TopConfigurationPage

...

You can optionally uncomment this line to differentiate this CHARON-AXP instance from all others in a multi-instance environment. The configuration name can be any label that is meaningful.

It is possible to specify a configuration name containing spaces, in this case use quotation marks:

set session configuration_name = "My ES40"

The configuration name is reported in the log file and is used to set the log file name for rotating log (see further: Rotating log (default) ).

...

(warning) Note that the number of the specified host CPUs must correspond to the number of the emulated CPUs (one host CPU for one emulated CPU). This ; this value is specific for each HP Alpha model) and number of CPUs needed for CHARON application itself ("n_of_io_cpus").

Back to Table of Contents

...

(warning) Note that the number of the specified CPUs dedicated to CHARON I/O operations must correspond to the total number of available for CHARON CPUs (restricted by "affinity" parameter if needed) and the number of the virtual HP Alpha CPUs to be emulated.

...

OptionDescription
physical_serial_lineMapping to host "\\.\COM<n>" ("COM<n>:") physical serial line.
virtual_serial_line

Mapping to an IP port of CHARON-AXP host.
Using this mapping it is possible to connect to CHARON-AXP console and disconnect from it at any time.It is also possible to start up some chosen application to connect to the CHARON console IP port.

ParameterDescription
portSpecifies a unique IP port on the host to which the CHARON-AXP console will be mapped.
applicationA string specifying a name of an application to be started together with CHARON to provide emulation of HP Alpha console (terminal emulator)It is assumed that this application has already been configured to use the IP port specified by the corresponding "port" parameter

Example:

load virtual_serial_line/chserial OPA0 port=10003 application="putty.exe -load OPA0"

In the example above, CHARON-AXP use the IP port "10003" for the HP Alpha console and starts the "Putty" terminal emulator (included in each CHARON distributive) with the "OPA0" saved session directing it to connect to the IP port "10003". If the terminal emulator is closed, it is always possible to reopen it with the "Show Console" command from the CHARON system tray icon:

...

Type of mappingDescription
"<file-name>.vdisk"

Mapping to the file representing a physical disk of the HP Alpha system (disk image). 
These files can be created from scratch with "MkDisk" utility. Data and OS disks backups are transferred from the original system via tapes or network and restored into these container files. 
Mapping may also include the full path (recommended), for example: "C:\My disks\my_boot_disk.vdisk" 

"\\.\PhysicalDriveNPhysicalDrive<N>"

Mapping to physical disk. (warning) Be careful not to destroy all the information from the disk dedicated to CHARON-AXP by mistake.

These disks must not be formatted by the host OS.

"\\.\PhysicalDrive(DevID =XXX-XXXX-XXXX-XXXX-XXXX-XXXX-XXXX-XXXX)"

Mapping to physical disk by its WWID. (warning) Be careful not to destroy all the information from the disk dedicated to CHARON-AXP by mistake.

These disks must not be formatted by the host OS.

DevID addresses the target physical disk by its WWID (hexadecimal 128-bit identifier assigned to the disk drive by its manufacturer/originator).

Example:

set PKA container[100]=”\\.\PhysicalDrive(DevID= 6008-05F3-0005-2950-BF8E-0B86-A0C7-0001)”
"\\.\PhysicalDrive(iScsiTarget = <iSCSI target>, LUN = <LUN number>)"

Mapping to iSCSI disks.

ParameterDescription
iScsiTargetAddresses the disk by its iSCSI target name.
LUNSpecifies LUN on connected iSCSI disk. 

Example:

set PKA container[200]=”\\.\PhysicalDrive(iScsiTarget= iqn.2008-04:iscsi.charon-target-test1, LUN= 1)”
"\\.\ScsiNScsi<N>:X<X>:Y<Y>:Z<Z>

Mapping to some SCSI device unknown to Windows for direct mapping, for example, a SCSI disk or tape reader.

The values of N, X, Y and Z can be collected using special utility "Host Device Check" included in the CHARON distributive - or manually by investigation of the devices connected to CHARON host in the "Device Manager" applet.

ParameterDescription
NA logical number assigned by host operating system (Microsoft Windows) to logical or host’s physical storage resource such as physical SCSI HBA
XAn internal SCSI bus number (usually 0) on host’s physical SCSI HBA
YA SCSI ID of physical SCSI target device attached to host’s physical SCSI HBA
ZA logical unit number inside physical SCSI target device attached to host’s physical SCSI HBA


"\\.\CdRomNCdRom<N>"Mapping to CD-ROM device.
"<file-name>.iso"Mapping to an ISO file for reading distribution CD-ROM image.
Mapping may also include the full path (recommended), for example: "C:\My disks\vms_distributive.iso"

"\\.\Tape<N>"

Mapping to a host tape device.
"<file-name>.vtape"Mapping to the file representing the tape (tape image).
These files are created automatically.
Mapping may also include a full path (recommended), for example: "C:\My tapes\backup.vtape"
"\\.\A:"Mapping to Floppy drive.
"\\.\<N>:"Mapping to some other type of drive, for example magneto-optical drive.

...

Follow this link for details of KZPBA controllers configuration.

Back to Table of Contents

KGPSA-CA PCI FC disk controller

...

Follow this link for details of KGPSA-CA controllers configuration.

Back to Table of Contents

KGPSA-CA mapping to the host resources

...

Numbers in the square brackets represent KGPSA-CA units. They can be in the range 0..32766, but no more than 255 units can be configured on a single controller.

Back to Table of Contents

KGPSA-CA mapping to a storage controller using its "presentation" mode

...

This line loads an instance of KGPSA-CA controller and maps it to some extarnal controler having external controller having ID "5008-05F3-0005-2950-5008-05F3-0005-2951".

Type of mappingDescription
storage_controller_path_id = <Storage controller path ID>

"Storage controller path ID" is a storage (for example SAN) controller path ID.

This ID can be obtained from the special utility "Host Device Check". Once specified, all the disks attached to the storage are automatically mapped as disk units to CHARON-AXP.

Back to Table of Contents

KGPSA-CA pass through mode

...

SupportedNot SupportedNot tested

LP8000
LP9000
LP9002
LP9802
LP10000
LP10000DC
LP10000-S
LPX1000
LP11002
LPe11002 (FC2242SR, A8003A)
LPe1105

LPe1150 (FC2142SR, A8002A)LPe11000

Back to Table of Contents

Div
classpagebreak

 

FDDI support via DEFPA PCI FDDI controller in "pass through" mode

...

(warning) Non-US-EN installations of Windows may present “Location:” string in local language, but "host_bus_location" parameter requires English notation, so the words “PCI”, “bus”, “device”, and “function” must be specified in English.

Back to Table of Contents

Div
classpagebreak

 

Serial lines support via emulated PBXDA-xx family PCI controllers in "pass through" mode

...