Syntax for loading PBXDA-xx PCI serial adapter:
load digi <name> |
Example:
load digi SERIAL_A |
Note | |
---|---|
In AlphaStation 400 configuration use the following syntax for PBXDA-xx PCI serial adapter loading:
|
By default PBXDA-xx adapter uses first available PCI slot. If instead some particular slot is needed, refer to this section for details of specific placement of PCI peripherals on CHARON-AXP PCI bus.
Div | ||
---|---|---|
| ||
|
Configuration parameters
The PBXDA-xx PCI serial adapter emulation has only one configuration parameter:
host_bus_location
Parameter |
---|
...
...
Value
host_bus_location | |||||||||||
Type | Text String | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Value | Establish connection between virtual PBXDA-xx PCI serial adapter and physical DIGI AccelePort PCI serial adapter installed on CHARON-AXP host (pass through mode) Syntax:
where:
Example:
|
Installation of
...
DIGI AccelePort PCI serial adapter
- Install the PBXDA-xx PCI serial adapter (see below for a list of supported models) DIGI AccelePort PCI serial adapter to some spare PCI slot of the host system
- Boot a Windows operating system
- Open “Computer Management”
- Select “Device Manager”
- In the right window select the desired physical serial adapter connected to the system, right-click the mouse button, and the corresponding menu will appear.
- From the menu select “Update driver…”. Windows will show “Hardware Upgrade Wizard”
- Select “No, not this time”, click “Next”
- Select “Install from a list or specific location (Advanced)”, click “Next”
- Select “Don’t search. I will choose the driver to install”, click “Next”
- Click “Have Disk…”. Windows shows dialog “Install From Disk”
- Instead of “A:\”, click “Browse” and select path to the folder in which driver’s INF file is located (typically "C:\Program Files\CHARON\Drivers\PBXDA-xxDIGI_X.X.0.XXXXX"), select “PBXDA-xx“digi_ppt_amd64.inf”, and click “Open”
- The “Hardware Upgrade Wizard” should have “CHARON PBXDA-xx serial DIGI adapter”. Select it, and click “Next”
- There will be one or two more dialogs, but they are usual for device driver installation.
- Reboot the host
...
Div | ||
---|---|---|
| ||
|
Mapping to
...
host DIGI AccelePort PCI serial adapter
Open “Computer Management” application and select “Device Manager”:
On
Div | ||
---|---|---|
| ||
|
In the right panel select the installed PBXDA-xx PCI serial adapter:proper physical DIGI adapter:
Div | ||
---|---|---|
| ||
|
Open its property properties sheet by double-click clicking on the selected adapter:
The “Location:” on the above picture gives X, Y, and Z for the "host_bus_location" parameter, for example:
|
Non-US-EN installations of Windows may present “Location:” string in local language, but "host_bus_location" parameter requires English notation, so the words “PCI”, “bus”, “device”, and “function” must be specified in English.
...