Introduction
To configure CHARON-VAX networking, follow these 3 steps:
Load network adapter (if required)
If you are configuring a DEQNA, DESQA, DELQA, DEUNA, DELUA, DEMNA, DEBNI or PMADAA adapter, use the "load" command as shown below. CHARON-VAX 3100/96/98 and 4000/106/108 emulations automatically load SGEC (with the name "eza") and therefore no "load" command is required.
Example:load DELQA/DEQNA NIC
Load "packet_port" or "tap_port"
Load "packet_port" or "tap_port" to connect the SGEC, DEQNA, DESQA, DELQA, DEUNA, DELUA, DEMNA, DEBNI or PMADAA adapter to the host hardware network card (or to a virtual network interface).
Example:load packet_port/chnetwrk NDIS interface = "eth0"
classDiv pagebreak Connect the loaded "packet_port" ("tap_port") to the loaded virtual network adapter
Connect the SGEC, DEQNA, DESQA, DELQA, DEUNA, DELUA, DEMNA, DEBNI or PMADAA adapter to the "packet_port" ("tap_port") by setting the interface name.
Example:set NIC interface = NDIS
...
Include Page | ||||
---|---|---|---|---|
|
Div | ||
---|---|---|
| ||
SGEC Ethernet Controller
The built-in SGEC controller emulator ("eza") has the following parameters that are specified with the "set" command:
...