Set unique ID for SHAC controller of each node
Configuration IDs of SHAC is set using console (and stored in ROM file, so make sure the ROM file is specified in configuration file) in the following way:
>>>sho dssi_id
DSSI_ID Bus 0/A = 1
DSSI_ID Bus 1/B = 1
>>>set dssi_id 0 2
>>>set dssi_id 1 2
Description Note that value of "dssi_id" must be unique for each SHAC instances and HSD50 controllers must not use them; for example if 0 and 1 is used as SHAC ID of different VAX nodes the HDS50 controller instance cannot use ID 0 and 1. .
Configure preloaded SHAC adapters PAA
Configuration Div class small set PAA port[<ID of the node to connect to>]=<port to receive connection from the node specified by ID> host[<ID of the node to connect to>]="<connected node host>:<connected node port>"
Example:
set PAA port[2]=11012 host[2]="pollux:11021"
In this example a VAX node SHAC adapter connects to a node "pollux" (having ID=2) to its port 11021 and expects connection from it on the port 11012.
Description The second step is to interconnect SHAC adapters of different nodes.
Use ID of the nodes as a reference for interconnections as it is shown in the example at left.
Detailed meaning of the parameters is explained in "Example 1" section below
.
Load HSD50 adapter
Configuration load HSD50 <instance name> dssi_host=<SHAC instance> dssi_node_id=<HSD50 node ID>
Example:
load HSD50 DISKS dssi_host=PAA dssi_node_id=3
In this example HSD50 controller instance "DISKS" is loaded, connected to "PAA" SHAC controller and assigned with ID 3.
Description Load HSD50 instance, assign ID for it and connect it to "PAA" SHAC adapter.
For each member of cluster an identical definition of HSD50 controllers must be loaded. It is convenient to introduce a specific include configuration file containing the same configuration commands as it is shown in "Example 2" section below.
Note that <HSD50 node ID> parameter must be unique for each SHAC and HSD50 instances; for example if 0 and 1 are used as IDs for nodes (see the Step 1) the HDS50 instance cannot use 0 or 1, but it can be set to 3, for example.
.
Set SCS system ID and allocation class
Configuration set
<HSD50
instance
name>
scs_system_id=<SCS
ID>
mscp_allocation_class=<allocation
class>
Example:
set
DISKS
scs_system_id=3238746238
mscp_allocation_class=1
In this example HSD50 instance "DISKS" (configured at the previous step) is assigned with SCS ID "3238746238" and MSCP allocation class 1.
Description Set SCS system ID and the MSCP allocation class.
These setting must be the same for all HSD50 controllers loaded!
Warning Note that the MSCP allocation class must be different from the allocation class of the VAX node (excuding some special cases when they can be the same - please refer to OpenVMS Guides on Clusters configuration for more details).
For nodes it is set using MODPARAMS.DAT and AUTOGEN
Refer to OpenVMS User's Guides for details
.
Configure mapping to the system resources
Configuration set <HSD50 instance name> container[<unit number>] = <mapping>
Example:
set DISKS container[0]="/mnt/share/dua0-rz24-vms-v6.2.vdisk"
In this example the Unit 0 of the HSD50 controller instance "DISKS" is mapped to some disk image, located in some shared directory on disk server.
Description The final step is specifying HSD50 mapping to the system resources.
Since the disks should be distributed between different VAX nodes they should be located as disk images on some shared space or - alternatively - CHARON host should use such mechanism as iSCSI to address the common disks on some disk storage.
See the sections below for different examples of the mapping
...
IDs of SHAC is set using console (and stored in ROM file, so make sure the ROM file is specified in configuration file) in the following way:
|
...
set PAA port[<ID of the node to connect to>]=<port to receive connection from the node specified by ID> host[<ID of the node to connect to>]="<connected node host>:<connected node port>" |
Example:
set PAA port[2]=11012 host[2]="pollux:11021" |
In this example a VAX node SHAC adapter connects to a node "pollux" (having ID=2) to its port 11021 and expects connection from it on the port 11012.
...
The second step is to interconnect SHAC adapters of different nodes.
Use ID of the nodes as a reference for interconnections as it is shown in the example at left.
Detailed meaning of the parameters is explained in "Example 1" section below
...
load HSD50 <instance name> dssi_host=<SHAC instance> dssi_node_id=<HSD50 node ID> |
Example:
load HSD50 DISKS dssi_host=PAA dssi_node_id=3 |
In this example HSD50 controller instance "DISKS" is loaded, connected to "PAA" SHAC controller and assigned with ID 3.
...
Load HSD50 instance, assign ID for it and connect it to "PAA" SHAC adapter.
For each member of cluster an identical definition of HSD50 controllers must be loaded. It is convenient to introduce a specific include configuration file containing the same configuration commands as it is shown in "Example 2" section below.
Note that <HSD50 node ID> parameter must be unique for each SHAC and HSD50 instances; for example if 0 and 1 are used as IDs for nodes (see the Step 1) the HDS50 instance cannot use 0 or 1, but it can be set to 3, for example.
...
set <HSD50 instance name> scs_system_id=<SCS ID> mscp_allocation_class=<allocation class> |
Example:
set DISKS scs_system_id=3238746238 mscp_allocation_class=1 |
In this example HSD50 instance "DISKS" (configured at the previous step) is assigned with SCS ID "3238746238" and MSCP allocation class 1.
...
Set SCS system ID and the MSCP allocation class.
These setting must be the same for all HSD50 controllers loaded!
Warning |
---|
Note that the MSCP allocation class must be different from the allocation class of the VAX node (excuding some special cases when they can be the same - please refer to OpenVMS Guides on Clusters configuration for more details). For nodes it is set using MODPARAMS.DAT and AUTOGEN Refer to OpenVMS User's Guides for details |
...
set <HSD50 instance name> container[<unit number>] = <mapping> |
Example:
set DISKS container[0]="/mnt/share/dua0-rz24-vms-v6.2.vdisk" |
In this example the Unit 0 of the HSD50 controller instance "DISKS" is mapped to some disk image, located in some shared directory on disk server.
The final step is specifying HSD50 mapping to the system resources.
Since the disks should be distributed between different VAX nodes they should be located as disk images on some shared space or - alternatively - CHARON host should use such mechanism as iSCSI to address the common disks on some disk storage.
...
Warning |
---|
It is advisable to start any field test with implementing the cluster examples provided below |
...