Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Reverted from v. 2

...

  1. Loading virtual serial lines controller, for example:

    load DHV11/DHV11 TXA

    In this example, an instance of a "DHV11" serial line controller is loaded and named "TXA"

    Note that VAX console adapters ("UART", "QUART") do not need to be loaded; they are preloaded.

  2. Mapping an object type to host resources: For example:

    load physical_serial_line TTA1
    set OPA0 line="/dev/ttyS1"

    In this example the object "physical_serial_line" is loaded, named "TTA1", and mapped to the "/dev/ttyS1" host physical serial port.

  3. Connect the loaded virtual line controller and the mapped object:

    set TXA line[5]=TTA1

    In this example, the 6th line of the DHV11 controller "TXA" loaded at step 1 is connected to the mapping object "TTA1" loaded at the step 2.

...

CHARON-VAX console ports can be configured to connect to an external terminal via the host system COM/TTY port or can be connected via TCP/IP.

 

ParameterTypeValue

rts[<line>]

Text string

  • "On" - assert RTS (Request To Send) signal

  • "Off" - clear RTS signal (default)

  • "DTR" - assert RTS signal as soon as DTR signal is asserted

dsr[<line>]

Text string

  • "On" - always reports DSR signal asserted

  • "Off" - always reports DSR signal deasserted

  • "DSR" - use DSR signal of physical serial line (if configured)

  • "CD", "DCD", "RLSD" - use CD (carrier detect) signal of physical serial line (if configured)

Info

This parameter is applicable only for line "2" of QUART.

communication [<line>]

Text string

  • "ASCII" - for connection to terminals  (default)

  • "BINARY" - for serial lines carrying binary (packet) protocols, which are used mainly for communicating with PLCs

line[<line>]

Identifier

This parameter is used to connect a particular serial line interface to the controller. See below for details.

Info

Note that the "line" parameter in the table above is applicable only in the case of QUART.

 

All the values in this table are case insensitive.

Back to Table of Contents 

Serial line controllers

Asynchronous serial line multiplexers are capable of serving up to 8 asynchronous serial lines (the DHW42-BA supports 16 lines).

The following asynchronous serial line multiplexers are supported:

 

VAX model

Asynchronous serial line emulation

MicroVAX II, MicroVAX 3600, MicroVAX 3900, VAXserver 3600, VAXserver 3900  (QBUS systems)

CXA16, CXB16, CXY08, DHQ11, DHV11, DZV11, DZQ11, DL11, DLV11, DZ11

MicroVAX 3100 - 96, MicroVAX 3100 - 98 (SCSI systems)

DHW42-AA, DHW42-BA, DHW42-CA

VAX4000 - 106, VAX4000 – 108, VAX4000 – 700, VAX4000 – 705 (QBUS/SCSI systems)

CXA16, CXB16, CXY08, DHQ11, DHV11, DZV11, DZQ11, DLV11, DHW42-AA, DHW42-BA, DHW42-CA

VAX6310, VAXstation 4090

N/A

 

The following names are used for the multiplexers:

 

Device name

Module name

DHV11

DHV11

DHQ11

DHV11

CXY08

DHV11

CXA16

DHV11

CXB16

DHV11

DHW42AA

DHV11

DHW42BA

DHV11

DHW42CA

DHV11

DZV11, DZ11

DZ11

DZQ11

DZ11

DL11, DLV11

DL11

 

The following example loads an instance of an asynchronous serial line multiplexer:

load DHQ11/DHV11 TXA
Warning

Only one instance of DHW42 can be loaded. There is no restriction on the number of the other multiplexers.

The multiplexers offer the following configuration parameters, specified with the "set" command:

 

Parameter

Type

Value

address

Numeric

Specifies CSR address. The address must be valid QBUS 22-bit wide address in I/O space.

Default values are 017760440 for DHV11-family controllers and 017760100 for DZV11/DZQ11, which are the factory settings for asynchronous serial line multiplexers.

Warning

 This parameter is not applicable to DHW42-xx serial line controllers

vector

Numeric

Specifies interrupt vector.

Default value is 0300 which is the factory setting for asynchronous serial line multiplexers. 

Warning

 This parameter is not applicable to DHW42-xx serial line controllers

line[N]

N=0…3(7,15)

Identifier

Specifies a name of the serial line interface object in configuration to which the N-th line of the multiplexer is connected. See below for details.

communication[N]

N=0…4(7,15)

Text String

  • "ASCII" - for connection to terminals  (default)

  • "BINARY" - for serial lines carrying binary (packet) protocols, which are used mainly for communicating with PLCs

rts[N]

N=0…3(7,15)

Text String

Controls RTS signal of the Nth line of the multiplexer. 

  • "On" - assert RTS (Request To Send) signal
  • "Off" - clear RTS signal (default)
  • "DTR" - assert RTS signal as soon as DTR signal is asserted

When left blank (initial state), the level of the RTS signal is as requested by the VAX software.

dsr[N]

N=0…3(7,15)

Text String

  • "On" - always reports DSR signal asserted
  • "Off" - always reports DSR signal deasserted
  • "DSR" - use DSR signal of physical serial line (if configured)
  • "CD", "DCD", "RLSD" - use CD (carrier detect) signal of physical serial line (if configured)
Info

This parameter is applicable only for DZV11 and DZQ11 serial lines controllers

 

 

tx_q_max_depth[N]

N=0…3(7,15)

Numeric

Specifies depth of the TX FIFO for the N-th line of the multiplexer. Possible values are 1…1000, initially it is set to 1 to properly represent the hardware limitation of certain multiplexers. Values greater than 1 improve transmission rate of corresponding line, but break correspondence to the original hardware.

Info

This parameter is applicable only for DHV11 serial lines controller

 

To load several instances of Qbus multiplexers, use the "address" and "vector" parameters. Both "address" and "vector" parameter values must be unique for every instance of a QBUS multiplexer.

Read the VAX hardware documentation and the VM system management documentation to understand how to correctly assign the "address" and "vector" parameters. 

Example of loading DHW42CA:

load DHW42CA/DHV11 TXA

.

Back to Table of Contents 

Mapping Serial line controllers to system resources

Types of serial line mapping

 

TypeFunction
physical_serial_line

This type of mapping associates some TTY port on host system with an emulated VAX serial line controller virtual "line".

The TTY port can be physical hardware port or a logical TTY port.

virtual_serial_lineThis type of mapping associates a network connection on the host system with an emulated VAX serial line controller virtual "line"
operator_consoleThis type of mapping associates the current TTY console with the OPA0 console port (if CHARON-VAX does not run as service)

Example:

load physical_serial_line OPA0

physical_serial_line

 

ParameterTypeDescription
lineText string

A defined TTY port on host system:

  • "/dev/tty<N>" - virtual serial lines

  • "/dev/ttyS<N>" - onboard serial lines

  • "/dev/ttyUSB<N>" - modem or usb serial lines adapters

baudNumeric

Forces the baud rate of the corresponding TTY port to a specified value.

The variety of supported values depends on the underlying physical communication resource (TTY port). The most widely used values are: 300, 1200, 9600, 19200, 38400.

Example:

set OPA0 baud=38400
break_onText string

Specifies what byte sequences received over the physical serial line will trigger a HALT command.

This parameter works only for the console line (for the one UART line and "line[3]" of QUART).

Specify the following values: "Crtl-P", "Break" or "none" ("none" disables triggering HALT condition).

Example:

set OPA0 break_on="Crtl-P"
stop_onText string

Specifies what byte sequences received over the physical serial line will trigger a STOP condition. The STOP condition causes CHARON-VAX to exit.

Specify the value as the following: “F6” or “none” ("none" disables triggering STOP condition).

Example:

set OPA0 stop_on="F6"

Setting "F6" triggers the STOP condition upon receipt of the "<ESC>[17~" sequence. Terminals usually send these sequences on pressing F6 button

logText string

A string specifying a file name to store content of console sessions or a directory where log files for each individual session will be stored.

If an existing directory is specified, CHARON-VAX automatically enables creation of individual log files for each session. If the "log" parameter is omitted, CHARON-VAX does not create a console log.

Examples:

set OPA0 log=”log.txt”
set OPA0 log=”/opt/charon/logs"

Example of mapping a console line to an onboard serial line:

load physical_serial_line OPA0
set OPA0 line="/dev/ttyS1"

virtual_serial_line

ParameterTypeDescription
hostText string

A remote host’s IP address or a host name (and optional remote TCP/IP port number) for the virtual serial line connection. If omitted, the virtual serial line does not initiate a connection to the remote host and will listen for incoming connection requests.

Specify the value in the following form:

set OPA0 host="<host-name>[:<port-no>]"

If "<port-no>" is not specified, the virtual serial line uses the TCP/IP port number specified by the "port" parameter (see below).

portNumeric

TCP/IP port number for the virtual serial line. A virtual serial line always listens on this port for incoming connection requests.

break_onText string

Specifies what byte sequences received over virtual serial line must trigger HALT command.

This parameter works only for console line (for CHARON-VAX it is the only line of UART and the "line[3]" of QUART).

Specify the following values: "Crtl-P", "Break" or "none" to disable triggering HALT condition.

Example:

set OPA0 break_on="Crtl-P"
stop_onText string

Specifies what byte sequences received over the virtual serial line will trigger a STOP condition. The STOP condition causes CHARON-VAX to exit.

Specify the value as the following: “F6” or “none” ("none" disables triggering STOP condition).

Example:

set OPA0 stop_on="F6"
logText string

A string specifying a file name to store content of console sessions or a directory where log files for each individual session will be stored.

If an existing directory is specified, CHARON-VAX automatically enables creation of individual log file for each session. If the "log" parameter is omitted CHARON-VAX does not create any console log.

Examples:

set OPA0 log=”log.txt”
set OPA0 log=”/opt/charon/logs"

Example of mapping a console line to an onboard serial line:

load virtual_serial_line OPA0
set OPA0 port=10003 stop_on="F6"

Notes on "virtual_serial_line" options:
 

Note that the examples above are mainly used for inter-CHARON communications. They are used to connect CHARON-VAX to an application that communicates to CHARON-VAX as described below.

 Example  console

console 

 

ParameterTypeDescription
break_on, stop_onText string

These two parameters are hardcoded to the following values and cannot be changed:

stop_on="F6"
break_on="Ctrl-P,F5"

 
   

 

Linking serial controller port to host connection

The final step of CHARON-VAX serial line configuration is the association of each loaded serial port with a CHARON-VAX host connection instance as follows:

set <serial controller instance name> line[<line number>]=<serial line instance name>
 

Example:

set quart line[0]=TTA0

 

 In