Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: layout reviewed / PDF export

Anchor
TopConfigurationPage
TopConfigurationPage
Include Page
KBCOMMON:KB-CSSstyle
KBCOMMON:KB-CSSstyle

...

set toy container="clipper.dat"

...

...


The ROM container stores an intermediate state of the Flash ROM and some console parameters. It is highly recommended to define and activate this container:

set rom container="clipper.bin"


Div
classpagebreak

Back to Table of Contents

...

#load physical_serial_line OPA0 line="COM1:"
#load virtual_serial_line OPA0 port=10003
#load virtual_serial_line OPA0 port=10003 application="opa0.ht"
load virtual_serial_line OPA0 port=10003 application="putty -load OPA0"
#load virtual_serial_line OPA0 port=10003 application="c:\kea\user\opa0.ktc"

The goal of this configuration step is to tell the CHARON VM what host device to use as the virtual system console. The following options are available:

...

Additionally it is possible to specify a parameter "media_type" to assign the type of the attached media explicitly.

...

Example:

set PKA media_type[600]="RX23"

...

Follow this link for details on the KZPBA controllers configuration.

Back to Table of Contents

KGPSA-CA PCI FC disk controller

...

Follow this link for details on the KGPSA-CA controllers configuration.

Back to Table of Contents

KGPSA-CA mapping to the host resources

...

The numbers in the square brackets represent the KGPSA-CA units. They can be in the range of 0 to 32766 but no more than 255 units can be configured on a single controller.

Back to Table of Contents

Div
classpagebreak

KGPSA-CA mapping to a storage controller using its "presentation" mode

...

load KGPSA FGA storage_controller_path_id = 5008-05F3-0005-2950-5008-05F3-0005-2951

...

This line loads an instance of KGPSA-CA controller and maps it to some external controller having ID "5008-05F3-0005-2950-5008-05F3-0005-2951".

Type of mappingDescription
storage_controller_path_id = <Storage controller path ID>

"Storage controller path ID" is a storage (for example SAN) controller path ID.

This ID can be obtained from the special utility "Device check tool" (accessible in the "Host Information and Utilities" section of the CHARON Virtual Machines Manager). Once specified, all the disks attached to the storage are automatically mapped as disk units to the CHARON VM.

Back to Table of Contents

Div
classpagebreak

KGPSA-CA pass through mode

...

SupportedNot SupportedNot tested

LP8000
LP9000
LP9002
LP9802
LP10000
LP10000DC
LP10000-S
LPX1000
LP11002
LPe11002 (FC2242SR, A8003A)
LPe1105

LPe1150 (FC2142SR, A8002A)LPe11000

Back to Table of Contents

Div
classpagebreak


FDDI support via DEFPA PCI FDDI controller in "pass through" mode

...

(warning) Non-US-EN installations of Windows may present “Location:” string in local language, but "host_bus_location" parameter requires English notation, so the words “PCI”, “bus”, “device”, and “function” must be specified in English.

Back to Table of Contents

Div
classpagebreak


Serial lines support via emulated PBXDA-xx family PCI controllers in "pass through" mode

...