Info

Starting with ESXi 6.5, it is not possible to select E1000 adapter when a new virtual machine is created using Windows Server 2012, 2016 and Windows 10 templates.

The following workarounds are avaible:

  • Import the virtual machine from an older version of ESXi
  • Do not select "Windows Server 2012", "Windiows Server 2016" or "Windows 10/64bit" during virtual machine creation but select "Windows Server 2008" or "Other/Other 64bit" for example.

...

  1. Ensure your license allows you to upgrade to that version. If not, please generate a C2V file and send it to STROMASYS for update. See CHARON-AXP for Linux utilities - 'hasp_srm_view' utility
  2. Prepare the new kit RPM files as it is described in "471924856Before installation" and "471924856Distribution preparation" sections.
  3. Stop all running CHARON-AXP instances.
  4. Make sure that no template files (i.e. "es40.cfg.template") have been used for your specific configuration otherwise copy those files to a dedicated folder.
  5. Login as "root" user.
  6. Remove the old CHARON-AXP version as described in the "CHARON-AXP for Linux deinstallation" chapter.
  7. Proceed with the instructions on the new kit installation as described in the "471924856Installation" section.
  8. Install the license for the new CHARON-AXP as described in the "471924856License installation" section.

  9. Start all the CHARON-AXP services stopped at step #3.

...