Introduction

To configure CHARON-VAX networking, follow these 3 steps:

  1. Load network adapter (if required)

    If you are configuring a DEQNA, DESQA, DELQA, DEUNA, DELUA, DEMNA, DEBNI or PMADAA adapter, use the "load" command as shown below. CHARON-VAX 3100/96/98 and 4000/106/108 emulations automatically load SGEC (with the name "eza") and therefore no "load" command is required.

    Example:

    load DELQA/DEQNA NIC


  2. Load "packet_port" or "tap_port" 

    Load "packet_port" or "tap_port" to connect the SGEC, DEQNA, DESQA, DELQA, DEUNA, DELUA, DEMNA, DEBNI or PMADAA adapter to the host hardware network card (or to a virtual network interface).

    Example:

    load packet_port/chnetwrk NDIS interface = "eth0"
    Divclass


  3. pagebreak

    Connect the loaded "packet_port" ("tap_port") to the loaded virtual network adapter

    Connect the SGEC, DEQNA, DESQA, DELQA, DEUNA, DELUA, DEMNA, DEBNI or PMADAA adapter to the "packet_port" ("tap_port") by setting the interface name.

    Example

    set NIC interface = NDIS


...

Include Page
KBCOMMON:DOC-GoToToc
KBCOMMON:DOC-GoToToc

Div
classpagebreak


SGEC Ethernet Controller

The built-in SGEC controller emulator ("eza") has the following parameters that are specified with the "set" command:

...