KBCOMMON:KB-CSSstyle

Page Properties
hiddentrue


ProductCHARON-AXP/SMA
Version2.3.3
Operating systemWindows
Document typeRelease Notes
Document number60-17-034-001005
Last update 
State

Under constructionReleased


(info) (info) Please review this document before proceeding with installation of CHARON-AXP/SMA(+)

This manual contains the release notes for the CHARON-AXP/SMA for Microsoft Windows 2.23.40 3 virtualization software.  It describes any features, restrictions, changes or additions made to CHARON-AXP/SMA for Microsoft Windows and includes information that is not provided elsewhere in the User's Guide.

...

Stromasys S.A.

Avenue Louis-Casai 84 - 5th Floor

1216 Cointrin

Switzerland

Table of Contents

Table of Contents
maxLevel2
minLevel2

's Guide.

Revision/Update Information:

Last update:  

Software Version:CHARON-AXP/SMA for Microsoft Windows Version 2.3.3
Include Page
KBCOMMON:KB-Header
KBCOMMON:KB-Header

Stromasys S.A.

Avenue Louis-Casai 84 - 5th Floor

1216 Cointrin

Switzerland

.

Div
classnoprint

Table of Contents

Expand

Table of Contents
maxLevel2
minLevel2


New Features and Changes in 2.3.3

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.3.3, produced on 01-Mar-2017.

Important note

  • (warning) All previous versions of CHARON-AXP/SMA have to be uninstalled before installing version 2.3.3

Changes

  • Redesigned license module to conform with CHARON-AXP and CHARON-VAX license specifications including checksum thus allowing CHARON-AXP/SMA to run on the same server as CHARON-AXP and/or CHARON-VAX,
  • USB reset support when encountering license session error,
  • Updated NDIS (network) driver to the latest version,
  • Windows 10 support
  • Windows 2008 R2 requires SP1 and the KB3033929 patch installed


Note

With recent versions of Windows 10 (21H1 for example), Windows will crash with blue screen during the installation of the license driver. This is due to the old version of the driver provided with the kit. Please contact us to get the Charon License Utility and install the latest available driver. Then restart the Charon-AXP/SMA installation.

(warning) Do not install the driver provided by Gemalto, the driver must be provided by Stromasys.

Bug Fixes

None.

New Features and Changes in 2.2.40

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.2.40, produced on 22-DEC-2014.

Changes

  • Detect different valid HASP license dongle without restarting emulator.
  • Support Sentinel SL license.

  • Support Windows 8 and Windows 2012 R2.
  • Updated User's Guide.

Bug Fixes

  • Solved problem in v2.2.39 with Ethernet "memory" model configuration.
  • Sometimes OpenVMS can't resume the execution after enters the SRM console with "Ctrl + P".
  • "Auto Start" and "Auto Restart" are not working properly.
  • DEC3000 prints too much software license information in its log.
  • Wrong expiration information reported in log file when unlimited key is used: "license: Time limited key /".
  • Model start once, expiration timer of backup key decreases twice.
  • There is no warning message in log file before license's expiration.
  • A lot of unknown devices reported in OpenVMS when list buses with command "mc sysman io show bus".
  • Under old Windows 2003, SMA+ can't handle tape block size larger than 64KB.
  • Switch user account to run CHARON-AXP/SMA Plus for the first time will cause the running emulation terminated.
  • DEC3000 instance crashed due to unknown HASP error 21.
  • Emulator crashed if CDROM is configured and doesn't exist on host.
  • CHARON crashed on HASP unknown error 27
  • SMA crashed on socket serial line error
  • Only the first two tape savesets can be displayed

  • Side-by-side error 33 occurs when start NCC tool.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.2.39, produced on 18-SEP-2013.

Changes

  • Updated NDIS drivers.

Bug Fixes

  • Fixed a network bug lying in DEC3000.

  • Solved a issue which occurs when uninstall SMA production.
  • Fixed the bug that device can't be recognized when the type of SCSI device is 3

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.2.38, produced on 24-MAY-2013.

Changes

  • Changed configuration format of physical drive.

  • Support Windows server 2012.

Bug Fixes

  • Fixed the bug that massive multicast packages cause RX queue overflow.

  • Fixed a vtape bug.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.2.37, produced on 25-DEC-2012.

Changes

  • Changed license from HASP HL to Sentinel HASP. A license update is required. Stromasys might request a c2v file taken from HASP license dongle in order to issue a license update. Please use "Key Update" item from CHARON-AXP tray icon to collect a c2v file and apply a v2c license update.

Bug Fixes

  • Fixed the bug that expiration date cannot be displayed in log.
  • Fixed an uninstall bug.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.2.36, produced on 23-NOV-2012.

Changes

  • Product version had been changed to 2.2

  • SCSI commands: reserve and release are supported.

Bug Fixes

  • Fixed a NDIS driver issue.
  • Fixed a console error.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.35, produced on 03-MAY-2012.

Changes

  • Updated the utility 'HASP_HL_VIEW'.

Bug Fixes

  • Fixed emulator hang relating to bypass device with high IO overhead.
  • Fixed the problem with virtual disk configured with ISO image.
  • PBXDA serial line can work in Tru64 now.
  • Fixed the problem with PBXDA serial line on models with multi-CPU.
  • Fixed the problem with massive performance loss after command 'stop /cpu'.
  • Fixed parallel port issue.
  • System time delay on model DEC3000 is solved.
  • Fixed delay problem of reading save sets on tape.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.34, produced on 20-MAR-2012.

Changes

  • Updated the utility 'key update', the key update via RDP is supported.

  • Added the utility 'Network control center' to the menu.

Bug Fixes

  • Fixed the network issue.

New Features and Changes in 2.1.33

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.33, produced on 18-JAN-2012.

Changes

  • Added support for checking two kinds of feature id of license at the same time.
  • Added support for different lock size for LDx_L and STx_C instructions.

  • CHARON Packet Protocol (NDIS6) was updated to v6.2.

Bug Fixes

  • Fixed the bug that command "psradm -f" can't work properly on Tru64 UNIX.

  • Fixed the problem parallel port.
  • Resolved the problem that tape can't support block size larger than 64KB.
  • Corrected AMASK value.
  • Fixed the crash caused by setting MAC addresss at the CFG file.
  • Fixed the problem system disk shadowing fail to boot when multiple CPUs are configured.
  • Fixed problem configuration keywords are case sensitive.
  • Fixed the crash with model DEC3000.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.32, produced on 25-AUG-2011.

Changes

  • DEC3000 emulator version 2.1 is included into SMA product now.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.31, produced on 16-MAY-2011.

Bug Fixes

  • Fixed problem caused by new network mode under ndis5 driver.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.30, produced on 05-MAY-2011.

Changes

  • Modified network mode making 'CHPACK' as default network mode.
  • Added license agreement in installation procedure.

Bug Fixes

  • Medium changer device can be identified now.
  • Fixed problem of pool of request.
  • Resolved the problem that emulator crashes when performs format command.
  • Fixed problem of physical serial port.
  • Corrected incorrect chip type of network adapter.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.29, produced on 01-APR-2011.

Changes

  • Added uninstallation guide of CHARON-AXP/SMA Plus in help document.
  • Support a new communication mode between emulator and ndis driver, which improves some network performance.
  • Updated HASP device driver to the latest version 5.95.

Bug Fixes

  • iSCSI disk can be recognized rightly in Tru64.
  • Now device type of physical tape can be shown correctly in OpenVMS.
  • Errors occur during tape reads is handled correctly.
  • Corrected incorrect configuration of LPT device in sample config file.
  • Resolved a rare problem that emulator with 2 CPUs crashes during OpenVMS is rebooting.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.28, produced on 20-AUG-2010.

Changes

  • Windows Server 2008 R2 and Windows 7 (64 bit) are now fully supported
  • SRM command D SIRR C implemented.
  • Booting from the tape implemented.

  • Documentation regarding direct SCSI access updated.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.2.36, produced on 12-JUL-2010.

Changes

  • Documentation updated regarding CD/DVD image support.
  • Documentation updated regarding virtual network usage with Microsoft Loopback Adapter.

Bug Fixes

  • Wrong error message that appeared on successful installation of CHARON-AXP has been removed on Windows 7.
  • Appending to a log file now functions properly.
  • The correct message is displayed when CTRL-P is pressed.
  • PuTTY now starts automatically when configured to do so as part of a windows service that is automatically started.
  • PuTTY now pops up properly when the emulator is started from the command line.
  • on Windows Server 2008 R2 and Windows 7 PuTTY now pops up properly when the emulator is started over RDP.
  • A false error message is no longer displayed when installing Charon-AXP/SMA (Plus) on Windows Server 2008 (R2) and Windows 7.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.26, produced on 07-JUN-2010.

Bug Fixes

  • MKimage utility now functions properly
  • Any user in the Administrators group can now start Charon-AXP on Windows Server 2008(R2) and Windows 7.
  • The console command "set bootdef_dev <device> now works properly.
  • PuTTY now pops up automatically on Windows Server 2008, Windows Vista, Windows 7, and Windows Server 2003.
  • The SRM console command "continue" now functions properly.
  • Fixed vtape file locking problem seen on Tru64 UNIX.
  • Included the current hasp key driver, haspdinst.exe.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.25, produced on 22-MAR-2010.

Changes

  • SMA has been qualified for Windows Server 2008.

Bug Fixes

  • Fixed ndis6 driver bug (memory leak).

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.24, produced on 19-OCT-2009.

Changes

  • Only display VMS bugcheck in the logfile if it is fatal.

  • Added the signed NDIS6 driver.
  • The disk caching defaults to off.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.23, produced on 07-SEP-2009.

Changes

  • Uniform configuration files between SMA and the other emulators.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.22, produced on 08-JUL-2009.

Changes

  • Charon-AXP/SMA (Plus) is now Windows 2008 ready.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.21, produced on 22-JUN-2009.

Changes

  • Changed the licensing to eliminate the C2V files.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.20, produced on 04-MAY-2009.

Bug Fixes

  • Fixed problem SCSI Passthrough tapes.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.19, produced on 02-APR-2009.

Bug Fixes

  • Fixed problem BYPASS driver.

  • Fixed modem status signals within serial lines.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.18, produced on 17-MAR-2009.

Bug Fixes

  • Fixed problem with queue instructions.

  • Fixed problem with response queues.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.17, produced on 08-FEB-2009.

Bug Fixes

  • Fixed problem with USB floppy drives.

  • Fixed problem with licensing.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.16, produced on 30-JAN-2009.

Bug Fixes

  • Fixed problem with USB floppy drives.

  • Fixed problem with invalidation of DIT pages.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.15, produced on 27-JAN-2009.

Bug Fixes

  • Fixed problem with invalidation of DIT pages.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.14, produced on 13-JAN-2009.

Bug Fixes

  • Fixed check when opening the logfile within the service.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.13, produced on 07-JAN-2009.

Bug Fixes

  • Fixed AS200 Model within the user interface.
  • Problem when using a bypass disk as a quorum disk, updated Bypass Driver to version 1.4
  • Makedisk displayed incorrect sizes

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.12, produced on 19-DEC-2008.

Changes

  • Added partial support for SCSI pass through for ATAPI devices.

  • Added support for disk geometry parameters. These are advanced options that can lead to disk corruption, when used incorrectly. See the manual for usage.
  • Added support for disk vendor/product/revision parameters. See the manual for details.

Bug Fixes

  • SCSI pass through for unit with sector size other than 512 did not work.

  • Tsunami emulator crash with 256MB memory.
  • TOY clock in unix always gives "preposterous time"
  • When the TOY clock filer removed, Windows time is used instead of zero time. With zero time VMS would ask to input the time.
  • External interrupt delivery was sometimes inefficient.
  • RAM disk did not work

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.11, produced on 29-SEP-2008.

Changes

  • Changed Installer to display the version number.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.10, produced on 16-SEP-2008.

Changes

  • Switched to new HASP runtime (version 5.50).

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.9, produced on 07-SEP-2008.

Changes

  • Changed floating point routines.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.8, produced on 14-AUG-2008.

Bug Fixes

  • Incorrect thread affinity fixed.

Changes

  • Added extra licensing information.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.7, produced on 04-AUG-2008.

Changes

  • Changed Manufacturer name to Stromasys.

  • Changed Icons to the new CHARON Icons.
  • The SRM wil now display the actual tape and disk information.
  • Fixed detection of CDROM devices/virtual images.
  • Added a new tool hasp_hl_view to view the contents of the license key.
  • New Bypass driver included (v1.2) which supports VMS6.2. This Bypass driver cannot be used for booting VMS6.2.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.6, produced on 17-JUL-2008.

Bug Fixes

  • Physical serial lines parity setting fixed.

  • PBXDA parity setting fixed.
  • Fixed loading of PBXDA for slots 1-4, when using more than 4 controllers.
  • Fixed handling of DTR/RTS and stopbits for physical serial lines
  • Fixed handling of line characteristics for tta0

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.5, produced on 17-JUN-2008.

Changes

  • In the release 2.0.x the file tape was auto-loaded. That means that if the file is available it is loaded automatically. In earlier 2.1.x this functionality was disabled because it caused problems by multi-volume backups. Namely, if the tape size reaches maximum, it unloads the tape and immediately checks for new volume load. It sees the same tape file and overwrites it with the new volume. In this release the user has an option to control autoload. By default we chose the safe variant, for example, MKA500.autoload=off. Users that are sure that there is no multivolume backup done and that the tape file does not overflow the disk can explicitly specify the auto load option, for instance, MKA500.autoload=on.

  • VMS Bugcheck, halt and invalid operations conditions are now logged.

Bug Fixes

  • SMP DIT page invalidation fixed. This caused random crashes.
  • DMA DIT invalidation for disk devices. This caused random crashes.

  • SRM crash command does not work after halt instruction.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.4, produced on 13-MAY-2008.

Changes

  • Support for SMP ES40 for early VMS versions, starting from 7.1-2.

  • Added support for a shared memory based network backend. This network can be used to connect emulator instances running on the same host. Configurations example:

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.3, produced on 15-APR-2008.

Bug Fixes

  • Corrected SoftTrap handling.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.2, produced on 11-APR-2008.

Changes

  • We now support the following models:
    • Digital DEC 3000 Model 400
    • DIGITAL AlphaStation 200, 250, 500, 600
    • DIGITAL AlphaServer 300, 400, 800, 1000, 1200, 2000, 2100, 2000, 2100, 4000, 4100, 8200, 8400
    • DIGITAL Personal Workstation au
    • DIGITAL Modular Computing Components (DMCC)
    • Compaq AlphaStation XP900, XP1000
    • Compaq AlphaServer DS10, DS20, DS25, ES40, ES45

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.1.1, produced on 22-FEB-2008.

Changes

  • A new version (V 1.2) of the IDLE mechanism is available and it is advised to upgrade to this version.

Bug Fixes

  • Crash when running VMS monitor system, Floating point bug.

  • Removable disk support for bypass disks.
  • Error handling when using more than 31 PCI slots.
  • VIRBND was enabled. Now disabled.
  • Incorrect fault-on-execute failing address.
  • DEC3000 reboot problems.
  • CPU attention check missing.
  • PBXDA/DIGI/EPCA caused system hang-up.
  • Service crash when starting without a key.
  • Clearing of SRM variables using set <varname> "".

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.0.1, produced on 03-DEC-2008.

Bug Fixes

  • The configurations within the User Interface are sorted on the configuration name.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 2.0.0, produced on 18-DEC-2007.

Changes

  • CPU performance improvements. The performance figures highly depend on the application. Integer arithmetic intensive applications can gain up to 100% on Intel and up to 50% on AMD. The floating point performance increase is about 5-10%.

  • The disk container file caching is now by default disabled. This makes writes more reliable in case of power failures and enables shared access in a cluster environment. To enable caching use read_cache and write_cache options. Also, the container file memory mapping option improves performance. However, by power failures some of the write data might be lost.

...

  • Multiple instances of the emulator on a single machine are supported. Please see the documentation for details.
  • Configuration file is made case-insensitive.
  • Idle package updated. From now on it supports all VMS from 6.2. The idle driver resides on the disk image drivers.vdisk included in the emulator kit.
  • Network card model can be specified. You can choose from DE435 (default), DE450, and DE500.
  • Multiple PBXDA devices are now supported. The driver limit is 7.
  • Special fast IO facility called "disk IO bypass" is added. It significantly increases disk IO throughput. The bypass requires installing a special driver in VMS. The driver resides on the disk image drivers.vdisk included in the emulator kit. Please see manual for more details.

Bug Fixes

  • SCSI pass through tapes and Windows tape did not work in Digital UNIX.

  • SRM boot* and booted* variables were not correctly used in system restarts. For instance, this caused DU installer to reboot from the CD instead of the just installed disk.
  • Long network interface names caused overflow of some logging buffers.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.2.2, produced on 28-SEP-2007.

Bug Fixes

  • SRM auto_action and boot_dev bug fixed.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.2.1, produced on 30-AUG-2007.

Bug Fixes

  • Fixed initialization of the serial lines.

  • Fixed setting of the baud rate.
  • DEC3000: Reinitialized console after leaving the OS. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.2.0, produced on 23-AUG-2007.

Changes

  • Extended SRM console support.
  • Charon-AXP DMCC, Charon-AXP DEC3000 and Charon-AXP AlphaServer have been merged within a single product.

  • Digital Unix/Tru64/OSF1 beta level support for versions 3.2C to 5.1B
  • Changes to the configuration file:
  • The system type is given with the line model <system type> 
    Examplemodel AS4000
  • The network adapters are renamed from EWx to EWx0.
  • The set_env SRM parameters settings are no longer needed.
    This functionality is provided with the new SRM console
  • Start of the emulator and SRM console using the command power on .

Bug Fixes

  • Real SCSI disk support with Tru64.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.1.7, produced on 24-JUL-2007.

Bug Fixes

  • Minor bug fixes.

New Features and Changes in 1.1.6

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.1.6, produced on 23-JUL-2007.

Changes

  • Now not only time but also the date is logged 

Bug Fixes

  • Issues with memory above 4GB. Now up to 8GB is supported. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.1.5, produced on 26-JUN-2007.

Bug Fixes

  • Bugcheck in x86asm.cxx:127. Code buffers are too small for some applications. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.1.4, produced on 01-JUN-2007.

Changes

  • Switched to HASP HL 5.22 driver. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.1.3, produced on 30-MAY-2007.

Changes

  • Emulator internal memory layout changed because to support some configurations.

  • Putty release switched from 0.58 to 0.60 

Bug Fixes

  • Disk images not multiple of 512 bytes caused bug check. Now truncated. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.1.2, produced on 11-MAY-2007.

Bug Fixes

  • PAL IMB bug fixed.
  • SRM variable bugs fixed.
  • HWRPB bugs fixed.
  • SCSI selection with the target id equal to the initiator id bug fixed.
  • Some unimplemented SCSI messages implemented.
  • Some unimplemented ISP1040 commands implemented.
  • The NCR SCSI controller message handling bugs fixed.
  • Problems accessing memory above 4GB. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.1.1, produced on 27-APR-2007.

Changes

  • Loaded but unspecified network interfaces are mapped to a dummy. Network interfaces specified but not found cause an error and stop the emulator.

  • A list of known disk geometries added. The list includes geometries for all supported disk image file sizes. This should fix some geometry related problems.

    Note

    In this release the known vendor and product ids are still not passed to VMS. So VMS still displays some fake disk name. This will be fixed in the near future.


Bug Fixes

  • Removable devices sometimes do not see new medium.

  • Sometimes CDROM read incorrect data.
  • Various SRM bugs. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.1.0, produced on 13-APR-2007.

Changes

  • Reworked the disk device recognition mechanism. For instance, the earlier version did not support DVD and USB devices with changeable media. This version should work fine with any windows disk device. Rewritable and write-once functions are still not supported.
  • Disk geometry for file and memory mapped disks changed to fit VMS-supported geometry of spt*tpc*cyls ~ byte*byte*word.

  • Accelerated the disk Physical Drive IO for disks with the blocks size of 512 bytes. This does not include the CD/DVD drivers, thus, which have block size of 2k.
  • Accelerated the PCI emulation.
  • Memory mapping reworked. Now the emulator uses a fixed amount of memory for the emulated pages. The memory is mapped at fixed address.
  • Emulator now stops when it cannot map disks, tapes or Ethernet devices.
  • Since the introduction of the Asynchronous DIT (Dynamic Instruction Translation) the CPU performance degraded due to the synchronization overhead. Tuned the performance back to the original value.
  • Improved the DIT code page reuse by implementing the last-recently used algorithm.
  • Changed the thread affinities. The emulator CPU thread now runs on the host CPU1, and the emulator DIT thread runs on CPU0. The CPU1 has less chance to run Windows code, which improves the performance.

Bug Fixes

  • CPU multiplication with overflow bug fixed.

  • CPU CVTTQ/SVI overflow bug fixed. Integer register numbers where marked as changed instead of the floating pointer registers.
  • Windows tape device mapping fixed: the verification phase of backup was too slow.
  • DEC3000 sometimes bugchecks when the tape loading takes long. This is because some connected (non-disconnected) SCSI command implementation exceeds the limit of the NCR driver (e.g. TEST UNIT READY). Fixed by making the tape status update asynchronous.
  • The serial console (OPA0) did not support setting of the line characteristics like baud rate.
  • Ethernet shared mode emulated permanent address was the same as the real one. This prevents working of TCP/IP in the emulator and in Windows. Now the emulator returns permanent MAC address which is equal to the real permanent MAC address with the last two octets incremented by one. Note that the emulated permanent MAC address can be explicitly specified by the macaddr option.
  • The emulator showed non-exiting PCI devices because the invalid PCI access returned -1 instead of generating the machine check. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.22, produced on 07-MAR-2007.

Changes

  • Added BETA-level support for windows tape device mapping. In this case the emulator works with the tape not via SCSI PASS THROUGH mechanism, but via Windows tape API functions.

    • Disadvantages: there is an emulation and windows layer between VMS and the hardware that can compromise performance and block access to some advanced tape functionality.

    • Advantages: Not only SCSI tapes supported by VMS can be used. For instance, USB tapes can be used. For SCSI tapes, the user does not have to know the SCSI id of the tape: if there is only one tape in the system, its name is \\.\Tape0. Thus, it is easier to configure.

...

Panel
bgColor#ffffff
titleBGColor#f0f0f0
titleConfiguration Example


Load DKA0
DKA0.image="my.vdisk"
DKA0.mapped=yes


Bug Fixes

  • Emulator was reporting incorrect disk geometry: one sector too many. This caused failures reading/writing the last sector. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.21, produced on 20-FEB-2007.

Changes

  • Added support for OpenVMS remote boot via MOP.
    • Use "boot EWA" to boot from EWA network card and BOOT_FILE SRM variable to specify boot file if needed.
    • On DEC3000 use boot ESA or ECA, ECB, ECC.
  • Station MAC address emulation is changed. This change was needed to make the remote boot identification possible.
    • The emulated permanent address is equal to the real permanent address. It can be redefined like EWA.macaddr="00-01-02-03-04-05"
    • The emulator starts with the physical address equal to the permanent address.
  • Extra MAC address changing mode added to the system: EXCLUSIVE_ASYNC. This mode used asynchronous address change. While the address is changes the emulator does not receive packets and drops the send requests. The emulator is not blocked waiting for address change to complete. Please check the documentation.
    • No promiscuous mode needed for the address change. This is beneficial for busy networks where many promiscuous packets come across.
    • Some adaptors (Broadcom NetXtreme Gigabit Ethernet adaptor) require a very large time to change the MAC address, more then 20 seconds. Clusters may timeout with such an interval. Please consider the EXCLUSIVE_DELAYED mode instead.
    • EXCLUSIVE_DELAYED mode remains default.
  • Terminal emulator processes are now stopped automatically. To avoid change this behavior specify OPA0.stop_process=no
  • Terminal emulator configuration options changed:
    • OPA0.baud_rate option removed because the speed is selected by VMS. 
    • OPA0.emulate_speed option is added to turn of the speed emulation delays for the telnet/socket lines off.
  • BETA-level support for Digital Unix added. Known problems:
    • DEC3000: Only 4.x versions are support. Version 3.2 does not work yet (Versions 5.x do not run DEC3000).
    • Direct SCSI mapping for disks does not work. It works for tapes. 
    • SRM functionality is more limited then that of VMS. In particular reboot does not work properly.
    • Remote boot is not supported.

Bug Fixes

  • DEC3000 mapping of TTA1 to a physical port does not work.

  • Serial line characteristics are not set on the physical lines. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.20, produced on 17-JAN-2007.

Changes

  • DEC3000: SCSI disconnect-reconnect functionality implemented. This enables usage of slow physical devices like tapes and improves the IO response time on system with high IO load.
  • CDROM locking support added.
  • Added UI menu option to edit the current configuration file.
  • Added logging of the license key information at the emulator startup.
  • Socket serial line input speed control added. This is needed to make copy-paste to the terminal emulator possible.

...

    • To disable use (maybe needed for binary lines)

OPA0.baud_rate=0

Bug Fixes

  • DEC3000 physical tape support.
  • Serial line bugs: timeout and corrupted output.
  • SCSI pass-through: support for large transfers added.
  • IDLE support fixed: sometimes the emulator hung when using IDLE. 
    Known bugs:
  • Serial line characteristics are not passed correctly from VMS to the host serial line (COM port). This is important for hardware COM port mappings. Workaround: use the Windows command prompt "mode" command to set the COM port characteristics that match those used by VMS.
  • In some cases the SRM console Ctrl-P/boot command combination does not work as expected. Workaround: stop the emulator and start it again with the new boot argument.
  • DEC3000 SCC0.B (TTA1) port does not work correctly.
  • Network boot is not implemented. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.19, produced on 08-DEC-2006.

Bug Fixes

  • On certain types of the host systems the emulator hangs. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.18, produced on 30-NOV-2006.

Bug Fixes

  • RDB performance on the emulator is very poor. The emulator had this problem with on-the-fly-generated code. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.17, produced on 14-NOV-2006.

Bug Fixes

  • Cluster reboot fails. 

New Features and Changes in 1.0.16

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.16, produced on 07-NOV-2006.

Bug Fixes

  • Virtual tape is too slow.
  • Disk offline on CDROM attached to ISP1040 controller.
  • Emulator crashes with 1536MB emulated memory.
  • Console output is not complete in SRM console mode.
  • Invalid DECNET address output removed.

Limitations

  • Cluster node reboot fails. Workaround: shutdown the emulator, stop it, and start again.

  • Cannot boot from a different disk after halting. Workaround: stop the emulator, start it and boot again from a different disk.
  • SRM variable AUTO_ACTION is not implemented correctly. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.15, produced on 30-OCT-2006.

Bug Fixes

  • DEC3000: a disk goes offline when using two SCSI controllers.
  • PCI based systems: VMS 7.1, 7.1-1h2 does not install.
  • Incorrect virtual tape file mark positioning.
  • Seek errors with disks mapped to real disks (CDROM).

  • PBXDA dir hangs.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.14, produced on 11-OCT-2006.

Bug Fixes

  • DEC3000 problem booting some VMS releases solved.

  • Installer problem with removing previous version solved 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.13, produced on 10-OCT-2006.

Bug Fixes

  • Large block size bug for virtual tape.

  • Read-only virtual disk image files did not mount read-only causing problems. Now read-only image files are exposed as CD's.

Changes

  • Early VMS version support added
    • AS1000: 6.2-1h3 and later
    • AS4000: 6.2-1h3 and later

    • DEC3000: 6.1 and later
    • Station: 6.2-1h3 and later
  • Multi-LUN support for SCSI devices. See the help for details. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.12, produced on 11-SEP-2006.

Changes

  • telnet serial line support has been split in two parts:

    • "telnet" serial line – ASCII based connection to a telnet client
    • "socket" serial line – RAW BINARY mode TCPIP connection 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.11, produced on 08-SEP-2006.

Bug Fixes

  • Virtual 2nd mount problem. Tape dismount unloaded the tape and the tape could not be loaded any more. Now the tape is automatically loaded by the next mount command. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.10, produced on 06-SEP-2006.

Bug Fixes

  • Virtual tape READ POSITION bugs fixed.

Changes

  •  PuTTY is now the default terminal emulator. Putty is a freeware terminal emulator included in the CHARON-AXP setup kit.

Limitations

  • When the emulator exits PUTTY shows an error box: "Network Error: Software caused connection abort".
  • Backspace and delete do not work in the SRM console. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.9, produced on 31-AUG-2006.

Bug Fixes

  • Virtual tape bugs fixed in DEC3000. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.8, produced on 29-AUG-2006.

Changes

  • Added the dongle key update utility (hasprus.exe) to the emulator UI menu.

Bug Fixes

  • Bug in writing the second backup on a virtual tape fixed for AS4000 and AS1000 products
  • Fixed the bug: UETP test does not work for dummy network mapping.

  • Bugs in the installer.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.7, produced on 04-AUG-2006.

Changes

  • Switched from PUTTY to HYPERTERM as the default terminal emulator. The problem with PUTTY is that the "set password" does not properly work. Please do not forget to install HYPERTERM if not installed and check that the path to it is correct in the configuration file.

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.6, produced on 31-JUL-2006.

Changes


  • Support for the terminal_emulator has been dropped. Instead PuTTY terminal is now used as the default terminal emulator.

Bug Fixes


  • SCSI mode sense bugs fixed.
  • DEC3000: VMS 6.2 and 6.1 support added

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.5, produced on 16-JUN-2006.

Bug Fixes

  • Problem with installing VMS 7.1 from CD (NOTIFY ACK log message)
  • Other minor bug fixes 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.4.

Changes

  • The licensing changed. You probably need a dongle update to work with the new version. Contact us for the update.

  • The installation procedure changed
  • Minor bug fixes 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.3.

Bug Fixes

  • Bugcheck in DE500 using sysman on VMS8.x. Now the emulator does not crash. However, sysman raises an error on the network interface because MII is not implemented. The network is operational.
  • Network adaptor naming problem with names like "Realtek #2" is solved.
  • Network mac address for shared mode is now generated automatically from the real address by adding 1 to the two last bytes of the address.
  • The TX device is mapped on a lower slot because it does not work on higher slots. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.2.

Bug Fixes

  • Telnet serial lines did not start the terminal emulator specified by the command option.
  • The tray menu of the emulator Control did not disappear when clicked outside.
  • Cannot open pipe error message.
  • boot_osflags default value was incorrect. 

...

This chapter notes the changes that were made in CHARON-AXP/SMA for Microsoft Windows 1.0.1.

Changes

  • Devices can be loaded in the configuration file
  • The memory size has been made configurable

Bug Fixes

  • Telnet serial lines did not allow reconnection.
  • Telnet serial lines lost symbols on a multi-CPU.

...

Page Properties Report
spaces@all
headingsDocument number, Product, Version, Operating system, Document type, Last update
pageSize100
sortByProduct, Version, Operating system
labeldocchaxpsmav2240w
cqllabel = "docchaxpsmav2240wdocchaxpsmav2303w"