Anchor | ||||
---|---|---|---|---|
|
Include Page | ||||
---|---|---|---|---|
|
...
Option | Description | |||||||
---|---|---|---|---|---|---|---|---|
physical_serial_line | Mapping to host "\\.\COM<n>" ("COM<n>:") physical serial line. | |||||||
virtual_serial_line | Mapping to an IP port of CHARON host.
Example:
In the example above, the CHARON VM use uses the IP port "10003" for the HP Alpha console and starts the "Putty" terminal emulator (included in each the CHARON distributiveinstallation kit) with the "OPA0" saved session directing it to connect to the IP port "10003". If the terminal emulator is closed, it is always possible to reopen it with the "Show Console" feature from the CHARON Virtual Machines Manager. |
Status | ||||
---|---|---|---|---|
|
The default setting is "load virtual_serial_line/chserial OPA0 port=10003 application="putty.exe -load OPA0".:
The second console line "TTA0" can be also optionally configured (for 1 CPU models such as HP AlphaServer 400, HP AlphaServer 800, HP AlphaServer 1000, HP AlphaServer 1000A, HP AlphaServer DS10, HP AlphaServer DS10L and HP AlphaServer DS15):
...
Follow this link for details on the KZPBA controllers configuration.
Back to Table of Contents
KGPSA-CA PCI FC disk controller
...
Follow this link for details on the KGPSA-CA controllers configuration.
Back to Table of Contents
KGPSA-CA mapping to the host resources
...
The numbers in the square brackets represent the KGPSA-CA units. They can be in the range of 0 to 32766 but no more than 255 units can be configured on a single controller.
Back to Table of Contents
KGPSA-CA mapping to a storage controller using its "presentation" mode
...
Type of mapping | Description |
---|---|
storage_controller_path_id = <Storage controller path ID> | "Storage controller path ID" is a storage (for example SAN) controller path ID. This ID can be obtained from the special utility "Device check tool" (accessible in the "Host Information and Utilities" section of the CHARON Virtual Machines Manager). Once specified, all the disks attached to the storage are automatically mapped as disk units to the CHARON VM. |
Back to Table of Contents
KGPSA-CA pass through mode
...
Supported | Not Supported | Not tested |
---|---|---|
LP8000 | LPe1150 (FC2142SR, A8002A) | LPe11000 |
Back to Table of Contents
Div | ||
---|---|---|
| ||
FDDI support via DEFPA PCI FDDI controller in "pass through" mode
...
Non-US-EN installations of Windows may present “Location:” string in local language, but "host_bus_location" parameter requires English notation, so the words “PCI”, “bus”, “device”, and “function” must be specified in English.
Back to Table of Contents
Div | ||
---|---|---|
| ||
Serial lines support via emulated PBXDA-xx family PCI controllers in "pass through" mode
...