load ndis5_chpack_port/chnetwrk EWA0 interface="..."

and

load ndis6_chpack_port/chnetwrk EWA0 interface="..."

can be replaced with:

load packet_port/chnetwrk EWA0 interface="..."

  • For the emulated network adapters the communication speed and mode is recommended to be commented out (set to automatic). If it is necessary, see the example below:

load DE500BA/dec21x4x EWA interface=EWA0
load packet_port/chnetwrk EWA0 interface="..."
set EWA adapter_mode="100BaseT-FD"

  • On VMware, legacy_mode should be set in the Charon configuration for emulated AXP network adapters if Promiscuous mode cannot be set (this solution does not work in multi-instance configurations).

  • The console definition syntax has been changed in the configuration file starting with v4.9. Please read the User's Guide for instructions on how to apply it if you currently use a Charon version prior to v4.9.

  • If "IDLE" utility is going to be used, perform the following commands after its installation:

$ @sys$startup:charoncp_startup $ charoncp set idle /enable

  • refer to the user's guide for further information.

Notes related to upgrade from previous version

...

  • Charon-AXP does not emulate the LSI 53C810 SCSI controller. Charon-AXP emulates the Qlogic KZPBA SCSI controller, which is the reason for the earliest supported VMS version to be 6.2-1H3, earliest supported Tru64 version to be 3.2. (ID#2291).

  • If the driver for KZPBA is installed on an earlier version of VMS or Tru64 before system transfer to Charon-AXP, it will function on Charon-AXP.

  • The OPA0 console of the Charon service does not appear if a non "Administrator" user starts the service (ID#3209).

  • DS20 initialization might take a long time on Windows Server 2008 R2 (ID#3194).

  • Digital UNIX 4.0g fails to install on AS4100 if FC is configured. Specific Tru64 patches and firmware versions might be required. SAN device should be set to SCSI-2 mode (ID#3191).

  • The DE500BA device error count after boot is not 0 on OpenVMS 8.2/8.3 (ID#2963). There are no negative side effects.

  • Direct SCSI access only supports Windows SCSI devices which use a SCSIport driver. These include most of the device drivers on Windows XP and Windows Server 2003 (R2), but does not work on Windows 7 and Server 2008 (R2). If SCSIport is not supported (and Storport method is used instead), direct SCSI access cannot be used.
    This is most likely to be the case for Windows 7 and Windows Server 2008 (R2) platformsto SCSI devices is not supported. Consider use of Charon-VAX for Linux instead, or call Stromasys for possible alternatives.
  • Performance tests could hang VMS 6.2-1H3 on an emulated AS400.

  • Charon-AXP does not emulate VGA adapters, thus OPA0 is always a system console. Applications hard-coded to use OPA0 and TTA0 as their own interfaces may not function correctly.

  • Network speed auto negotiation works with some restrictions (see the table below). It is always recommended to use full duplex mode on the hosting server.

...

  • A "CRC error" appears when running "$ BACKUP/LIST/REW MKA100:..." on OpenVMS Alpha Version 8.4 (ID#2925).

  • Due to the change of "Charon Virtual Machines Manager" to "Charon Virtual Machine Manager", an upgrade from a version prior to 4.11 will create a new shortcut on the desktop and will not remove the one pointing to "Charon Virtual Machines Manager". This then has to be done manually. Please note that both shortcuts point to the same executable file.

New functionality introduced in previous versions

...

Child pages (Children Display)
pageCharon-AXP V4.12 for Windows - Release Notes
first2


Include Page
KBCOMMON:DOC-GoToToc