Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

After attaching the virtual disk, as described in Preparing to Install the Guest Utilities, use the POLYCENTER Software Installation (PCSI) utility to install the Bypass Driver.  The following example demonstrates the PCSI PRODUCT INSTALL commands to execute and the expected output (the example assumes the utilities virtual disk image is attached at DKA400:).

Panel
bgColor#ffffff
titleBGColor#f0f0f0
titleBypass Driver Installation

$ PRODUCT INSTALL CHARON_DISK/SOURCE=DKA400:[BYPASS]
%PCSI-I-CANNOTVAL, cannot validate DKA400:[BYPASS]SRI-AXPVMS-CHARON_DISK-V0104--1.PCSI;1
-PCSI-I-NOTSIGNED, product kit is not signed and therefore has no manifest file
 
The following product has been selected:
    SRI AXPVMS CHARON_DISK V1.4 Layered Product
 
Do you want to continue? [YES] YES
 
Configuration phase starting ...
 
You will be asked to choose options, if any, for each selected product and for any products that may be installed to satisfy software dependency requirements.
 
SRI AXPVMS CHARON_DISK V1.4: Charon disk driver V1.4 for OpenVMS Alpha.
 
    Copyright (C) 1976, 2009 Software Resources International
 
    CHARON_DISK was produced by Software Resources International
 
* This product does not have any configuration options.
 
Execution phase starting ...
 
The following product will be installed to destination:
    SRI AXPVMS CHARON_DISK V1.4 DISK$TARDISSYSTEM:[VMS$COMMON.]
 
Portion done: 0%...10%...20%...80%...100%
 
The following product has been installed:
    SRI AXPVMS CHARON_DISK V1.4 Layered Product

...

One of the benefits of the Bypass Driver is that it allows you to specify a storage technology other than SCSI for the controller.  This can be particularly important if an existing native environment has been set up as dependant on a certain type of storage technology.  The table below shows the command necessary to define a storage controller for the supported technologies.  In the configuration command definition, n denotes the number of controllers to create.

Panel
bgColor#ffffff
titleBGColor#f0f0f0
titleBypass Driver Storage Controllers
Control TypeStorage TechnologyConfiguration Commands
PGFibreChannelload n PG bypass 
PIDSSIload n PI bypass
PKSCSIload n PK bypass
PQIDEload n PQ bypass
PRRAIDArrayload n PR bypass
PUMSCPload n PU bypass

...

Configuring a disk device as attached to a bypass enabled controller is no different for SCSI devices.  For other storage technologies only the device class changes, all other object members mentioned in ... are applicable.  The table below lists the disk device class for each storage technology.

Panel
bgColor#ffffff
titleBGColor#f0f0f0
titleBypass Disk Device Classes
Device ClassStorage TechnologyExample load Command
DGFibreChannelload DGA500
DIDSSIload DIA0
DKSCSIload DKA400
DQIDEload DQA0
DRRAIDArrayload DRA0
DUMCSPload DUA0:

...