Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Page breaks management for PDF export

...

Parameterlog_flush_period
TypeNumeric
Value
  • <period-in-seconds>

Defines a period of flushing log to disk.

Default period is 60 seconds (it means that every minute log file is flushed to disk)

Examples:

set session log_flush_period=30



Div
classpagebreak


license_key_id

Parameter

license_key_id

TypeText string
Value

A set of Sentinel Key IDs that specifies the license keys to be used by CHARON. It is also possibly to use a keyword "any" to force CHARON to look for suitable license in all available keys if the license is not found in the specified keys.

Example:

set session license_key_id = "1877752571,354850588,any"

Based on the presence of this parameter in the configuration file, CHARON behaves as follows:
 

  1. No keys are specified (the parameter is absent)
    CHARON performs an unqualified search for any suitable key in unspecified order. If no key is found, CHARON exits.

  2. One or many keys are specified
    CHARON performs a qualified search for a regular license key in the specified order. If it is not found, CHARON exits (if the keyword "any" is not set).

If the keyword "any" is specified then if no valid license has been found in the keys with specified ID’s all other available keys are examined for valid license as well.

Note

The order in which keys are specified is very important. If a valid license was found in the key which ID was not the first one specified in configuration file, then available keys are periodically rescanned and if the key with the ID earlier in the list than the current one is found CHARON tries to find a valid license there and in case of success switches to that key.

...

...


license_id

Parameter

license_id

TypeText string
Value

A set of license identifiers that specifies the licenses to be used by CHARON. This parameter is applicable only to licenses on which Stromasys placed restrictions on what products can be combined on a single license key. Please contact your Stromasys representative or VAR for more information.

Example:

set session license_id = "2718281828,314159265"

If this parameter is set, Charon considers for validation only the available licenses with license ID parameter set and equal to one of the license ID's specified in the configuration. This prioritized list corresponds to the "Product License Number" line in the Product section of the license.


Div
classpagebreak


license_key_lookup_retry

Parameterlicense_key_lookup_retry
TypeText String
Value

In case the CHARON-VAX license connection is not present at guest statup, this parameter specifies how many times CHARON-VAX will try to reestablish the connection and, optionally, a period of time between retries.

Syntax:

set session license_key_lookup_retry = "N [, T]"

where:

  • N - Number of retries looking for license key (or keys)
  • T - Time between retries in seconds. If not specified 60 seconds is used

Example 1

set session license_key_lookup_retry = 1

If license key is not found during initial scan, do only one more attempt after 60 seconds.

Example 2

set session license_key_lookup_retry = "1,30"

Same as above but retry in 30 seconds.

Example 3

set session license_key_lookup_retry = "3,10"

If license key not found during initial scan, do 3 more attempts waiting 10 seconds between them.

Example 4

set session license_key_lookup_retry = "5"

If license key is not found during initial scan, do 5 more attempts waiting 60 seconds between them.

...