Anchor | ||||
---|---|---|---|---|
|
Include Page | ||||
---|---|---|---|---|
|
...
Parameter license_key_id
Optional parameter for HASP licenses, mandatory for VE licenses.
Insert excerpt Initial Emulator License Configuration Initial Emulator License Configuration name MutuallyExclusive nopanel true
Parameter Use for HASP Licenses
There can be several license_key_id parameters in this section. They define a prioritized list of license keys. The first entry has the highest priority. If no key with this ID is available, the next key in the list will be tried. If a higher priority key becomes available, the emulator will switch to this license at the next periodic license check.
Syntax:
license_key_id "key-id-prio1"
...
Optional parameter for HASP licensing. There can be several license_id parameters in this section. They define a prioritized list of product license IDs. The first entry has the highest priority. If no key with this product license ID is available, the next product license ID in the list will be attempted. If a higher priority license becomes available, the emulator will switch to this license at the next periodic license check.
Syntax:
license_id "lic-id-prio1"
...
Default: the check is enabled.
...
Parameters system.stop_on_halt and system.stop_on_halt
...
_timeout
These parameters are applicable to emulated systems in which a HP-UX guest operating system runs.
When HP-UX is shut down with the shutdown -h
command, the guest system will be halted. By default, the emulated system will be powered off automatically when a halt is detected (that is, the Charon-PAR process will be stopped). The stop_on_halt parameter allows the user
Depending on the Charon-PAR version one of the following two parameters can be used to influence this behavior.
Syntax:
Charon-PAR Versions 3.0.5 to 3.0.12 (system.stop_on_halt
...
Parameters:
)
The system.stop_on_halt parameter has the following syntax:
Syntax:
system.stop_on_halt = false | true
Parameters:
If set to false, Charon-PAR will not stop the emulated system automatically after the guest operating system has been halted. The emulator must be stopped from the Charon-PAR console (at the pa9-64> or pa9-32> prompt).
Default: true. the emulated system will be stopped automatically after the : true. the emulated system will be stopped automatically after the HP-UX guest operating system has been halted.
Div | ||
---|---|---|
| ||
Charon-PAR Versions 3.0.13 and Higher (system.stop_on_halt_timeout)
The system.stop_on_halt_timeout parameter has the following syntax:
Syntax:
system.stop_on_halt_timeout = <number-of-seconds>
Parameter:
If number-of-seconds is set to 0, Charon-PAR will not stop the emulated system automatically after the HP-UX guest operating system has been halted. The emulator must be stopped from the Charon-PAR console (at the pa9-64> or pa9-32> prompt).
If number-of-seconds is set to a value higher than 0, Charon-PAR will stop the emulated system automatically after the HP-UX guest operating system has been halted .
...
using a timeout corresponding to the specified number of seconds.
This parameter has no default value. To restore the default behavior of the system, comment out or remove the parameter from the emulator configuration file.
Parameter system.do_affinity
...
Every bit in the calculated affinity mask corresponds to one host CPU (counting from 0). For example: 00000001 corresponds to to CPU 0, 00000003 corresponds to CPU 0 and 1.
If the automatically calculated affinity is not sufficient, an alternative would be to start The CPUs that can be used by the emulator can be limited by starting the emulator with an explicit affinity mask defined by the taskset command.
Example: # taskset 2f /opt/charon/bin/charon-par -f myconfigfile.cfg
This would set the affinity mask such that the emulator would only use CPUs 0-3 and 5. If do_affinity is enabled, the automatic calculation will be restricted to the CPUs allowed by the taskset command.
Include Page | ||||
---|---|---|---|---|
|