Anchor | ||||
---|---|---|---|---|
|
Include Page | ||||
---|---|---|---|---|
|
...
The Charon-PAR/PA3 functionality of Charon-PAR emulates historic PA-RISC systems for MPE/iX. This section shows a sample installation of an MPE/iX guest system
Downloading and Unpacking the Provided MPE/IX Disk Container
...
Step | Description (configuration file settings are examples!) | |
---|---|---|
1 | Create a copy of the configuration file template. | Example:
|
2 | Open the configuration file in a text editor. |
or
|
3 | Configure the system model. | model "A400-100-110" |
4 | Configure the RAM for the emulated system. | memory 2G |
5 | Configure LDEV 1 (preconfigured system disk). | Change definition of DKA0 to:
|
6 | Configure a tape devices. | Change definition of MKAx to:
|
7 | Configure a network card based on a physical host NIC. This NIC is dedicated to the guest operating system and cannot be used for network communication by the host system. To share an interface, a virtual bridge would have to be used (see Ethernet configuration sections in this document). | In the configuration file template, comment out the dummy interface and the tap interface configuration. Then uncomment the interface configuration of the physical interface example. Change the definition of EWA0 to the interface that is assigned to the emulated system (example: eth1) and disable the offload parameters for the interface:
Depending on the capabilities of the Ethernet device, not all off-load offload parameters maybe be available. This will create a warning message. The variable IFACE is set by the system before executing the initialize command. For cloud environments, please note:
|
8 | Save the configuration file. |
...
Excerpt |
---|
Stromasys provides a special command file (SETIP.CHARON.SYS) in the preconfigured MPE image. This command file enables the user to configure the network without using a block-mode terminal that would otherwise be required to access the relevant MPE utility (NMMGR). The command file takes three parameters: host IP address, default gateway address, and netmask. The image below shows a sample: After changing the configuration, the command file will automatically restart the network to activate the changes. For cloud environments, please note: in case of a dedicated Ethernet interface, the IP address of the emulator must be set to the value assigned by the cloud provider to the corresponding host NIC. |
Div | ||
---|---|---|
| ||
Stopping the Emulator
...