Each Charon emulator product requires a valid license to run. To access the license, the emulator needs the Sentinel runtime software. This software is part of the Charon-HPA PAR for Linux installation kits. Refer to the software installation section for software installation instructions.
Charon-HPA version 2Please note: Charon-PAR version 3.0.0 and higher is incompatible with licences licenses of earlier versions. Earlier product versions are incompatible with licenses for Charon-HPA 2PAR 3.0.0 and higher. Charon-PAR licenses with version 2.1.0 are not compatible with emulators running Charon-PAR version 2.0.0
If you have a hardware USB license dongle, simply connect it to the system after the Charon-HPA PAR software has been installed and verify that the license can be read correctly by entering the following command:
$ /opt/charon/bin/hasp_srm_view -all |
Please Please note that this the above command must be run from a local connection. If you are connected over a remote connection (e.g., ssh), you will receive an error. As a workaround, you can display the license contents with the following command (adapt the path of the command if your installation location is different):
...
Verify that the license contains the correct product, the correct number of emulator instances, and the correct expiration date (if applicable).
Example of a HP9000 Charon-PAR/PA9-64 license:
...
|
|
|
Code Block | ||
---|---|---|
| ||
Product License Number: 8700-rp7400-01
Virtual Hardware: PA-RISC
HP/PA Physical Key ID: 123456789
Product Name: 8700-rp7400
Product Code: CHHPPA-20xxx-LI
Major Version: 2
Minor Version: 0
32bit and 64bit OS requirements: 64bit
Host Operating System required: LINUX
CPU's allowed: 8
Maximum virtual memory: 32768MB
License expiration date: 26-Mar-2020
Instances allowed: 5
Feature number: 5
Check interval: 60 minutes
<lines removed> |
...
<lines removed>
<lines removed>
<continued to the right> |
<lines removed> |
If you purchased a software license, or if you need more information about licensing in general and how to handle licenses in Charon-HPA can be found in PAR, please refer to the section License Management Overview for Charon-HPAPAR and in the License Handbook. The license chapter contains important information about security and more complicated use cases (for example, multiple license keys, software licenses, and network licenses).
...