Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Cluster operation requires (virtual) disks that are simultaneously accessible by all CHARON-VAX nodes involved. This can be implemented, for instance, by using a properly configured iSCSI initiator / target structure or a fiber channel storage back-end. Disks on a multiport SCSI switch are not acceptable, as a SCSI switch does not provide true simultaneous access to multiple nodes.

(info) When a tape or disk image, connected to an emulated DSSI controller, is dismounted, in VAX/VMS, it is disconnected from CHARON-VAX and can be manipulated.

Warning

The emulated DSSI subsystem has many configurable parameters when multiple nodes on a single DSSI bus are to be connected. Incorrect configuration, in particular non-identical specification of emulated HSD50 disks in the DSSI nodes, is likely to cause data corruption. It is advisable to start any field test by implementing a single node.

...