The LPV11 (being a CHAPI component) provides the following configuration parameters, to be specified using the "set" command:
address
Parameter | address | |
---|---|---|
TypeDescription | Numericaddress | |
Value | Numeric | Specifies the CSR address. This address must be a valid QBUS 22-bit address in an I/O space. The initial value is 017777514, which is the factory setting for an LPV11. |
vector
Parameter | vector |
---|---|
Type | Numeric |
Value | Specifies the interrupt vector. The initial value is 0200, which is the factory setting for an LPV11. |
parameters
Parameter | parameters | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Type | Text String | |||||||||||||||||||||
Value | Specifies the name of the file in which the LPV11 prints the text, the name of a physical printer or a TCPIP port to connect to an external utility, like HOSTPrint, (along with some additional parameters):
|
It’s possible to load as many LPV11 devices as you wish and the system running on the emulated VAX/PDP-11 allows this to be done. To load LPV11 devices use the standard QBUS parameters: "address" and "vector" to select the correct place on the QBUS.
...