Load network adapter (if required)
If you are configuring a DEQNA, DESQA, DELQA, DEUNA, DELUA, DEMNA, DEBNI or PMADAA adapter, use the "load" command as shown below. CHARON-VAX 3100/96/98 and 4000/106/108 emulations automatically load SGEC (with the name "eza") and therefore no "load" command is required.
Example:load DELQA/DEQNA NIC
Load "packet_port" or "tap_port"
Load "packet_port" or "tap_port" to connect the SGEC, DEQNA, DESQA, DELQA, DEUNA, DELUA, DEMNA, DEBNI or PMADAA adapter to the host hardware network card (or to a virtual network interface).
Example:load packet_port/chnetwrk NDIS interface = "eth0"
Connect the loaded "packet_port" ("tap_port") to the loaded virtual network adapter
Connect the SGEC, DEQNA, DESQA, DELQA, DEUNA, DELUA, DEMNA, DEBNI or PMADAA adapter to the "packet_port" ("tap_port") by setting the interface name.
Example:set NIC interface = NDIS
Network booting is supported with exception of VAX6xxx models.
...
The built-in SGEC controller emulator ("eza") has the following parameters that are specified with the "set" command:
interface
Parameter | interface |
---|---|
Type |
interface
Text String | |
Value | Name of corresponding instance of "packet_port" or "tap_port" component |
---|
station_address
Parameter | station_address | ||
---|---|---|---|
Type | Text String | ||
Value | "station_address" provides the ability to configure the adapter’s permanent address. By default the adapter’s permanent address is read from the host system’s NIC. Set the "station_address" when you need to configure a satellite (remotely booted) system that will run DECnet or when the migrated software uses the permanent address on the network adapter. Format:
or
Example: |
|
rx_fifo_size
Parameter | rx_fifo_size |
---|---|
Type | Numeric |
Value | "rx_fifo_size" sets the receive FIFO size. The value is specified in Kb and by default is pre-calculated from the connected port’s size of receive queue. Typically, you do not need to change the "rx_fifo_size" parameter. It is available for extended tuning and bug hunting purposes. |
Div | ||
---|---|---|
| ||
Example:
|
...
Use the following command to load an instance of DEQNA, DESQA, DELQA, DEUNA and DELUA Ethernet controllers:
|
Example:
load DESQA/DEQNA XQA |
DEQNA, DESQA, DELQA, DEUNA and DELUA offer the following configuration parameters that can be specified with "set" command:
address
Parameter | address |
---|---|
Type | Numeric |
Value |
Numeric
Specifies the CSR address. The address must be a valid QBUS and UNIBUS address in I/O space. Initial value is 017774440 which is the factory setting for DEQNA, DESQA and DELQA Ethernet controllers. Use the address parameter if loading several instances of DEQNA, DESQA, DELQA, DEUNA and DELUA. "address" parameter value must be unique for every instance of DEQNA, DESQA, DELQA, DEUNA and DELUA. Example:
|
interface
Parameter | interface |
---|---|
Type | Text String |
Value | Name of corresponding instance of "packet_port" or "tap_port" component |
station_address
Parameter | station_address | ||
---|---|---|---|
Type | Text String | ||
Value | "station_address" provides the ability to configure the adapter’s permanent address. By default the adapter’s permanent address is read from the host system’s NIC. Set the "station_address" when you need to configure a satellite (remotely booted) system that will run DECnet or when the migrated software uses the permanent address on the network adapter. Format:
or
Example: |
|
rx_fifo_size
Parameter | rx_fifo_size |
---|---|
Type | Numeric |
Value | "rx_fifo_size" sets the receive FIFO size. The value is specified in Kb and by default is pre-calculated from the connected port’s size of receive queue. Typically, you do not need to change the "rx_fifo_size" parameter. It is available for extended tuning and bug hunting purposes. |
Example:
|
...
Use the following command to load an instance of the DEMNA Ethernet controller:
load DEMNA/DEMNA <logical name> |
Example:
load DEMNA/DEMNA EXA |
DEMNA Ethernet Ethernet controller offers the following configuration parameters that can be specified with "set" commandcommand:
...
...
Type
...
Value
xmi_node_id
Parameter | xmi_node_id |
---|---|
Type | Number |
Value | Specifies the XMI slot in which the virtual DEMNA controller is placed. For CHARON-VAX/66X0 a free slot between 10 (A) and 14 (E) must be chosen. |
interface
Parameter | interface |
---|---|
Type | Text String |
Value | Name of corresponding instance of "packet_port" or "tap_port" component |
station_address
Parameter | station_address | ||
---|---|---|---|
Type | Text String | ||
Value | "station_address" provides the ability to configure the adapter’s permanent address. By default the adapter’s permanent address is read from the host system’s NIC. Set the "station_address" when you need to configure a satellite (remotely booted) system which will run DECnet or when the migrated software uses the permanent address on the network adapter. Format:
or
Example: |
|
rx_fifo_size
Parameter | rx_fifo_size |
---|---|
Type | Numeric |
Value | "rx_fifo_size" sets the receive FIFO size. The value is specified in Kb and by default is pre-calculated from the connected port’s size of receive queue. Typically, you do not need to change the "rx_fifo_size" parameter. It is available for extended tuning and bug hunting purposes. |
Div | ||
---|---|---|
| ||
Example:
|
...
Use the following command to load an instance of the DEBNI Ethernet controller:
load DEBNI/DEMNA <logical name> |
Example:
load DEBNI/DEMNA EXA |
DEBNI Ethernet controller offers the following configuration parameters that can be specified with "set" command:
...
Parameter
...
Type
...
Value
vax_bi_node_id
Parameter | vax_bi_node_id |
---|---|
Type | Number |
Value | Specifies the VAXBI slot in which the virtual DEBNI controller is placed. |
interface
Parameter | interface |
---|---|
Type | Text String |
Value | Name of corresponding instance of "packet_port" or "tap_port" component |
station_address
Parameter | station_address | ||
---|---|---|---|
Type | Text String | ||
Value | "station_address" provides the ability to configure the adapter’s permanent address. By default the adapter’s permanent address is read from the host system’s NIC. Set the "station_address" when you need to configure a satellite (remotely booted) system which will run DECnet or when the migrated software uses the permanent address on the network adapter. Format:
or
Example: |
|
rx_fifo_size
Parameter | rx_fifo_size |
---|---|
Type | Numeric |
Value | "rx_fifo_size" sets the receive FIFO size. The value is specified in Kb and by default is pre-calculated from the connected port’s size of receive queue. Typically, you do not need to change the "rx_fifo_size" parameter. It is available for extended tuning and bug hunting purposes. |
Example:
|
|
...
Use the following command to load an instance of a PMAD-AA Ethernet controller:
load PMADAA/PMADAA <logical name> |
Example:
load PMADAA/PMADAA EXA |
PMAD-AA TurboChannel Ethernet controller offers the following configuration parameters that can be specified with "set" command:
interface
Parameter | interface |
---|---|
Type |
Value
interface
Text String | |
Value | Name of corresponding instance of "packet_port" or "tap_port" component |
---|
station_address
Parameter | station_address | ||
---|---|---|---|
Type | Text String | ||
Value | "station_address" provides the ability to configure the adapter’s permanent address. By default the adapter’s permanent address is read from the host system’s NIC. Set the "station_address" when you need to configure a satellite (remotely booted) system which will run DECnet or when the migrated software uses the permanent address on the network adapter. Format:
or
Example: |
|
rx_fifo_size
Parameter | rx_fifo_size |
---|---|
Type | Numeric |
Value | "rx_fifo_size" sets the receive FIFO size. The value is specified in Kb and by default is pre-calculated from the connected port’s size of receive queue. Typically, you do not need to change the "rx_fifo_size" parameter. It is available for extended tuning and bug hunting purposes. |
Example:
|
...
...
To create instances of "packet_port", use the “load” command in the configuration file as follows:
load packet_port/chnetwrk <instance-name> |
Example:
load packet_port/chnetwrk pp_1 |
"packet_port" offers several configuration parameters controlling its behavior.
interface
Parameter | interface |
---|---|
Type |
Value
Text string | |||
Value | This parameter Identifies an Ethernet adapter of the host system dedicated to CHARON-VAX. Syntax:
Example:
|
port_enable_mac_addr_change
Boolean
Parameter | port_enable_mac_addr_change | |
---|---|---|
Type | Boolean | |
Value | If "true" is specified, CHARON sets the appropriate Ethernet address automatically. If "false" is specified, set the Ethernet address manually. The default value is "true". Example:
|
port_retry_on_tx
Parameter | port_retry_on_tx | |
---|---|---|
Type | Numeric | |
Value | The "port_retry_on_tx" parameter controls the number of times the port will attempt to transmit the packet before giving up. By default, the value is 3. Increasing this value may introduce problems in carrier loosing logic because not all NIC drivers support carrier status query. Typically, you do not need to increase the value. Example:
|
port_pending_rx_number
Parameter | port_pending_rx_number | |
---|---|---|
Type | Numeric | |
Value | "port_pending_rx_number" parameter sets the number of pending receive buffers. The default value is 63. The maximum value allowed is 195. You may want to increase the "port_pending_rx_number" when you have very busy networking and experience problems like losing connections not related to the carrier loss. Typically, you do not need to change this parameter. Example:
|
port_pending_tx_number
Parameter | port_pending_tx_number | |
---|---|---|
Type | Numeric | |
Value | "port_pending_tx_number" parameter sets the number of buffers the port uses to transmit. The default value is 62. You may want to increase the "port_pending_tx_number" value if the log file indicates dropped TX packets due to TX queue overflow. Typically, you do not need to change this parameter. Example:
|
.
log
Parameter | log | ||||
---|---|---|---|---|---|
Type | Text string | ||||
Value | If this parameter is set to some valid file name or a directory where the log files for each individual session will be stored CHARON logs Recv and Xmit packets at the emulated port layer. If an existing directory is specified, CHARON automatically enables creation of individual log files, one for each session using the same scheme as used for the generation of the rotating log files. If the "log" parameter is omitted, CHARON does not create log. In certain situations enabling this parameter may help to detect loss of packets. Example:
|
Div | ||
---|---|---|
| ||
Info |
---|
"tap_port" parameters are the same as "packet_port" ones |
Example:
|
...
During DECnet OSI installation or DECnet OSI interface reconfiguration, DEQNA and DESQA models are not recognized as valid devices. (DECnet OSI SPD).
Info |
---|
The integrated SGEC Ethernet "EZA" on MicroVAX 3100 & VAX 4000-106/108 is supported by DECnet OSI. The integrated ESA (AMD Lance 7990) device is not currently implemented in Charon-VAX. |
...