Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: AXP/VAX information

...

Code Block
languagetext
20211213:120216.970965:Trying to login to license server: 127.0.0.1
20211213:120219.975731:License allowed CPUs: 8.
20211213:120219.975746:License allowed memory size: 32768.
20211213:120219.979873:Connected with license server: 127.0.0.1
20211213:120219.979900:Found available license ID: 03.00000003.002.006.
20211213:120219.979908:Customer name: Stromasys
20211213:120219.979915:Grace period is 120 minutes.
20211213:120219.979928:Virtual hardware model Charon-PA9-64-L4 is licensed.
20211213:120219.979937:Maximum concurrent instances are limited to 10.
20211213:120219.979950:Maximum allowed virtual CPU(s) are 8.
20211213:120219.979959:Maximum allowed virtualized memory is 32768 MB.
20211213:120219.979967:Major allowed version number is 3.
20211213:120219.979976:Minor allowed version number is 0.
20211213:120219.979988:Expiration UTC time: 2022-06-08 23:55:00.
20211213:120219.980216:Product Name = Charon-PA9-64-L4 License key ID = 03.00000003.002.006.

Charon-AXP/VAX Emulator Log Files

The default location for the Charon-AXP/VAX emulator log files on Linux (Linux is required for VE licensing): if the setting of the template configuration is used, the default is the directory from which the emulator instance was started.

The name and location can be influenced via the configuration file.

By default log file name is <model-name>.log.

Div
classpagebreak


License server not found at start:

...