Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: PDF layout corrections

Anchor
TOC
TOC
Include Page
KBCOMMON:KB-CSSstyle
KBCOMMON:KB-CSSstyle

Stromasys  Charon-AXP

Version: 4 5 - Published: 01 Jul  

Table of contents

Table of Contents
excludeTable of contents
stylesquare

Div
classpagebreak


Please review this document before proceeding with the installation of Charon-AXP.

The Release Notes apply to Charon-AXP for Windows version 4.12, up to build 210-1213.

Products included in the Charon-AXP 4.12 for Windows 64-bit

...

1) Charon can be installed and will run, but Microsoft Windows versions are EOL and are not recommended for deployment.

Div
classpagebreak


Hosting hardware requirements and configuration recommendations

...

  • Support for Windows 11, Windows Server 2022

Div
classpagebreak



Problems fixed and other changes

Build 210-

...

13

  • Fix for AXP CPU emulation to avoid CPU halts due to KERNEL STACK NOT VALID exceptions, followed by CPUSANITY or CPUSPINWAIT BUGCHECKs in case of AXP configurations with more than one CPU or more than 4GB of RAM (ID#5836).

Build 210-11

  • Update Stromasys End User License Agreement (EULA) to version issued on 16 February 2024.

Build 210-10

  • Updated End User License Agreement (EULA) EISA configuration table in emulator to eliminate Tru64 UNIX on boot (ID#5844). Relevant for AlphaServer 2000/2100.
  • Product kits now include PCI PassThrough drivers signed by Microsoft (ID#5846). This makes possible use of drivers with Windows 10 and Windows 11 and eliminates signature verification problem when loading the driver. Sample message in case the problem occurs:

    Code Block
    languagetext
    Windows cannot verify the digital signature for the drivers required for this device. 
    A recent hardware or software change might have installed a file that is signed incorrectly or damaged, 
    or that might be malicios software from an unknown source. (Code 52)


  • Fix terminal emulator activation to pass user environment to the process created. In particular, this allows to use Reflection Workspace Terminal Emulator and eliminates Reflection TE startup problem. Sample message in case the proble occurs:

    Code Block
    languagetext
    (X) An application error occured. Please contact Technical Support. 
        Details: 
        Unable to access Micro Focus\Reflection\Desktop\v18.0.


Build 210-12

  • Fix for AXP CPU emulation to avoid CPU halts due to KERNEL STACK NOT VALID exceptions, followed by CPUSANITY or CPUSPINWAIT BUGCHECKs in case of AXP configurations with more than one CPU or more than 4GB of RAM (ID#5836).

Build 210-11

  • Update Stromasys End User License Agreement (EULA) to version issued on 16 February 2024.

Build 210-10

  • Updated End User License Agreement (EULA) text.

Build 210-08

  • Fix emulation of DIGI AccelePort multiplexors and host PCI bridges of various AXP chipsets so that DIGIDRIVER_7 can correctly recognize and initialize the PBXDA board running on OpenVMS 7.1 (ID#5787).
  • Fix Network Control Center (NCC, NetDiag utility) to correctly obtain names of host network interfaces. The problem was observed on Windows 10 (ID#5789).

...

  • New End User License Agreement (EULA) text (ID#5782).
Div
classpagebreak


Build 210-05

  • Add logging an error message indicating syntax error in storage container specification. Previously, such errors were quietly igored or the affected devices were set to offline (ID#5766).
  • Cosmetic change to Charon Installation Utility (InstallShell) to correct message text: display Pre-4.8 version is installed instead of Old version is installed (ID#5768).

  • Wrong version (6.80) of Microsoft NETVMINI driver was included in product kits (ID#5769, IE#5771). Replaced with version 6.30. Fixed product packaging.

  • Fix EW network boot (MOP) of virtual AlphaServer 800 (ID#5773).

...