host 
eth1 bridge connected to bridge
lo host unmanaged from host
tap0 CHARON connected to host
tap1 bridge connected to bridge
=================================================================
bridge name bridge id STP enabled interfaces
br0_eth1 8000.768e1ea091d9 no eth1
tap0
tap1
========================== VLAN =================================
=================================================================

select action:

1 - Dedicate to CHARON 
2 - Release to host
3 - Create Bridge with TAPs
4 - Remove Bridge
5 - Add VLAN
6 - Remove VLAN
7 - Print status
8 - Exit

:> 8

In the example above we see 2 virtual network Interfaces "tap0" and "tap1" connected to the created bridge. The physical network interface "eth1" is used for the bridge to the virtual network interfaces.

The interfaces "tap0" and "tap1" are ready to be used in CHARON configurations - they do not need to be additionally dedicated to CHARON.

Enter "8" to quit "ncu" utility.

Back to Table of Contents

...

classpagebreak

Removal of a virtual network

Login a root. Start "ncu" utility:

...

# ncu

CHARON Network Configuration Utility, STROMASYS (c) 2016 Version 1.6

Interfaces   Dedicated to    State
----------   ------------    ------------

eth0           host            connected to host 
eth1 bridge connected to bridge
lo host unmanaged from host
tap0 CHARON connected to host
tap1 bridge connected to bridge
=================================================================
bridge name bridge id STP enabled interfaces
br0_eth1 8000.768e1ea091d9 no eth1
tap0
tap1
========================== VLAN =================================
=================================================================

select action:

1 - Dedicate to CHARON 
2 - Release to host
3 - Create Bridge with TAPs
4 - Remove Bridge
5 - Add VLAN
6 - Remove VLAN
7 - Print status
8 - Exit

:> 4

Enter "4" then enter the interface name that is a bridge to the Linux virtual network on this host ("eth1" in our example):

...

Specify the phys interface used for BRIDGE:eth1
Cleanup bridge br0_eth1 with ip over eth1...
Removing the bridge: ..1..2 delif eth1
delif tap0
delif tap1
..5..6..7..8 done!

select action:

1 - Dedicate to CHARON 
2 - Release to host
3 - Create Bridge with TAPs
4 - Remove Bridge
5 - Add VLAN
6 - Remove VLAN
7 - Print status
8 - Exit

:> 8

Enter "8" to quit "ncu" utility.

Back to Table of Contents

Adding VLAN interface

Login a root. Start "ncu" utility:

...

# ncu

CHARON Network Configuration Utility, STROMASYS (c) 2016 Version 1.6

Interfaces   Dedicated to    State
----------   ------------    ------------

eth0       host         connected to host
eth1       host         connected to host
lo         host         unmanaged from host

================================================================= 
bridge name bridge id STP enabled interfaces
========================== VLAN =================================
=================================================================

select action:

1 - Dedicate to CHARON 
2 - Release to host
3 - Create Bridge with TAPs
4 - Remove Bridge
5 - Add VLAN
6 - Remove VLAN
7 - Print status
8 - Exit

:> 5

Enter "5" then enter:

  1. The phisical interface name to be used for creating VLAN
  2. The ID of the VLAN device
  3. IP address of the VLAN device. Skip this step if no IP is required
  4. Network mask of the VLAN device. Enter for no network mask.

...

Specify the phys interface used for VLAN:eth1 
Specify the id of VLAN device (<4095):111
Specify the ip address of VLAN device or empty string for no ip address: 192.168.1.100
Specify the netmask address of VLAN device or empty string for no netmask: 225.225.225.0

select action:

1 - Dedicate to CHARON 
2 - Release to host
3 - Create Bridge with TAPs
4 - Remove Bridge
5 - Add VLAN
6 - Remove VLAN
7 - Print status
8 - Exit

:> 8

Enter "8" to quit "ncu" utility.

Back to Table of Contents

Removing VLAN interface

Login a root. Start "ncu" utility:

...

# ncu

CHARON Network Configuration Utility, STROMASYS (c) 2016 Version 1.6

Interfaces   Dedicated to    State
----------   ------------    ------------

eth0       host         connected to host
eth1       host         connected to host
lo         host         unmanaged from host

================================================================= 
bridge name bridge id STP enabled interfaces
========================== VLAN ================================= 
eth1.111
=================================================================

select action:

1 - Dedicate to CHARON 
2 - Release to host
3 - Create Bridge with TAPs
4 - Remove Bridge
5 - Add VLAN
6 - Remove VLAN
7 - Print status
8 - Exit

:> 6

Enter "6" then enter the VLAN interface for remove:

...

select action:

1 - Dedicate to CHARON 
2 - Release to host
3 - Create Bridge with TAPs
4 - Remove Bridge
5 - Add VLAN
6 - Remove VLAN
7 - Print status
8 - Exit

:> 8

Enter "8" to quit "ncu" utility.

Back to Table of Contents

...

The "CHARON Guest Utilities for OpenVMS" (CHARONCP) package contains several utilities for managing virtual tapes, changing the emulator speed and creating useful definitions for that operations.

This set of utilities is located in the "charoncp011.vdisk" disk file in the "/opt/charon/disks".

Back to Table of Contents

Installation

Specify this image in the CHARON configuration file, boot from the system disk and mount the disk with the following OpenVMS command:

...

* Are you satisfied with the backup of your system disk [YES]? YES
* Where will the distribution volumes be mounted: <device name>:[000000.CHARONCP011.KIT]

Enter the products to be processed from the first distribution volume set.
* Products: CHARONCP011

Select all the components included to the package:

...

Component Selection

Select the CHARONCP components you wish to install from the menu below.
An asterisk appears next to the packages that have already been
selected. You can remove a package from the list by selecting it
again. You may enter more than one selection by separating your
choices with commas.

1. [*] CHARONCP Guest Utility (REQUIRED)
2. [*] Compatability Utilities
3. [*] Install DCL Commands & Help

4. Exit

* Your choice [4]: 4

Proceed with installation using all the default options.

Once the installation is completed, update "SYSTARTUP_VMS.COM" file with the following line:

...

After that the package will be loaded automatically on startup.

Back to Table of Contents

Performance optimization

CHARON takes 100% of host CPU even in case of idle state of guest OpenVMS operating system. To get rid of such resources consumption there is a specific option provided by CHARON Guest Utilities - "idle" mode.

...

Loads the OpenVMS idle loop detection software. This allows CHARON to detect when the emulated CPU(s) are idle and use the host power saving instructions to reduce power usage.

...

Virtual tapes management

Specify mapping to tape container in the following way in the CHARON configuration file:

...

Example:

...

Once it is done using the following commands it is possible to manage virtual tapes attached to CHARON:

...

Create the specified host-file (if it does not already exist) and attach it to the specified virtual tape device.

Example:

$ CHARONCP SET MAGTAPE MKA600: /LOAD="backup_01.vtape"

...

Detach any file currently attached to te specified virtual tape device.

Example:

$ CHARONCP SET MAGTAPE MKA600: /UNLOAD

Possible errors:

...

The filename specified as a value to the qualifier /LOAD was either too long or does not have a file extension of ".vtape".

...

Attempting to execute a SET MAGTAPE/LOAD when a file is already attached.

Perform a SET MAGTAPE/UNLOAD first.

(info) If some tape container has been already specified in the CHARON configuratioon file use the command "CHARONCP SET MAGTAPE <device> /UNLOAD" to unload it first.

Back to Table of Contents

Defining keys

It is possible to define certain keys on the terminal keyboard for fast access to the CHARONCP functionalilty while you are in CHARONCP:

...

$ CHARONCP
CHARONCP> DEFINE /KEY <key-name> <equivalence-string>

...

Defines an equivalence string and a set of attributes with a key on the terminal keyboard.

You can have a set of keys defined automatically for use with the CHARONCP utility by placing DEFINE/KEY commands in the file SYS$LOGIN:CHARONCP_KEYDEFS.INI

Example:

$CHARONCP
CHARONCP> DEFINE /KEY F1 "SET MAGTAPE MKA600: /UNLOAD"

...

Displays key definitions created with the DEFINE/KEY command. Refer to the DCL help entry for SHOW KEY for further information.

Example:

$CHARONCP
CHARONCP> SHOW KEY F1
DEFAULT key state definitions:
F1 = "set magtape mka600: /unload"
CHARONCP>

(info) For more information refer to the OpenVMS DCL Dictionary (DEFINE/KEY section).

Back to Table of Contents

Displaying version

...

Displays the CHARONCP package version number and architecture. This can be useful for customers reporting issues with the CHARONCP software.

Example:

$ CHARONCP SHOW VERSION

CHARONCP version id is: V1.1

...

CHARON Guest Utilities for OpenVMSUsed to manage virtual tapes and CHARON performance.

All these utilities (except for CHARON Guest Utilities for OpenVMSare invoked from the Linux console command line.